Literature DB >> 19123703

Type of archwire and level of acidity: effects on the release of metal ions from orthodontic appliances.

Maja Kuhta1, Dubravko Pavlin, Martina Slaj, Suzana Varga, Marina Lapter-Varga, Mladen Slaj.   

Abstract

OBJECTIVE: To examine the effects of three different parameters-pH value, type of archwire, and length of immersion-on release of metal ions from orthodontic appliances.
MATERIALS AND METHODS: Simulated fixed orthodontic appliances that corresponded to one-half of the maxillary arch were immersed in artificial saliva of different pH values (6.75 +/- 0.15 and 3.5 +/- 0.15) during a 28-day period. Three types of archwires were used: stainless steel (SS), nickel-titanium (NiTi), and thermo NiTi. The quantity of metal ions was determined with the use of a high-resolution mass spectrophotometer (HR-ICP/MS).
RESULTS: The release of six different metal ions was observed: titanium (Ti), chromium (Cr), nickel (Ni), iron (Fe), copper (Cu), and zinc (Zn). Repeated measures statistical analysis of variance (ANOVA) was used. Results showed that (1) the appliances released measurable quantities of all ions examined; (2) the change in pH had a very strong effect (up to 100-fold) on the release of ions; and (3) the release of ions was dependent on wire composition, but it was not proportional to the content of metal in the wire. The largest number of ions was released during the first week of appliance immersion.
CONCLUSION: Levels of released ions are sufficient to cause delayed allergic reactions. This must be taken into account when type of archwire is selected, especially in patients with hypersensitivity or compromised oral hygiene.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19123703     DOI: 10.2319/083007-401.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  25 in total

1.  Release of metal ions from orthodontic appliances: an in vitro study.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Barbara Woźniak; Patrycja Downarowicz
Journal:  Biol Trace Elem Res       Date:  2011-10-20       Impact factor: 3.738

2.  Evaluation of corrosion behavior in artificial saliva of 2507 and 2205 duplex stainless steel for orthodontic wires before and after heat treatment.

Authors:  Ali Sabea Hammood; Ahmed Faraj Noor; Mohammed Talib Alkhafagy
Journal:  J Mater Sci Mater Med       Date:  2017-10-17       Impact factor: 3.896

3.  Estimation of Release of Nickel and Chromium by Indian Made Orthodontic Appliance in Saliva.

Authors:  Sandeep Parashar; Rajkumar Maurya; Ankur Gupta; Chatura Hegde; Neelima Anand
Journal:  J Clin Diagn Res       Date:  2015-09-01

4.  In vitro oxidative stress induced by conventional and self-ligating brackets.

Authors:  Zorana Ivankovic Buljan; Sonja Pezelj Ribaric; Maja Abram; Ante Ivankovic; Stjepan Spalj
Journal:  Angle Orthod       Date:  2011-09-13       Impact factor: 2.079

5.  An evaluation of two types of nickel-titanium wires in terms of micromorphology and nickel ions' release following oral environment exposure.

Authors:  Abdul Razzak A Ghazal; Mohammad Y Hajeer; Rabab Al-Sabbagh; Ibrahim Alghoraibi; Ahmad Aldiry
Journal:  Prog Orthod       Date:  2015-05-20       Impact factor: 2.750

6.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

7.  Effect of Mobile Phone Usage on Nickel Ions Release and pH of Saliva in Patients Undergoing Fixed Orthodontic Treatment.

Authors:  Lalita Girish Nanjannawar; Tejashree Suresh Girme; Jiwanasha Manish Agrawal; Manish Suresh Agrawal; Sangamesh Gurunath Fulari; Shraddha Subhash Shetti; Vishwal Ajith Kagi
Journal:  J Clin Diagn Res       Date:  2017-09-01

8.  Release of metal ions from fixed orthodontic appliance: an in vitro study in continuous flow system.

Authors:  Marcin Mikulewicz; Katarzyna Chojnacka; Paulina Wołowiec
Journal:  Angle Orthod       Date:  2013-03-11       Impact factor: 2.079

9.  Release of nickel and chromium ions in the saliva of patients with fixed orthodontic appliance: An in-vivo study.

Authors:  Anoop Dwivedi; Tripti Tikku; Rohit Khanna; Rana Pratap Maurya; Geeta Verma; R C Murthy
Journal:  Natl J Maxillofac Surg       Date:  2015 Jan-Jun

10.  Nickel Ion Release from Three Types of Nickel-titanium-based Orthodontic Archwires in the As-received State and After Oral Simulation.

Authors:  Barat Ali Ramazanzadeh; Farzaneh Ahrari; Berahman Sabzevari; Samaneh Habibi
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-06-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.