Literature DB >> 21913853

In vitro oxidative stress induced by conventional and self-ligating brackets.

Zorana Ivankovic Buljan1, Sonja Pezelj Ribaric, Maja Abram, Ante Ivankovic, Stjepan Spalj.   

Abstract

OBJECTIVE: To determine the in vitro oxidative stress induced by conventional and self-ligating brackets made of different materials.
MATERIALS AND METHODS: The concentration of oxidative stress marker 8-hydroxy-2'-deoxyguanosine (8-OHdG) in DNA of murine fibroblast cells L929 after in vitro exposure to three types of conventional and four types of self-ligating brackets was assessed. To determine viability and changes in the number of cells before and after exposure, trypan blue dye was used. Analysis of variance (ANOVA) was used for statistical analysis.
RESULTS: No significant difference in cell viability was noted between metal, ceramic, and polymeric conventional brackets, and self-ligating brackets made of combinations of those materials, but viability was significantly higher compared with positive controls (P < .05). The conventional sapphire ceramic bracket (Inspire Ice) showed high viability, the largest increase in the number of cells, and the lowest oxidative stress. A higher concentration of markers of oxidative stress was observed in full metal conventional and self-ligating brackets (MiniSprint and Speed) and in conventional polyurethane brackets (Quantum) compared with negative controls (P < .05).
CONCLUSION: All types of orthodontic brackets, regardless of the constituent materials, are a source of oxidative stress in vitro, but the highest stress was induced in the full metal and polyurethane brackets. Conventional ceramic brackets show the highest degree of biocompatibility compared with polymeric and metal brackets and self-ligating brackets made from combinations of these materials.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21913853      PMCID: PMC8867931          DOI: 10.2319/061811-395.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  30 in total

1.  In-vitro study of cellular viability and nitric oxide production by J774 macrophages stimulated by interferon gamma with ceramic, polycarbonate, and polyoxymethylene brackets.

Authors:  Julia Cristina de Andrade Vitral; Marcelo Reis Fraga; Maria Aparecida de Souza; Ana Paula Ferreira; Robert Willer Farinazzo Vitral
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-05       Impact factor: 2.650

Review 2.  In vivo aging of orthodontic alloys: implications for corrosion potential, nickel release, and biocompatibility.

Authors:  Theodore Eliades; Athanasios E Athanasiou
Journal:  Angle Orthod       Date:  2002-06       Impact factor: 2.079

Review 3.  Metals, oxidative stress and neurodegenerative disorders.

Authors:  Klaudia Jomova; Dagmar Vondrakova; Michael Lawson; Marian Valko
Journal:  Mol Cell Biochem       Date:  2010-08-22       Impact factor: 3.396

Review 4.  Systematic review of self-ligating brackets.

Authors:  Stephanie Shih-Hsuan Chen; Geoffrey Michael Greenlee; Jihyun-Elizabeth Kim; Craig L Smith; Greg J Huang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-06       Impact factor: 2.650

5.  Maternal nutrient supplementation counteracts bisphenol A-induced DNA hypomethylation in early development.

Authors:  Dana C Dolinoy; Dale Huang; Randy L Jirtle
Journal:  Proc Natl Acad Sci U S A       Date:  2007-08-01       Impact factor: 11.205

6.  In vivo determination of genotoxicity induced by metals from orthodontic appliances using micronucleus and comet assays.

Authors:  G H Westphalen; L M Menezes; D Prá; G G Garcia; V M Schmitt; J A P Henriques; R Medina-Silva
Journal:  Genet Mol Res       Date:  2008

Review 7.  Biocompatibility of nickel and cobalt dental alloys.

Authors:  N J Grimaudo
Journal:  Gen Dent       Date:  2001 Sep-Oct

Review 8.  Metals, toxicity and oxidative stress.

Authors:  M Valko; H Morris; M T D Cronin
Journal:  Curr Med Chem       Date:  2005       Impact factor: 4.530

9.  In vitro cytotoxicity of orthodontic primers.

Authors:  Vincenzo D'Antò; Gianrico Spagnuolo; Ilaria Polito; Sergio Paduano; Luigi Ambrosio; Rosa Valletta
Journal:  Prog Orthod       Date:  2009       Impact factor: 2.750

10.  In vivo study of metal content of oral mucosa cells in patients with and without fixed orthodontic appliances.

Authors:  F Amini; A Borzabadi Farahani; A Jafari; M Rabbani
Journal:  Orthod Craniofac Res       Date:  2008-02       Impact factor: 1.826

View more
  6 in total

1.  Evaluation of toxicity and response to oxidative stress generated by orthodontic bands in human gingival fibroblasts.

Authors:  Alexandre Marcos Bandeira; Elizabeth Ferreira Martinez; Ana Paula Dias Demasi
Journal:  Angle Orthod       Date:  2019-12-05       Impact factor: 2.079

2.  Evaluation of oxidative stress biomarkers in patients with fixed orthodontic appliances.

Authors:  Sevil Sema Atuğ Özcan; Ismail Ceylan; Erkan Ozcan; Nezahat Kurt; Ilhan Metin Dağsuyu; Cenk Fatih Canakçi
Journal:  Dis Markers       Date:  2014-04-10       Impact factor: 3.434

3.  Oxidative Stress Evaluation in Patients Treated with Orthodontic Self-ligating Multibracket Appliances: An in Vivo Case-Control Study.

Authors:  Marco Portelli; Angela Militi; Gabriele Cervino; Floriana Lauritano; Sergio Sambataro; Alberto Mainardi; Riccardo Nucera
Journal:  Open Dent J       Date:  2017-06-30

4.  In Vitro Determination of Genotoxicity Induced by Brackets Alloys in Cultures of Human Gingival Fibroblasts.

Authors:  Juan Pablo Loyola-Rodríguez; Ildelfonso Lastra-Corso; José Obed García-Cortés; Alejandra Loyola-Leyva; Rúben Abraham Domínguez-Pérez; David Avila-Arizmendi; Guillermo Contreras-Palma; Cecilia González-Calixto
Journal:  J Toxicol       Date:  2020-08-27

Review 5.  The Effect of Selected Dental Materials Used in Conservative Dentistry, Endodontics, Surgery, and Orthodontics as Well as during the Periodontal Treatment on the Redox Balance in the Oral Cavity.

Authors:  Izabela Zieniewska; Mateusz Maciejczyk; Anna Zalewska
Journal:  Int J Mol Sci       Date:  2020-12-18       Impact factor: 5.923

6.  Surface analysis of metal clips of ceramic self-ligating brackets.

Authors:  Kyung Sook Kim; Se Jik Han; Tae-Hee Lee; Tae-Joon Park; Samjin Choi; Yoon-Goo Kang; Ki-Ho Park
Journal:  Korean J Orthod       Date:  2018-12-19       Impact factor: 1.372

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.