Literature DB >> 19121822

Influence of different artificial disc kinematics on spine biomechanics.

Thomas Zander1, Antonius Rohlmann, Georg Bergmann.   

Abstract

BACKGROUND: There are several different artificial discs for the lumbar spine in clinical use. Though clinically established, little is known about the biomechanical advantages of different disc kinematics.
METHODS: A validated finite element model of the lumbosacral spine was used to compare the results of total disc arthroplasty at level L4/L5 performed by simulating the kinematics of three established artificial disc prostheses (Charité, ProDisc, Activ L). For flexion, extension, lateral bending, and axial torsion, the intervertebral rotations, the locations of the helical axes of rotation, the intradiscal pressures, and the facet joint forces were evaluated at the operated and adjacent levels.
FINDINGS: After insertion of an artificial disc, intervertebral rotation is reduced for flexion and increased for extension, lateral bending, and axial torsion for all studied discs at implant level. The positions of the helical axes are altered especially for lateral bending and axial torsion. Increased facet joint contact forces are predicted for the Charité disc during extension-- influenced by the existence of anterior scar tissue--and for the ProDisc and the Activ L during lateral bending and axial torsion. The studied artificial discs have only a minor effect on the adjacent levels. INTERPRETATIONS: For some load cases, total disc arthroplasty leads to considerably altered kinematics and increased facet joint contact forces at implant level. The spinal kinematic alterations due to an artificial disc exceed by far the inter-implant differences, while facet joint contact force alterations are strongly implant and load case dependent. The importance of implant kinematics is often overestimated.

Entities:  

Mesh:

Year:  2009        PMID: 19121822     DOI: 10.1016/j.clinbiomech.2008.11.008

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  18 in total

1.  Optimal stiffness of a pedicle-screw-based motion preservation implant for the lumbar spine.

Authors:  Antonius Rohlmann; Thomas Zander; Georg Bergmann; Hadi N Boustani
Journal:  Eur Spine J       Date:  2011-10-20       Impact factor: 3.134

2.  Morphometry of the lower lumbar intervertebral discs and endplates: comparative analyses of new MRI data with previous findings.

Authors:  Ruoliang Tang; Celal Gungor; Richard F Sesek; Kenneth Bo Foreman; Sean Gallagher; Gerard A Davis
Journal:  Eur Spine J       Date:  2016-02-12       Impact factor: 3.134

3.  Kinematic evaluation of one- and two-level Maverick lumbar total disc replacement caudal to a long thoracolumbar spinal fusion.

Authors:  Qingan Zhu; Eyal Itshayek; Claire F Jones; Timothy Schwab; Chadwick R Larson; Lawrence G Lenke; Peter A Cripton
Journal:  Eur Spine J       Date:  2012-04-25       Impact factor: 3.134

4.  Parameters influencing the outcome after total disc replacement at the lumbosacral junction. Part 1: misalignment of the vertebrae adjacent to a total disc replacement affects the facet joint and facet capsule forces in a probabilistic finite element analysis.

Authors:  A Rohlmann; S Lauterborn; M Dreischarf; H Schmidt; M Putzier; P Strube; T Zander
Journal:  Eur Spine J       Date:  2013-07-20       Impact factor: 3.134

5.  The effect of different design concepts in lumbar total disc arthroplasty on the range of motion, facet joint forces and instantaneous center of rotation of a L4-5 segment.

Authors:  Hendrik Schmidt; Stefan Midderhoff; Kyle Adkins; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2009-11       Impact factor: 3.134

6.  In silico evaluation of a new composite disc substitute with a L3-L5 lumbar spine finite element model.

Authors:  Jérôme Noailly; Luigi Ambrosio; K Elizabeth Tanner; Josep A Planell; Damien Lacroix
Journal:  Eur Spine J       Date:  2011-03-05       Impact factor: 3.134

7.  [Stiffening effect of a transsacral fusion system for the lumbosacral junction. A probabilistic finite element analysis and sensitivity study].

Authors:  H N Boustani; A Rohlmann; O Abouezzeddine; G Bergmann; T Zander
Journal:  Orthopade       Date:  2011-02       Impact factor: 1.087

8.  A probabilistic finite element analysis of the stresses in the augmented vertebral body after vertebroplasty.

Authors:  Antonius Rohlmann; Hadi Nabil Boustani; Georg Bergmann; Thomas Zander
Journal:  Eur Spine J       Date:  2010-04-02       Impact factor: 3.134

9.  Effect of multilevel lumbar disc arthroplasty on spine kinematics and facet joint loads in flexion and extension: a finite element analysis.

Authors:  Hendrik Schmidt; Fabio Galbusera; Antonius Rohlmann; Thomas Zander; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2010-04-02       Impact factor: 3.134

10.  Clinical, radiological, histological and retrieval findings of Activ-L and Mobidisc total disc replacements: a study of two patients.

Authors:  Shennah Austen; Ilona M Punt; Jack P M Cleutjens; Paul C Willems; Steven M Kurtz; Daniel W MacDonald; Lodewijk W van Rhijn; André van Ooij
Journal:  Eur Spine J       Date:  2012-01-15       Impact factor: 3.134

View more