Literature DB >> 19121502

Nickel concentration in the saliva of patients with nickel-titanium orthodontic appliances.

Evangelia Petoumenou1, Martin Arndt, Ludger Keilig, Susanne Reimann, Hildegard Hoederath, Theodore Eliades, Andreas Jäger, Christoph Bourauel.   

Abstract

INTRODUCTION: The purpose of this study was to examine whether nickel-titanium (Ni-Ti) archwires cause an increase of nickel concentration in the saliva of 18 orthodontic patients to estimate the possible risk of these archwires in patients who have nickel hypersensitivity.
METHODS: Saliva samples were collected before orthodontic treatment, after placement of the bands and brackets, 2 weeks later and before placing the Ni-Ti archwires, immediately after placing the Ni-Ti archwires, 4 weeks after placing the wires, and 8 weeks after placing the wires.
RESULTS: By using mass spectrometry, no statistically significant differences were found in the nickel concentrations in the samples taken without appliances, in those obtained 2 weeks after placement of the bands and brackets, and 4 and 8 weeks after placement of the archwires. Samples taken immediately after placement of the bands and brackets and the Ni-Ti archwires showed slight but significant increases in nickel concentration of 78 and 56 microg per liter, respectively, compared with the pretreatment value of 34 microg per liter.
CONCLUSIONS: Nickel leaching occurred after placement of the bands and brackets and after placement of the Ni-Ti archwires, associated with an increase of the nickel ion concentration in the patient's saliva. This effect decreased within 10 weeks.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19121502     DOI: 10.1016/j.ajodo.2006.12.018

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  23 in total

1.  Nickel ion concentrations in the saliva of patients treated with self-ligating fixed appliances: a prospective cohort study.

Authors:  Lina Gölz; Anna Christine Knickenberg; Ludger Keilig; Susanne Reimann; Spyridon N Papageorgiou; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-02-24       Impact factor: 1.938

2.  Resin monomers act as adjuvants in Ni-induced allergic dermatitis in vivo.

Authors:  K Bando; H Takahashi; M Kinbara; Y Tanaka; T Kuroishi; K Sasaki; T Takano-Yamamoto; S Sugawara; Y Endo
Journal:  J Dent Res       Date:  2014-09-24       Impact factor: 6.116

3.  Surface characterization of passive film and elemental release analysis of a Ni-Cr alloy during bleaching, part I: effects of different bleaching agents.

Authors:  Evşen Tamam; A Kevser Aydın
Journal:  Clin Oral Investig       Date:  2010-03-09       Impact factor: 3.573

4.  Nickel release from stainless steel and nickel titanium archwires - An in vitro study.

Authors:  Huma D Hussain; Sreedevi D Ajith; Prachi Goel
Journal:  J Oral Biol Craniofac Res       Date:  2016-07-02

Review 5.  [Metal implant sensitivity: clinical and histological presentation].

Authors:  D Hartmann; V Letulé; J J Schneider; M J Flaig
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

6.  Longitudinal assessment of periodontal status in patients with nickel allergy treated with conventional and nickel-free braces.

Authors:  Camila Alessandra Pazzini; Leandro Silva Marques; Maria Letícia Ramos-Jorge; Gilberto Oliveira Júnior; Luciano José Pereira; Saul Martins Paiva
Journal:  Angle Orthod       Date:  2011-11-01       Impact factor: 2.079

7.  In vitro oxidative stress induced by conventional and self-ligating brackets.

Authors:  Zorana Ivankovic Buljan; Sonja Pezelj Ribaric; Maja Abram; Ante Ivankovic; Stjepan Spalj
Journal:  Angle Orthod       Date:  2011-09-13       Impact factor: 2.079

8.  A Comparative Study of Biodegradation of Nickel and Chromium from Space Maintainers: An in vitro Study.

Authors:  Ashish Anand; Arun Sharma; Piush Kumar; Meera Sandhu; Shobhit Sachdeva; Vinod Sachdev
Journal:  Int J Clin Pediatr Dent       Date:  2015-04-28

Review 9.  Clinical usefulness of blood metal measurements to assess the failure of metal-on-metal hip implants.

Authors:  Barry Sampson; Alister Hart
Journal:  Ann Clin Biochem       Date:  2011-12-07       Impact factor: 2.057

10.  Evaluation of Nickel and Chromium Ion Release During Fixed Orthodontic Treatment Using Inductively Coupled Plasma-Mass Spectrometer: An In Vivo Study.

Authors:  Rabindra S Nayak; Bharti Khanna; Azam Pasha; K Vinay; Anjali Narayan; K Chaitra
Journal:  J Int Oral Health       Date:  2015-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.