Literature DB >> 19116852

Real-life step and activity measurement: reliability and validity.

M E Busse1, R W van Deursen, C M Wiles.   

Abstract

OBJECTIVES: Investigation of the reliability and validity of activity monitoring using a range of methods, namely manual counting, self report and two commercially available activity monitors. STUDY
DESIGN: Reliability, accuracy and validity study.
METHODS: Multiple convenience samples of healthy subjects were recruited to the study. Reliability of manual step count was determined using an intraclass correlation coefficient (ICC) (n = 10). Relationships between data from the Step Watch monitor (SAM) and (a) manual step counts (n = 18); (b) a second (different) activity monitor (ActivPAL); and (c) self reported activity levels (n = 22) were assessed using correlations. A Pearson's correlation and paired t-test was used to assess relations between routinely used monitors.
RESULTS: Intra-rater reliability for manual step counts was excellent (ICC 0.99), but inter-rater reliability was poor (ICC 0.26). Indoor accuracy of the SAM was 96.06% and outdoor accuracy was 99.58%. Moderate correlations (rho = 0.423 to 0.595, p < 0.05) were identified between the SAM monitor activity levels and self report diaries. The SAM and the ActivPAL were found to be internally reliable within themselves (ICC 0.96 and 0.95 respectively), significantly correlated (r = 0.93, p < 0.001) but also significantly different (t = 2.179, p < 0.05) when used simultaneously over the same circuit.
CONCLUSIONS: Activity monitors provide information that is related to actual activity and provide accurate and reliable data when tested on functional walking circuits. Activity monitors should not be used interchangeably due to the potential for systematic differences between the measurements obtained when applied simultaneously over the same repeated circuit.

Mesh:

Year:  2009        PMID: 19116852     DOI: 10.1080/03091900701682606

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  15 in total

Review 1.  Measurement of human energy expenditure, with particular reference to field studies: an historical perspective.

Authors:  Roy J Shephard; Yukitoshi Aoyagi
Journal:  Eur J Appl Physiol       Date:  2011-12-11       Impact factor: 3.078

Review 2.  Clinical outcomes assessment in clinical trials to assess treatment of femoroacetabular impingement: use of patient-reported outcome measures.

Authors:  Marcie Harris-Hayes; Christine M McDonough; Michael Leunig; Cara Beth Lee; John J Callaghan; Ewa M Roos
Journal:  J Am Acad Orthop Surg       Date:  2013       Impact factor: 3.020

3.  Which functional assessments predict long-term wear after total hip arthroplasty?

Authors:  Ryan K Takenaga; John J Callaghan; Nicholas A Bedard; Steve S Liu; Yubo Gao
Journal:  Clin Orthop Relat Res       Date:  2013-04-09       Impact factor: 4.176

4.  These Shoes Are Made for Walking: Sensitivity Performance Evaluation of Commercial Activity Monitors under the Expected Conditions and Circumstances Required to Achieve the International Daily Step Goal of 10,000 Steps.

Authors:  Sandra O'Connell; Gearóid ÓLaighin; Lisa Kelly; Elaine Murphy; Sorcha Beirne; Niall Burke; Orlaith Kilgannon; Leo R Quinlan
Journal:  PLoS One       Date:  2016-05-11       Impact factor: 3.240

5.  Indoor Tracking to Understand Physical Activity and Sedentary Behaviour: Exploratory Study in UK Office Buildings.

Authors:  Richard Spinney; Lee Smith; Marcella Ucci; Abigail Fisher; Marina Konstantatou; Alexia Sawyer; Jane Wardle; Alexi Marmot
Journal:  PLoS One       Date:  2015-05-20       Impact factor: 3.240

6.  Precision orthotics: optimising ankle foot orthoses to improve gait in patients with neuromuscular diseases; protocol of the PROOF-AFO study, a prospective intervention study.

Authors:  Niels F J Waterval; Frans Nollet; Jaap Harlaar; Merel-Anne Brehm
Journal:  BMJ Open       Date:  2017-02-28       Impact factor: 2.692

7.  Methods of Measurement in epidemiology: sedentary Behaviour.

Authors:  Andrew J Atkin; Trish Gorely; Stacy A Clemes; Thomas Yates; Charlotte Edwardson; Soren Brage; Jo Salmon; Simon J Marshall; Stuart J H Biddle
Journal:  Int J Epidemiol       Date:  2012-10       Impact factor: 7.196

8.  Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children.

Authors:  Saeideh Aminian; Erica A Hinckson
Journal:  Int J Behav Nutr Phys Act       Date:  2012-10-02       Impact factor: 6.457

9.  Variability of total step activity in children with cerebral palsy: influence of definition of a day on participant retention within the study.

Authors:  Nichola C Wilson; Suzie Mudge; N Susan Stott
Journal:  BMC Res Notes       Date:  2016-08-20

10.  Validity, reliability and feasibility of commercially available activity trackers in physical therapy for people with a chronic disease: a study protocol of a mixed methods research.

Authors:  Emmylou Beekman; Susy M Braun; Darcy Ummels; Kim van Vijven; Albine Moser; Anna J Beurskens
Journal:  Pilot Feasibility Stud       Date:  2017-11-23
View more