Literature DB >> 19107914

Retrospective correction for induced magnetic field inhomogeneity in measurements of large-vessel hemoglobin oxygen saturation by MR susceptometry.

Michael C Langham1, Jeremy F Magland, Tom F Floyd, Felix W Wehrli.   

Abstract

MR susceptometry-based blood oximetry relies on phase mapping to measure the difference in magnetic susceptibility between intravascular blood and surrounding tissue. The main source of error in MR susceptometry is the static field inhomogeneity caused by an interface between air and tissue or between adjacent tissue types. High-pass filtering has previously been used in conjunction with shimming to reduce the effect of low spatial-frequency modulations of the phase caused by large-scale induced magnetic fields. We demonstrate that high-pass filtering is not optimum for MR susceptometry because the results are sensitive to filter size. We propose an alternative method that acquires data without scanner-implemented default shimming, and fits, after appropriate weighting and masking, the static field inhomogeneity to a second-order polynomial. Compared to shimming the retrospective correction technique improved agreement between hemoglobin saturations measured in different segments of a vessel (femoral versus popliteal artery and vein) from three standard errors to less than one.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19107914      PMCID: PMC4743496          DOI: 10.1002/mrm.21499

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Artery and vein separation using susceptibility-dependent phase in contrast-enhanced MRA.

Authors:  Y Wang; Y Yu; D Li; K T Bae; J J Brown; W Lin; E M Haacke
Journal:  J Magn Reson Imaging       Date:  2000-11       Impact factor: 4.813

2.  MRI susceptometry: image-based measurement of absolute susceptibility of MR contrast agents and human blood.

Authors:  R M Weisskoff; S Kiihne
Journal:  Magn Reson Med       Date:  1992-04       Impact factor: 4.668

3.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

4.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

5.  In vivo measurement of tissue damage, oxygen saturation changes and blood flow changes after experimental traumatic brain injury in rats using susceptibility weighted imaging.

Authors:  Yimin Shen; Zhifeng Kou; Christian W Kreipke; Theodor Petrov; Jiani Hu; E Mark Haacke
Journal:  Magn Reson Imaging       Date:  2006-11-28       Impact factor: 2.546

Review 6.  The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds.

Authors:  J F Schenck
Journal:  Med Phys       Date:  1996-06       Impact factor: 4.071

7.  Correction of spatially dependent phase shifts for partial Fourier imaging.

Authors:  J R MacFall; N J Pelc; R M Vavrek
Journal:  Magn Reson Imaging       Date:  1988 Mar-Apr       Impact factor: 2.546

8.  Measurement of signal intensities in the presence of noise in MR images.

Authors:  R M Henkelman
Journal:  Med Phys       Date:  1985 Mar-Apr       Impact factor: 4.071

9.  Oxygen saturation as a screening test for critical congenital heart disease: a preliminary study.

Authors:  T R Hoke; P K Donohue; P K Bawa; R D Mitchell; A Pathak; P C Rowe; B J Byrne
Journal:  Pediatr Cardiol       Date:  2002 Jul-Aug       Impact factor: 1.655

Review 10.  Obstructive sleep apnea.

Authors:  Asher Qureshi; Robert D Ballard
Journal:  J Allergy Clin Immunol       Date:  2003-10       Impact factor: 10.793

View more
  39 in total

1.  Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification.

Authors:  Varsha Jain; Osheiza Abdulmalik; Kathleen Joy Propert; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  MRI estimation of global brain oxygen consumption rate.

Authors:  Varsha Jain; Michael C Langham; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2010-04-21       Impact factor: 6.200

3.  Quantitative oxygenation venography from MRI phase.

Authors:  Audrey P Fan; Berkin Bilgic; Louis Gagnon; Thomas Witzel; Himanshu Bhat; Bruce R Rosen; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

Review 4.  Susceptibility-based time-resolved whole-organ and regional tissue oximetry.

Authors:  Felix W Wehrli; Audrey P Fan; Zachary B Rodgers; Erin K Englund; Michael C Langham
Journal:  NMR Biomed       Date:  2016-02-26       Impact factor: 4.044

5.  Correction and optimization of a T2-based approach to map blood oxygenation in small cerebral veins.

Authors:  Lisa C Krishnamurthy; Deng Mao; Kevin S King; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2015-04-04       Impact factor: 4.668

6.  Method for rapid MRI quantification of global cerebral metabolic rate of oxygen.

Authors:  Suliman Barhoum; Michael C Langham; Jeremy F Magland; Zachary B Rodgers; Cheng Li; Chamith S Rajapakse; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2015-05-13       Impact factor: 6.200

Review 7.  Imaging brain oxygenation with MRI using blood oxygenation approaches: methods, validation, and clinical applications.

Authors:  T Christen; D S Bolar; G Zaharchuk
Journal:  AJNR Am J Neuroradiol       Date:  2012-08-02       Impact factor: 3.825

8.  High-speed whole-brain oximetry by golden-angle radial MRI.

Authors:  Wen Cao; Yulin V Chang; Erin K Englund; Hee Kwon Song; Suliman Barhoum; Zachary B Rodgers; Michael C Langham; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-03-25       Impact factor: 4.668

9.  In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

Authors:  Michael C Langham; Ana E Rodríguez-Soto; Nadav Schwartz; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-09-03       Impact factor: 4.668

Review 10.  Time-resolved MRI oximetry for quantifying CMRO(2) and vascular reactivity.

Authors:  Felix W Wehrli; Zachary B Rodgers; Varsha Jain; Michael C Langham; Cheng Li; Daniel J Licht; Jeremy Magland
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.