Literature DB >> 19106165

Can patients help with long-term total knee arthroplasty surveillance? Comparison of the American Knee Society Score self-report and surgeon assessment.

T J Gioe1, D Pomeroy, K Suthers, J A Singh.   

Abstract

OBJECTIVES: To compare patient self-report of knee flexion, extension, range of motion (ROM) and American Knee Society (AKS) Pain, Knee and Functional scores with a clinician assessment.
METHODS: A total of 239 consecutive total knee arthroplasty (TKA) patients (290 knees) were mailed surveys with an AKS questionnaire and lateral knee photographs that showed knee ROM in 10 degrees increments to compare their operated knee(s) ROM. Patients were subsequently seen in clinic and their ROM, AKS Pain, Knee and Functional scores were measured. Patient- and physician-reported measures were compared using independent sample t-test and correlated using Spearman's correlation coefficient. A priori rules for comparisons were based on previously published reports.
RESULTS: A total of 286 knees had both survey and clinic data available and constituted the analytic set. Patient-reported and physician-assessed extension, flexion and ROM were: 3 +/- 4.8 degrees vs 1.4 +/- 4.3 degrees (P < 0.001), 111.4 +/- 14.6 degrees vs 110 +/- 12.8 degrees (P = 0.04) and 108.6 +/- 16.8 vs 108.6 +/- 14.3 degrees (P = 0.98). There was a moderate correlation between patient and physician assessments (extension = 0.31; flexion = 0.44; ROM = 0.42; P < or = 0.001 for all). Patient-reported and physician-assessed AKS Pain, Knee and Functional scores were: 35.8 +/- 15.6 vs 43.9 +/- 11.1 (P < 0.001), 79.8 +/- 20 vs 88.9 +/- 13.3 (P < 0.001) and 57.7 +/- 23.1 vs 65.7 +/- 26.4 (P < 0.001), respectively. Patient- and physician-assessed AKS Pain, Knee and Functional scores had moderate-high correlation (r = 0.49, 0.49 and 0.70; P < or = 0.001 for all).
CONCLUSION: Long-term surveillance of TKA patients may be possible using a self-report AKS, but the average 8- to 10-point difference between patient- and physician-reported AKS scores (patients reporting poorer scores) represents a substantial impact on this outcome instrument. Since patient-reported responses have clear value in global assessment, further evaluation with other validated outcome instruments is warranted.

Entities:  

Mesh:

Year:  2008        PMID: 19106165      PMCID: PMC2722797          DOI: 10.1093/rheumatology/ken439

Source DB:  PubMed          Journal:  Rheumatology (Oxford)        ISSN: 1462-0324            Impact factor:   7.580


  33 in total

1.  How long should patients be followed-up after total hip replacement? Current practice in the UK.

Authors:  M J Bankes; R Coull; B D Ferris
Journal:  Ann R Coll Surg Engl       Date:  1999-09       Impact factor: 1.891

2.  Scoring systems in total knee arthroplasty.

Authors:  Christian Michael Bach; Michael Nogler; Iris Eva Steingruber; Michael Ogon; Cornelius Wimmer; Georg Göbel; Martin Krismer
Journal:  Clin Orthop Relat Res       Date:  2002-06       Impact factor: 4.176

Review 3.  Rating systems for total knee replacement.

Authors:  Andrew P Davies
Journal:  Knee       Date:  2002-12       Impact factor: 2.199

4.  Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions.

Authors:  L Brosseau; S Balmer; M Tousignant; J P O'Sullivan; C Goudreault; M Goudreault; S Gringras
Journal:  Arch Phys Med Rehabil       Date:  2001-03       Impact factor: 3.966

5.  Validity and responsiveness of the Knee Society Clinical Rating System in comparison with the SF-36 and WOMAC.

Authors:  E A Lingard; J N Katz; R J Wright; E A Wright; C B Sledge
Journal:  J Bone Joint Surg Am       Date:  2001-12       Impact factor: 5.284

6.  The Harris hip score: comparison of patient self-report with surgeon assessment.

Authors:  N N Mahomed; D C Arndt; B J McGrory; W H Harris
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

7.  Patient satisfaction after total knee arthroplasty: a comparison between subjective and objective outcome assessments.

Authors:  P H Bullens; C J van Loon; M C de Waal Malefijt; R F Laan; R P Veth
Journal:  J Arthroplasty       Date:  2001-09       Impact factor: 4.757

8.  Knee range of motion after total knee arthroplasty: how important is this as an outcome measure?

Authors:  Andrew L Miner; Elizabeth A Lingard; Elizabeth A Wright; Clement B Sledge; Jeffrey N Katz
Journal:  J Arthroplasty       Date:  2003-04       Impact factor: 4.757

9.  The Patient-Reported Outcomes Measurement Information System (PROMIS): progress of an NIH Roadmap cooperative group during its first two years.

Authors:  David Cella; Susan Yount; Nan Rothrock; Richard Gershon; Karon Cook; Bryce Reeve; Deborah Ader; James F Fries; Bonnie Bruce; Mattias Rose
Journal:  Med Care       Date:  2007-05       Impact factor: 2.983

10.  Functional rating for knee arthroplasty: comparison of three scoring systems.

Authors:  Raymond Y L Liow; Karen Walker; Mohammad A Wajid; Gurinder Bedi; Catherine M E Lennox
Journal:  Orthopedics       Date:  2003-02       Impact factor: 1.390

View more
  12 in total

1.  The potential utility of patient-reported range of motion after total knee arthroplasty.

Authors:  Jack Weick; Harpreet S Bawa
Journal:  Ann Transl Med       Date:  2015-08

2.  A comparison of patient-reported and measured range of motion in a cohort of total knee arthroplasty patients.

Authors:  Jamie E Collins; Benjamin N Rome; Meghan E Daigle; Vladislav Lerner; Jeffrey N Katz; Elena Losina
Journal:  J Arthroplasty       Date:  2014-02-26       Impact factor: 4.757

3.  Patients can accurately self-report their elbow range of motion following surgery for trauma.

Authors:  Vishal Palial; Han Hong Chong; Harvinder Singh
Journal:  J Clin Orthop Trauma       Date:  2021-11-27

4.  Postoperative alignment and ROM affect patient satisfaction after TKA.

Authors:  Shuichi Matsuda; Shinya Kawahara; Ken Okazaki; Yasutaka Tashiro; Yukihide Iwamoto
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

5.  Comparison of self-reported and measured range of motion in total knee arthroplasty patients.

Authors:  Bayram Unver; Abdurrahman Nalbant; Vasfi Karatosun
Journal:  Ann Transl Med       Date:  2015-08

6.  Responsiveness differences in outcome instruments after revision hip arthroplasty: what are the implications?

Authors:  Jasvinder A Singh
Journal:  BMC Musculoskelet Disord       Date:  2011-05-23       Impact factor: 2.362

7.  A High Proportion of Patients Have Unfulfilled Sexual Expectations After TKA: A Prospective Study.

Authors:  Rita Th E Harmsen; Tsjitske M Haanstra; Brenda L Den Oudsten; Hein Putter; Henk W Elzevier; Maaike G J Gademan; Rob G H H Nelissen
Journal:  Clin Orthop Relat Res       Date:  2020-09       Impact factor: 4.755

8.  Reliability of the "American Knee Society Score" (AKSS).

Authors:  Ana Luiza Cabrera Martimbianco; Fernanda Rizzo Calabrese; Luiz Alberto Nakao Iha; Marcelo Petrilli; Ozório Lira Neto; Mário Carneiro Filho
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

Review 9.  Assessment of chronic postsurgical pain after knee replacement: a systematic review.

Authors:  Vikki Wylde; Julie Bruce; Andrew Beswick; Karen Elvers; Rachael Gooberman-Hill
Journal:  Arthritis Care Res (Hoboken)       Date:  2013-11       Impact factor: 4.794

10.  Similar patient-reported outcomes and performance after total knee arthroplasty with or without patellar resurfacing.

Authors:  Abdulemir Ali; Anders Lindstrand; Anna Nilsdotter; Martin Sundberg
Journal:  Acta Orthop       Date:  2016-06       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.