Literature DB >> 11245764

Intra- and intertester reliability and criterion validity of the parallelogram and universal goniometers for measuring maximum active knee flexion and extension of patients with knee restrictions.

L Brosseau1, S Balmer, M Tousignant, J P O'Sullivan, C Goudreault, M Goudreault, S Gringras.   

Abstract

OBJECTIVE: To examine the intra- and intertester reliability of the universal goniometer (UG) and parallelogram goniometer (PG), and to assess the criterion validity of the same instruments on subjects with knee restrictions.
DESIGN: Reliability and validation study.
SETTING: Radiology department at university hospital. PARTICIPANTS: Sixty subjects (34 men, 26 women; mean age, 52yr) with various knee restrictions.
INTERVENTIONS: Sixteen goniometric measurements were collected per patient by 2 physical therapists. Subjects were evaluated in knee flexion and knee extension positions. To serve as a gold standard, radiographs were taken in both positions. MAIN OUTCOME MEASURES: Active knee flexion and knee extension on 2 goniometers, radiographs. Maximum active range of motion (AROM).
RESULTS: The UG intratester reliability (intraclass correlation coefficients [ICCs]) was .997 in flexion and .972 to .985 in extension. The results were also high with the PG (ICC =.996,.953-.955) for flexion and extension, respectively. The intertester reliability was high for flexion (ICC =.977-.982) and for extension (ICC =.893-.926) when using the UG. For the PG, ICC results ranged from .959 to .970 for flexion and from .856 to .898 for extension. Criterion validity (r) varied from .975 to .987 for flexion and from .390 to .442 for extension with the UG, and from .976 to .985 for flexion and .423 to .514 for extension with the PG.
CONCLUSION: Intra- and intertester reliability were high for both goniometers. The results for the criterion validity varied. Our study also revealed that it is preferable to use goniometry rather than visual estimations when measuring AROM. It is recommended that the same therapist take all the measurements when assessing AROM for UG and PG goniometric measurements on patients with knee restrictions.

Entities:  

Mesh:

Year:  2001        PMID: 11245764     DOI: 10.1053/apmr.2001.19250

Source DB:  PubMed          Journal:  Arch Phys Med Rehabil        ISSN: 0003-9993            Impact factor:   3.966


  51 in total

1.  Accuracy and inter-observer reliability of visual estimation compared to clinical goniometry of the elbow.

Authors:  Davide Blonna; Peter C Zarkadas; James S Fitzsimmons; Shawn W O'Driscoll
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-11-17       Impact factor: 4.342

2.  A comparison of patient-reported and measured range of motion in a cohort of total knee arthroplasty patients.

Authors:  Jamie E Collins; Benjamin N Rome; Meghan E Daigle; Vladislav Lerner; Jeffrey N Katz; Elena Losina
Journal:  J Arthroplasty       Date:  2014-02-26       Impact factor: 4.757

3.  Validity and reliability of using photography for measuring knee range of motion: a methodological study.

Authors:  Justine M Naylor; Victoria Ko; Sam Adie; Clive Gaskin; Richard Walker; Ian A Harris; Rajat Mittal
Journal:  BMC Musculoskelet Disord       Date:  2011-04-18       Impact factor: 2.362

4.  Clinical and radiologic outcomes of two patellar resection techniques during total knee arthroplasty: a prospective randomized controlled study.

Authors:  Fuzhen Yuan; Zewen Sun; Haijun Wang; Yourong Chen; Jiakuo Yu
Journal:  Int Orthop       Date:  2018-12-11       Impact factor: 3.075

5.  Computer-assisted navigation for the assessment of fixed flexion in knee arthroplasty.

Authors:  Price A M Gallie; Edward T Davis; Kelly Macgroarty; James P Waddell; Emil H Schemitsch
Journal:  Can J Surg       Date:  2010-02       Impact factor: 2.089

6.  Knee laxity measurements after anterior cruciate ligament reconstruction, using either bone-patellar-tendon-bone or hamstring tendon autografts, with special emphasis on comparison over time.

Authors:  Mattias Ahldén; Jüri Kartus; Lars Ejerhed; Jón Karlsson; Ninni Sernert
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-07-03       Impact factor: 4.342

7.  Therapeutic effects of prolotherapy with intra-articular dextrose injection in patients with moderate knee osteoarthritis: a single-arm study with 6 months follow up.

Authors:  Fariba Eslamian; Bahman Amouzandeh
Journal:  Ther Adv Musculoskelet Dis       Date:  2015-04       Impact factor: 5.346

8.  Effect of different postoperative flexion regimes on the outcomes of total knee arthroplasty: randomized controlled trial.

Authors:  Marcello De Fine; Francesco Traina; Gianluca Giavaresi; Eugenio Leo; Ilaria Sanzarello; Fabrizio Perna; Roberto Dattola; Cesare Faldini
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-04-07       Impact factor: 4.342

9.  Predictors of range of motion in patients undergoing manipulation after TKA.

Authors:  Harpreet S Bawa; Glenn D Wera; Matthew J Kraay; Randall E Marcus; Victor M Goldberg
Journal:  Clin Orthop Relat Res       Date:  2013-01       Impact factor: 4.176

10.  Is visual estimation of passive range of motion in the pediatric lower limb valid and reliable?

Authors:  Rami Rachkidi; Ismat Ghanem; Ibrahim Kalouche; Samer El Hage; Fernand Dagher; Khalil Kharrat
Journal:  BMC Musculoskelet Disord       Date:  2009-10-12       Impact factor: 2.362

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.