Literature DB >> 19097241

On using T2 to assess extrinsic magnetic field inhomogeneity effects on T2* measurements in myocardial siderosis in thalassemia.

Taigang He1, Gillian C Smith, Peter D Gatehouse, Raad H Mohiaddin, David N Firmin, Dudley J Pennell.   

Abstract

Magnetic resonance T(2)* has been validated as a noninvasive means of assessing myocardial iron overload. However, the effect on myocardial T(2)* of factors such as shimming, variations in capillary geometry, and susceptibility in relation to the effects of iron has not been fully clarified. Since T(2) is not affected by extrinsic magnetic field inhomogeneity and has different sensitivity to capillary geometry, investigation into the in vivo relationship between myocardial T(2)* and T(2) measurements can shed light on this important issue. This study was performed in 136 thalassemia patients. The myocardial T(2) and T(2)* thresholds for normality created identical no-iron-overload and iron-overloaded patient groups. In the no-iron group, there was no correlation between myocardial T(2) and T(2)*. In the iron-overloaded patients, there was a linear correlation (R(2) = 0.89) between myocardial T(2)* and T(2) measurements, which indicates that the iron deposition is the dominant factor in determining these two relaxation values in this scenario.

Entities:  

Mesh:

Year:  2009        PMID: 19097241     DOI: 10.1002/mrm.21874

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  Comparison of myocardial T1 and T2 values in 3 T with T2* in 1.5 T in patients with iron overload and controls.

Authors:  Gabriel C Camargo; Tamara Rothstein; Flavia P Junqueira; Elsa Fernandes; Andreas Greiser; Ralph Strecker; Viviani Pessoa; Ronaldo S L Lima; Ilan Gottlieb
Journal:  Int J Hematol       Date:  2016-02-12       Impact factor: 2.490

Review 2.  Cardiovascular magnetic resonance T2* for tissue iron assessment in the heart.

Authors:  Taigang He
Journal:  Quant Imaging Med Surg       Date:  2014-10

Review 3.  Cardiovascular Magnetic Resonance Parametric Mapping Techniques: Clinical Applications and Limitations.

Authors:  Eleni Nakou; Rishi K Patel; Marianna Fontana; Chiara Bucciarelli-Ducci
Journal:  Curr Cardiol Rep       Date:  2021-11-11       Impact factor: 2.931

4.  T1 and T2∗ relaxation time in the parcellated myocardium of healthy Taiwanese participants: A single center study.

Authors:  Chih-Chien Tsai; Shu-Hang Ng; Yao-Liang Chen; Yu-Hsiang Juan; Chao-Hung Wang; Gigin Lin; Chih-Wei Chien; Yu-Ching Lin; Yu-Chun Lin; Yu-Chieh Huang; Pei-Ching Huang; Jiun-Jie Wang
Journal:  Biomed J       Date:  2020-08-27       Impact factor: 7.892

Review 5.  Estimating tissue iron burden: current status and future prospects.

Authors:  John C Wood
Journal:  Br J Haematol       Date:  2015-03-12       Impact factor: 6.998

6.  Myocardial T2 quantitation in patients with iron overload at 3 Tesla.

Authors:  Hua Guo; Wing-Yan Au; Jerry S Cheung; Daniel Kim; Jens H Jensen; Pek-Lan Khong; Queenie Chan; Kevin C Chan; Christina Tosti; Haiying Tang; Truman R Brown; Wynnie W M Lam; Shau-Yin Ha; Gary M Brittenham; Ed X Wu
Journal:  J Magn Reson Imaging       Date:  2009-08       Impact factor: 4.813

Review 7.  Advances in parametric mapping with CMR imaging.

Authors:  Michael Salerno; Christopher M Kramer
Journal:  JACC Cardiovasc Imaging       Date:  2013-07

8.  Bright-blood T(2)-weighted MRI has high diagnostic accuracy for myocardial hemorrhage in myocardial infarction: a preclinical validation study in swine.

Authors:  Alexander R Payne; Colin Berry; Peter Kellman; Rachel Anderson; Li-Yueh Hsu; Marcus Y Chen; Allan R McPhaden; Stuart Watkins; William Schenke; Victor Wright; Robert J Lederman; Anthony H Aletras; Andrew E Arai
Journal:  Circ Cardiovasc Imaging       Date:  2011-09-19       Impact factor: 7.792

9.  Mapping iron in human heart tissue with synchrotron x-ray fluorescence microscopy and cardiovascular magnetic resonance.

Authors:  Michael J House; Adam J Fleming; Martin D de Jonge; David Paterson; Daryl L Howard; John-Paul Carpenter; Dudley J Pennell; Tim G St Pierre
Journal:  J Cardiovasc Magn Reson       Date:  2014-09-27       Impact factor: 5.364

10.  Validation of T2* in-line analysis for tissue iron quantification at 1.5 T.

Authors:  Mohammed H Alam; Taigang He; Dominique Auger; Gillian C Smith; Peter Drivas; Rick Wage; Cemil Izgi; Karen Symmonds; Andreas Greiser; Bruce S Spottiswoode; Lisa Anderson; David Firmin; Dudley J Pennell
Journal:  J Cardiovasc Magn Reson       Date:  2016-04-27       Impact factor: 5.364

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.