Literature DB >> 19096651

Computerized tomographic measurements of morphometric parameters of the c2 for the feasibility of laminar screw fixation in korean population.

Young-June Kim1, Woo Tack Rhee, Sang-Bok Lee, Seung-Hoon You, Sang-Youl Lee.   

Abstract

OBJECTIVE: C2 laminar screw fixation is considered as an excellent alternative to Magerl's transfacetal approach or Harms construct for the atlantoaxial stabilization. However, to our knowledge, there is no report on the feasibility of the new approach to Korean population. We investigated morphometric parameters of the dorsal arch of the C2 to provide the quantitative data for the feasibility of laminar screw fixation.
METHODS: One-hundred-and-two patients' cervical computed tomography had been reconstructed and investigated on the anatomical parameters related with C2 laminar screw placement. Sixty patients were male and forty-two patients were female. Measurements included the laminar thickness and slope, spino-laminar angle, and maximal screw length.
RESULTS: Ages ranged from 20 to 81 and the mean age was 48.4. Mean laminar thickness was 5.7 mm (+/-1.0) (5.8 mm in male and 5.4 mm in female). Fifty-one patients (50%) had a laminar thickness smaller than 5.5 mm at least unilaterally, therefore the patients were considered as inappropriate candidates for the laminar screw fixation in the smaller side of the laminae. Mean value of maximal length of screw was 33.3 mm (34.3 mm in male and 31.9 mm in female). Mean spino-laminar angle was 43.2 degrees and mean slope angle was 32.9 degrees .
CONCLUSION: Half of patients had inappropriate laminar profiles to accommodate a 3.5 mm screw in at least one side of the axis. The three-dimensional computed tomography reconstruction is mandatory for the preoperative assessment for the feasibility of the C2 lamina.

Entities:  

Keywords:  Axis; Laminar screw

Year:  2008        PMID: 19096651      PMCID: PMC2588282          DOI: 10.3340/jkns.2008.44.1.15

Source DB:  PubMed          Journal:  J Korean Neurosurg Soc        ISSN: 1225-8245


  16 in total

1.  Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation.

Authors:  Mohd Imran Yusof; Liau Kai Ming; Mohd Shafie Abdullah; Abdul Halim Yusof
Journal:  Spine (Phila Pa 1976)       Date:  2006-04-15       Impact factor: 3.468

2.  Anatomic considerations for the placement of C2 laminar screws.

Authors:  Ezequiel H Cassinelli; Michael Lee; Anthony Skalak; Nicholas U Ahn; Neill M Wright
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-15       Impact factor: 3.468

3.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance.

Authors:  Eric W Nottmeier; Andrew B Foy
Journal:  Eur Spine J       Date:  2007-11-22       Impact factor: 3.134

4.  In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation.

Authors:  Chandan Reddy; Aditya V Ingalhalikar; Scott Channon; Tae-Hong Lim; James Torner; Patrick W Hitchon
Journal:  J Neurosurg Spine       Date:  2007-10

5.  Application of laminar screws to posterior fusion of cervical spine: measurement of the cervical vertebral arch diameter with a navigation system.

Authors:  Kazuo Nakanishi; Masato Tanaka; Yoshihisa Sugimoto; Haruo Misawa; Tomoyuki Takigawa; Kazuo Fujiwara; Keiichiro Nishida; Toshifumi Ozaki
Journal:  Spine (Phila Pa 1976)       Date:  2008-03-15       Impact factor: 3.468

6.  Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation.

Authors:  Joseph Gorek; Emre Acaroglu; Sigurd Berven; Ahad Yousef; Christian M Puttlitz
Journal:  Spine (Phila Pa 1976)       Date:  2005-07-01       Impact factor: 3.468

7.  The anatomical suitability of the C1-2 complex for transarticular screw fixation.

Authors:  C G Paramore; C A Dickman; V K Sonntag
Journal:  J Neurosurg       Date:  1996-08       Impact factor: 5.115

Review 8.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons.

Authors:  N M Wright; C Lauryssen
Journal:  J Neurosurg       Date:  1998-04       Impact factor: 5.115

9.  Anatomic suitability of the C1-C2 complex for pedicle screw fixation.

Authors:  Daniel K Resnick; Samir Lapsiwala; Gregory R Trost
Journal:  Spine (Phila Pa 1976)       Date:  2002-07-15       Impact factor: 3.468

10.  Modified trajectory of c2 laminar screw - double bicortical purchase of the inferiorly crossing screw.

Authors:  Woo-Tack Rhee; Seung-Hoon You; Yeon-Gyu Jang; Sang-Youl Lee
Journal:  J Korean Neurosurg Soc       Date:  2008-02-20
View more
  7 in total

1.  Translaminar screw fixation of the cervical spine in Asian population: feasibility and safety consideration based on computerized tomographic measurements.

Authors:  Mohd Imran Yusof; Samir Shamsi Mohammed Shamsi
Journal:  Surg Radiol Anat       Date:  2011-09-21       Impact factor: 1.246

2.  Morphometric trajectory analysis for the C2 crossing laminar screw technique.

Authors:  Bin Yue; Dai-Soon Kwak; Moon-Kyu Kim; Seong-Oh Kwon; Seung-Ho Han
Journal:  Eur Spine J       Date:  2010-02-21       Impact factor: 3.134

3.  The anatomic and radiographic measurement of C2 lamina in Chinese population.

Authors:  Liu Xin-yu; Zhang Kai; Gong Laing-tai; Zheng Yan-ping; Li Jian-min
Journal:  Eur Spine J       Date:  2011-06-14       Impact factor: 3.134

Review 4.  Anatomical considerations of C2 lamina for the placement of translaminar screw: a review of the literature.

Authors:  D Chytas; D S Korres; G C Babis; N E Efstathopoulos; E C Papadopoulos; K Markatos; V S Nikolaou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08

5.  C2 anatomy for translaminar screw placement based on computerized tomographic measurements.

Authors:  Kriangsak Saetia; Anuchit Phankhongsab
Journal:  Asian Spine J       Date:  2015-04-15

6.  Morphometric Analysis and Classification of the Cross-Sectional Shape of the C2 Lamina.

Authors:  Soyeon Kim; Dai-Soon Kwak; In-Beom Kim
Journal:  Biomed Res Int       Date:  2017-09-25       Impact factor: 3.411

7.  Morphometry of the C2 Pedicle and Lamina in Thai Patients.

Authors:  Pakorn Yuwakosol; Thakul Oearsakul; Thara Tunthanathip
Journal:  Asian J Neurosurg       Date:  2020-02-25
  7 in total