Literature DB >> 21947622

Translaminar screw fixation of the cervical spine in Asian population: feasibility and safety consideration based on computerized tomographic measurements.

Mohd Imran Yusof1, Samir Shamsi Mohammed Shamsi.   

Abstract

PURPOSE: Cervical translaminar screw fixation has been shown to be safe, efficient and provides alternative for cervical fixation. However, its use in the Asian population should be considered cautiously because the cervical lamina diameter may not be adequate to accommodate the standard lamina screw size. We studied the average transverse lamina diameter of the cervical spine in the Malaysian population to evaluate the feasibility and safety of lamina screw fixation in this population.
METHODS: The measurements of the cervical lamina were performed on CT images. The diameters were defined as the most inner or outer diameter of the lamina, taken perpendicular to the axis of the lamina and measured in millimeters up to 0.1 mm.
RESULTS: The mean transverse inner diameter of the lamina of C2, C3, C4, C5, C6 and C7 was 3.4, 2.0, 1.7, 1.9, 2.3 and 3.4 mm, respectively. The lamina of C2 and C7 has the largest transverse inner diameter and the lamina of C4 the smallest. The mean transverse outer diameter of the lamina of C2, C3, C4, C5, C6 and C7 was 5.6, 3.5, 3.1, 3.1, 3.9 and 5.8 mm, respectively. The lamina of C7 has the largest transverse outer diameter and the lamina of C4 and C5 the smallest.
CONCLUSIONS: Translaminar fixation using a 3.5 screw should be attempted with caution in Asian population. Pre-operative CT scan evaluation is mandatory before translaminar screw fixation is attempted.

Mesh:

Year:  2011        PMID: 21947622     DOI: 10.1007/s00276-011-0869-8

Source DB:  PubMed          Journal:  Surg Radiol Anat        ISSN: 0930-1038            Impact factor:   1.246


  27 in total

1.  Thoracic pedicle screw insertion in Asian cadaveric specimen: does radiological pedicle profile affect outcome?

Authors:  Chris Yin Wei Chan; Mun Keong Kwan; Lim Beng Saw
Journal:  Surg Radiol Anat       Date:  2010-09-17       Impact factor: 1.246

2.  Predicted cervical canal enlargement and effective cord decompression following expansive laminoplasty using cervical magnetic resonance imaging.

Authors:  Mohd Imran Yusof; Eskandar Hassan; Shafie Abdullah
Journal:  Surg Radiol Anat       Date:  2010-07-24       Impact factor: 1.246

3.  Computerized tomographic measurement of the cervical pedicles diameter in a Malaysian population and the feasibility for transpedicular fixation.

Authors:  Mohd Imran Yusof; Liau Kai Ming; Mohd Shafie Abdullah; Abdul Halim Yusof
Journal:  Spine (Phila Pa 1976)       Date:  2006-04-15       Impact factor: 3.468

4.  Anatomic considerations for the placement of C2 laminar screws.

Authors:  Ezequiel H Cassinelli; Michael Lee; Anthony Skalak; Nicholas U Ahn; Neill M Wright
Journal:  Spine (Phila Pa 1976)       Date:  2006-11-15       Impact factor: 3.468

5.  In vitro biomechanical comparison of transpedicular versus translaminar C-2 screw fixation in C2-3 instrumentation.

Authors:  Chandan Reddy; Aditya V Ingalhalikar; Scott Channon; Tae-Hong Lim; James Torner; Patrick W Hitchon
Journal:  J Neurosurg Spine       Date:  2007-10

6.  The terminal insertional segments and communications of the vertebral nerve in the human cervical region.

Authors:  J Yan; K Ogino; J Hitomi
Journal:  Surg Radiol Anat       Date:  2008-10-07       Impact factor: 1.246

7.  Accuracy and complications of transpedicular C2 screw placement without the use of spinal navigation.

Authors:  Christian-Andreas Mueller; Lukas Roesseler; Martin Podlogar; Attlila Kovacs; Rudolf Andreas Kristof
Journal:  Eur Spine J       Date:  2010-02-06       Impact factor: 3.134

8.  Cervical venous organization in the transverse foramen.

Authors:  Olivier Palombi; Stephane Fuentes; Philippe Chaffanjon; Jean-Guy Passagia; Jean-Paul Chirossel
Journal:  Surg Radiol Anat       Date:  2005-09-30       Impact factor: 1.246

9.  Significance of laminar screw fixation in the subaxial cervical spine.

Authors:  Jae Taek Hong; Jae Hoon Sung; Byung Chul Son; Sang Won Lee; Chun Kun Park
Journal:  Spine (Phila Pa 1976)       Date:  2008-07-15       Impact factor: 3.468

10.  Use of axial and subaxial translaminar screw fixation in the management of upper cervical spinal instability in a series of 7 children.

Authors:  Roukoz B Chamoun; Katherine M Relyea; Keyne K Johnson; William E Whitehead; Daniel J Curry; Thomas G Luerssen; James M Drake; Andrew Jea
Journal:  Neurosurgery       Date:  2009-04       Impact factor: 4.654

View more
  11 in total

Review 1.  Use of intraoperative fluoroscopy for the safe placement of C2 laminar screws: technical note.

Authors:  John A Engler; Michael L Smith
Journal:  Eur Spine J       Date:  2015-08-05       Impact factor: 3.134

2.  Morphometry of typical cervical vertebrae on dry bones and CT scan and its implications in transpedicular screw placement surgery.

Authors:  Richa Gupta; Kanchan Kapoor; Anshu Sharma; Suman Kochhar; Rajeev Garg
Journal:  Surg Radiol Anat       Date:  2012-09-09       Impact factor: 1.246

Review 3.  Anatomical considerations of C2 lamina for the placement of translaminar screw: a review of the literature.

Authors:  D Chytas; D S Korres; G C Babis; N E Efstathopoulos; E C Papadopoulos; K Markatos; V S Nikolaou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-11-08

4.  Morphological study of the posterior osseous structures of subaxial cervical spine in a population from northeastern China.

Authors:  Zhenyu Wang; Jiali Leng; Jianhua Liu; Yi Liu
Journal:  J Orthop Surg Res       Date:  2015-04-21       Impact factor: 2.359

5.  Feasibility of translaminar screw placement in Korean population: morphometric analysis of cervical spine.

Authors:  Gyu Yeul Ji; Chang Hyun Oh; Sang Hyuk Park; Ferry Kurniawan; Junho Lee; Jae Kyun Jeon; Dong Ah Shin; Keung Nyun Kim
Journal:  Yonsei Med J       Date:  2015-01       Impact factor: 2.759

6.  C2 anatomy for translaminar screw placement based on computerized tomographic measurements.

Authors:  Kriangsak Saetia; Anuchit Phankhongsab
Journal:  Asian Spine J       Date:  2015-04-15

7.  The risk of translaminar screw fixation to the transverse foramen of the lower cervical spine: a computed tomography study.

Authors:  Ganggang Kong; Wei Ji; Zucheng Huang; Junhao Liu; Jianting Chen; Qingan Zhu
Journal:  Sci Rep       Date:  2017-04-21       Impact factor: 4.379

8.  Morphometric Analysis and Classification of the Cross-Sectional Shape of the C2 Lamina.

Authors:  Soyeon Kim; Dai-Soon Kwak; In-Beom Kim
Journal:  Biomed Res Int       Date:  2017-09-25       Impact factor: 3.411

9.  Feasibility of bilateral crossing c7 intralaminar screws: a cadaveric study.

Authors:  Tae-Hyun Baek; Ilsup Kim; Jae-Taek Hong; Daniel H Kim; Dongsuk Shin; Sang-Won Lee
Journal:  J Korean Neurosurg Soc       Date:  2014-07-31

10.  Feasibility of C2 Vertebra Screws Placement in Patient With Occipitalization of Atlas: A Tomographic Study.

Authors:  Wei Ji; Xiang Liu; Wenhan Huang; Zucheng Huang; Xueshi Li; Jianting Chen; Zenghui Wu; Qingan Zhu
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.