Literature DB >> 19089465

Postoperative aseptic osteonecrosis in a case of kyphoplasty.

Michael Mueller1, M Daniels-Wredenhagen, L Besch, C Decher, A Seekamp.   

Abstract

Aseptic osteonecrosis appears to be an infrequent adverse event after kyphoplasty which has not previously been reported. In the following, we present the case of a 73-year-old female who sustained a compression fracture of the first lumbar vertebra (L1) in a motor vehicle accident. The fracture was treated by kyphoplasty using PMMA cement. Three weeks after hospital discharge the patient was presented with increasing back pain. In imaging, dislocation of the PMMA cement could be shown combined with a total collapse of the L1 vertebra. The resulting significant kyphosis was first reduced by dorsal transpedicular (Th12-L2) internal fixation and stabilized by an anterior cage after total removal of the cement plomb and some remaining bone of the L1 vertebra. Bacterial as well as histological examination of the cement and bone led to the diagnosis of aseptic osteonecrosis. Different underlying events could be discussed. We think it most likely that the osteoporotic bone was unable to interface sufficiently with the PMMA cement and, therefore, disintegrated under loading. Furthermore, the volume of injected cement could have significantly compromised the blood supply within the bone.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19089465      PMCID: PMC2899564          DOI: 10.1007/s00586-008-0843-2

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  13 in total

1.  Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty.

Authors:  M A Liebschner; W S Rosenberg; T M Keaveny
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

2.  New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures.

Authors:  S R Garfin; H A Yuan; M A Reiley
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

3.  Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures.

Authors:  I H Lieberman; S Dudeney; M K Reinhardt; G Bell
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

4.  The biomechanics of vertebroplasty. The effect of cement volume on mechanical behavior.

Authors:  S M Belkoff; J M Mathis; L E Jasper; H Deramond
Journal:  Spine (Phila Pa 1976)       Date:  2001-07-15       Impact factor: 3.468

5.  Biomechanical evaluation of vertebroplasty and kyphoplasty with polymethyl methacrylate or calcium phosphate cement under cyclic loading.

Authors:  Hans-Joachim Wilke; Ulrich Mehnert; Lutz E Claes; Michael M Bierschneider; Hans Jaksche; Bronek M Boszczyk
Journal:  Spine (Phila Pa 1976)       Date:  2006-12-01       Impact factor: 3.468

6.  Vertebral fractures and mortality in older women: a prospective study. Study of Osteoporotic Fractures Research Group.

Authors:  D M Kado; W S Browner; L Palermo; M C Nevitt; H K Genant; S R Cummings
Journal:  Arch Intern Med       Date:  1999-06-14

7.  Reduced pulmonary function in patients with spinal osteoporotic fractures.

Authors:  C Schlaich; H W Minne; T Bruckner; G Wagner; H J Gebest; M Grunze; R Ziegler; G Leidig-Bruckner
Journal:  Osteoporos Int       Date:  1998       Impact factor: 4.507

8.  Histologic evaluation of human vertebral bodies after vertebral augmentation with polymethyl methacrylate.

Authors:  Daisuke Togawa; Thomas W Bauer; Isador H Lieberman; Satoshi Takikawa
Journal:  Spine (Phila Pa 1976)       Date:  2003-07-15       Impact factor: 3.468

9.  Population-based study of survival after osteoporotic fractures.

Authors:  C Cooper; E J Atkinson; S J Jacobsen; W M O'Fallon; L J Melton
Journal:  Am J Epidemiol       Date:  1993-05-01       Impact factor: 4.897

10.  Percutaneous vertebroplasty for osteolytic metastases and myeloma: effects of the percentage of lesion filling and the leakage of methyl methacrylate at clinical follow-up.

Authors:  A Cotten; F Dewatre; B Cortet; R Assaker; D Leblond; B Duquesnoy; P Chastanet; J Clarisse
Journal:  Radiology       Date:  1996-08       Impact factor: 11.105

View more
  4 in total

1.  What is the importance of "halo" phenomenon around bone cement following vertebral augmentation for osteoporotic compression fracture?

Authors:  K H Kim; S U Kuh; J Y Park; K S Kim; D K Chin; Y E Cho
Journal:  Osteoporos Int       Date:  2012-01-21       Impact factor: 4.507

2.  Prevention and treatment of bone cement-related complications in patients receiving percutaneous kyphoplasty.

Authors:  Kaining Zhang; Yingchun Shen; Yanjun Ren; Debo Zou
Journal:  Int J Clin Exp Med       Date:  2015-02-15

Review 3.  Current status and challenges of percutaneous vertebroplasty (PVP).

Authors:  Tomoyuki Noguchi; Koji Yamashita; Ryotaro Kamei; Junki Maehara
Journal:  Jpn J Radiol       Date:  2022-08-09       Impact factor: 2.701

4.  Bone Cement Dislodgement: One of Complications Following Bone Cement Augmentation Procedures for Osteoporotic Spinal Fracture.

Authors:  Kee-Yong Ha; Young-Hoon Kim; Sung-Rim Yoo; Jan Noel Molon
Journal:  J Korean Neurosurg Soc       Date:  2015-05-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.