Literature DB >> 19074920

Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes.

G Bencic1, Z Vatavuk, M Marotti, V L Loncar, I Petric, B Andrijevic-Derk, J Skunca, Z Mandic.   

Abstract

AIMS: The aim of the study was to compare the accuracy of A-scan biometry and MRI for the measurement of axial length in silicone oil-filled eyes.
METHODS: This was a prospective randomised study of 70 patients. Biometry was performed using MRI in 33 patients (MRI group) and A-scan echography in 37 patients (A-scan group). The difference between predicted and final refraction was measured and evaluated statistically.
RESULTS: In patients with axial length >/=26 mm, the mean deviation of the final from predicted refraction was -1.23 (SD 0.67) D in the MRI group and -2.3 (SD 2.02) D in the A-scan group. The difference between these two groups was statistically significant (p = 0.02). In patients with axial length <26 mm, the mean deviation of the final from predicted refraction was -0.12 (SD 1.29) D in the MRI group and -0.33 (SD 1.39) D in the A-scan group. There was no statistical significance between the two groups (p = 0.629).
CONCLUSION: For highly myopic patients MRI biometry was a more accurate measurement of axial length in silicone oil-filled eyes. A-scan and MRI biometry were comparably accurate in measuring axial length in patients with axial length <26 mm.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19074920     DOI: 10.1136/bjo.2008.147868

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  5 in total

1.  Accuracy and reliability of IOL master and A-scan immersion biometry in silicone oil-filled eyes.

Authors:  P Kunavisarut; P Poopattanakul; C Intarated; K Pathanapitoon
Journal:  Eye (Lond)       Date:  2012-08-10       Impact factor: 3.775

2.  Rectus Extraocular Muscle Paths and Staphylomata in High Myopia.

Authors:  Yunping Li; Qi Wei; Alan Le; Bola Ayoub Gawargious; Joseph L Demer
Journal:  Am J Ophthalmol       Date:  2019-02-04       Impact factor: 5.258

3.  Heavy eye syndrome versus sagging eye syndrome in high myopia.

Authors:  Roland Joseph D Tan; Joseph L Demer
Journal:  J AAPOS       Date:  2015-12       Impact factor: 1.220

4.  Reproducibility of a long-range swept-source optical coherence tomography ocular biometry system and comparison with clinical biometers.

Authors:  Ireneusz Grulkowski; Jonathan J Liu; Jason Y Zhang; Benjamin Potsaid; Vijaysekhar Jayaraman; Alex E Cable; Jay S Duker; James G Fujimoto
Journal:  Ophthalmology       Date:  2013-06-04       Impact factor: 12.079

5.  Characterization of the position of the extraocular muscles and orbit in acquired esotropia both at distance and near using orbital magnetic resonance imaging.

Authors:  Manami Kawai; Toshiaki Goseki; Hitoshi Ishikawa; Sonoko Tatsui; Hongyang Li; Ryutaro Ukisu; Nobuyuki Shoji
Journal:  PLoS One       Date:  2021-03-12       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.