Literature DB >> 19073958

The effect of force, timing, and location on bone-to-implant contact of miniscrew implants.

P W Woods1, P H Buschang, S E Owens, P E Rossouw, L A Opperman.   

Abstract

This study was conducted to evaluate the effect of timing and force of loading, as well as implant location, on bone-to-implant contact (BIC) of loaded and control miniscrew implants (MSI). Using seven skeletally mature male beagle dogs, 1-2 years of age, followed over a 110 day period, a randomized split-mouth design compared immediate versus delayed loading, 50 versus 25 g loading, and 25 g loads in the maxilla versus the mandible. Mobility was evaluated using a 0-3 point scale before the MSIs were prepared for histological analysis. Histomorphometric analyses were performed under light microscopy using Metamorph software on undecalcified sections. The percentage BIC was measured at three levels (coronal, middle, and apical) of the MSI. BIC was compared statistically using pairwise Wilcoxon signed-rank tests. Mobility was detected in three of the 56 (5.4 per cent) MSIs. The mobile implants were all unloaded controls and showed no BIC. All remaining stable MSIs showed some BIC. However, variation in BIC was large, ranging from 2.2 to 100 per cent. There were no significant (P > 0.05) differences in BIC associated with timing of force application, amount of force applied, or implant location. There was a tendency for less BIC at the coronal level, but the differences between levels were not statistically significant. Within the limits of this study, it is concluded that the timing and amount of force at loading and location of implant placement do not affect BIC. Moreover, it appears that only limited amounts of osseointegration are necessary to ensure implant stability.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19073958     DOI: 10.1093/ejo/cjn091

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  9 in total

1.  Orthodontic Microimplants Assisted Intrusion of Supra-erupted Maxillary Molar Enabling Osseointegrated Implant Supported Mandibular Prosthesis: Case Reports.

Authors:  Deepak Rai; Saranjeet Singh Bhasin; Sheetal Rai
Journal:  J Indian Prosthodont Soc       Date:  2013-08-02

2.  [Uprighting a mesially tilted mandibular second molar by using a dental implant as anchorage: a case report].

Authors:  Jie Zhou; Xue-Qi Gan; Jia-Yi Lu; Lin-Li Fan; Zhuo-Li Zhu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2020-12-01

3.  Direct versus indirect loading of orthodontic miniscrew implants-an FEM analysis.

Authors:  C Holberg; P Winterhalder; N Holberg; I Rudzki-Janson; A Wichelhaus
Journal:  Clin Oral Investig       Date:  2012-10-31       Impact factor: 3.573

4.  Comparison of BALP, CTX-I, and IL-4 levels around miniscrew implants during orthodontic tooth movement between two different amounts of force.

Authors:  Mine Gecgelen Cesur; V Ozgen Ozturk; Beral Afacan; F Burcu Sirin; Afra Alkan; Torun Ozer
Journal:  Angle Orthod       Date:  2019-02-07       Impact factor: 2.079

5.  Levels of TGF-β1 in peri-miniscrew implant crevicular fluid.

Authors:  Avinash Kaur; Om Prakash Kharbanda; Moganty R Rajeswari; Dinesh Kalyanasundaram
Journal:  J Oral Biol Craniofac Res       Date:  2020-03-06

6.  Biomechanical Effects of Various Bone-Implant Interfaces on the Stability of Orthodontic Miniscrews: A Finite Element Study.

Authors:  Fabing Tan; Chao Wang; Chongshi Yang; Yuanding Huang; Yubo Fan
Journal:  J Healthc Eng       Date:  2017-06-19       Impact factor: 2.682

7.  A study of interleukin 1β levels in peri-miniscrew crevicular fluid (PMCF).

Authors:  Nitika Monga; Sushma Chaurasia; Om Prakash Kharbanda; Ritu Duggal; Moganty Raja Rajeswari
Journal:  Prog Orthod       Date:  2014-04-01       Impact factor: 2.750

8.  Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

Authors:  Barat Ali Ramazanzadeh; Kazem Fatemi; Mahboobe Dehghani; Nooshin Mohtasham; Arezoo Jahanbin; Hamed Sadeghian
Journal:  ISRN Dent       Date:  2014-04-06

9.  Histomorphometric evaluation of the bone surrounding orthodontic miniscrews according to their adjacent root proximity.

Authors:  Hyun-Ju Oh; Jung-Yul Cha; Hyung-Seog Yu; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2018-08-08       Impact factor: 1.372

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.