Literature DB >> 26199523

Orthodontic Microimplants Assisted Intrusion of Supra-erupted Maxillary Molar Enabling Osseointegrated Implant Supported Mandibular Prosthesis: Case Reports.

Deepak Rai1, Saranjeet Singh Bhasin2, Sheetal Rai3.   

Abstract

Loss of mandibular molars, when not replaced in time, are usually associated with overeruption of maxillary molars. To provide prosthetic replacement for missing lower posteriors, over erupted maxillary teeth have been intruded in past with great difficulty in adults with conventional orthodontics, along with associated problems of root resorption. Currently orthodontic microimplants provide stable intraoral anchorage, allow predictable maxillary molar intrusion enabling reestablishment of functional posterior occlusion with mandibular implant supported prosthesis, thereby reducing need for prosthetic crown reduction in maxillary arch. The added advantage of microimplant is it enables use of sectional appliance in area of concern instead of full arch bracketed appliance which an adult may not accept. The case reports demonstrates, overerupted maxillary molars were intruded using orthodontic microimplants to enable prosthetic rehabilitation of mandibular dentition by osseointegrated implant supported prosthesis. The second case report also demonstrates use of CBCT scan in planning and execution.

Keywords:  Molar intrusion; Orthodontic microimplant; Osseointegrated implants; Supraeruption

Year:  2013        PMID: 26199523      PMCID: PMC4501992          DOI: 10.1007/s13191-013-0306-2

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  16 in total

1.  Closing anterior open bites by intruding molars with titanium miniplate anchorage.

Authors:  Keith H Sherwood; James G Burch; William J Thompson
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-12       Impact factor: 2.650

2.  Factors affecting the clinical success of screw implants used as orthodontic anchorage.

Authors:  Hyo-Sang Park; Seong-Hwa Jeong; Oh-Won Kwon
Journal:  Am J Orthod Dentofacial Orthop       Date:  2006-07       Impact factor: 2.650

3.  Biomechanical optimization of implant diameter and length for immediate loading: a nonlinear finite element analysis.

Authors:  Liang Kong; Zexu Gu; Tao Li; Junjie Wu; Kaijin Hu; Yanpu Liu; Hongzhi Zhou; Baolin Liu
Journal:  Int J Prosthodont       Date:  2009 Nov-Dec       Impact factor: 1.681

4.  Skeletal anchorage system for open-bite correction.

Authors:  M Umemori; J Sugawara; H Mitani; H Nagasaka; H Kawamura
Journal:  Am J Orthod Dentofacial Orthop       Date:  1999-02       Impact factor: 2.650

5.  Effect of placement angle on the stability of loaded titanium microscrews: a microcomputed tomographic and biomechanical analysis.

Authors:  Lixing Zhao; Zhenrui Xu; Xing Wei; Zhihe Zhao; Zhi Yang; Linkun Zhang; Juan Li; Tian Tang
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-05       Impact factor: 2.650

6.  Upper molar intrusion.

Authors:  B Melsen; G Fiorelli
Journal:  J Clin Orthod       Date:  1996-02

7.  Specific mechanics for abutment uprighting.

Authors:  L A Norton; I Lopes
Journal:  Aust Dent J       Date:  1980-10       Impact factor: 2.291

8.  The possibility of skeletal anchorage.

Authors:  T D Creekmore; M K Eklund
Journal:  J Clin Orthod       Date:  1983-04

9.  Maxillary molar intrusion with micro-implant anchorage (MIA).

Authors:  Hyo-Sang Park; Bong-Kyu Jang; Hee-Moon Kyung
Journal:  Aust Orthod J       Date:  2005-11

10.  "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch.

Authors:  Paola Maria Poggio; Cristina Incorvati; Stefano Velo; Aldo Carano
Journal:  Angle Orthod       Date:  2006-03       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.