Investigation of physical image characteristics and phenomenon of edge enhancement by phase contrast using equipment typical for mammography.

Asumi Yamazaki1, Katsuhiro Ichikawa, Yoshie Kodera.   

Abstract

A technique called phase contrast mammography (PCM) has only recently been applied in clinical examination. In this application, PCM images are acquired at a 1.75 x magnification using an x-ray tube for clinical use, and then reduced to the real size of the object by image processing. The images showed enhanced object edges; reportedly, this enhancement occurred because of the refraction of x rays through a cylindrical object. The authors measured the physical image characteristics of PCM to compare the image characteristics of PCM with those of conventional mammography. More specifically, they measured the object-edge-response characteristics and the noise characteristics in the spatial frequency domain. The results revealed that the edge-response characteristics of PCM outperformed those of conventional mammography. In addition, the characteristics changed with the object-placement conditions and the object shapes. The noise characteristics of PCM were better than those of conventional mammography. Subsequently, to verify why object edges were enhanced in PCM images, the authors simulated image profiles that would be obtained if the x rays were refracted and totally reflected by using not only a cylindrical substance but also a planar substance as the object. So, they confirmed that the object edges in PCM images were enhanced because x rays were refracted irrespective of the object shapes. Further, they found that the edge enhancements depended on the object shapes and positions. It was also proposed that the larger magnification than 1.75 in the commercialized system might be more suitable for PCM. Finally, the authors investigated phase-contrast effects to breast tissues by the simulation and demonstrated that PCM would be helpful in the diagnoses of mammography.

Entities:  

Mesh:

Year:  2008        PMID: 19070248     DOI: 10.1118/1.2968091

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Image-quality assessment method for digital phase-contrast imaging based on two-dimensional power spectral analysis.

Authors:  Satoru Matsuo; Junji Morishita; Tetsuro Katafuchi; Chika Honda; Hiroshi Fujita
Journal:  Radiol Phys Technol       Date:  2011-11-10

2.  Innovative radiographic system to improve the sharpness of radiographs: could a phase-shift effect contribute to improved image-quality for plain computed radiographs for general use?

Authors:  Junji Tanaka; Hiromi Oda; Toshihide Mimura; Chika Honda; Hiromu Oohara; Hiroaki Kawasaki; Atsushi Kondo; Yukihito Wada
Journal:  Jpn J Radiol       Date:  2010-01-30       Impact factor: 2.374

3.  Adaptation of a clustered lumpy background model for task-based image quality assessment in x-ray phase-contrast mammography.

Authors:  Adam M Zysk; Jovan G Brankov; Miles N Wernick; Mark A Anastasio
Journal:  Med Phys       Date:  2012-02       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.