Quantification of vessel wall cyclic strain using cine phase contrast magnetic resonance imaging.

Mary T Draney1, Robert J Herfkens, Thomas J R Hughes, Norbert J Pelc, Kristin L Wedding, Christopher K Zarins, Charles A Taylor.   

Abstract

In vivo quantification of vessel wall cyclic strain has important applications in physiology and disease research and the design of intravascular devices. We describe a method to calculate vessel wall strain from cine PC-MRI velocity data. Forward-backward time integration is used to calculate displacement fields from the velocities, and cyclic Green-Lagrange strain is computed in segments defined by the displacements. The method was validated using a combination of in vitro cine PC-MRI and marker tracking studies. Phantom experiments demonstrated that wall displacements and strain could be calculated accurately from PC-MRI velocity data, with a mean displacement difference of 0.20 +/- 0.16 mm (pixel size 0.39 mm) and a mean strain difference of 0.01 (strain extent 0.20). A propagation of error analysis defined the relationship between the standard deviations in displacements and strain based on original segment length and strain magnitude. Based on the measured displacement standard deviation, strain standard deviations were calculated to be 0.015 (validation segment length) and 0.045 (typical segment length). To verify the feasibility of using this method in vivo, cyclic strain was calculated in the thoracic aorta of a normal human subject. Results demonstrated nonuniform deformation and circumferential variation in cyclic strain, with a peak average strain of 0.08 +/- 0.11.

Entities:  

Mesh:

Year:  2002        PMID: 12449764     DOI: 10.1114/1.1513566

Source DB:  PubMed          Journal:  Ann Biomed Eng        ISSN: 0090-6964            Impact factor:   3.934


  15 in total

Review 1.  Importance of hemodynamic forces as signals for exercise-induced changes in endothelial cell phenotype.

Authors:  M Harold Laughlin; Sean C Newcomer; Shawn B Bender
Journal:  J Appl Physiol (1985)       Date:  2007-12-06

Review 2.  Vascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli.

Authors:  Daniel J Green; Maria T E Hopman; Jaume Padilla; M Harold Laughlin; Dick H J Thijssen
Journal:  Physiol Rev       Date:  2017-04       Impact factor: 37.312

3.  In vivo quantification of regional circumferential Green strain in the thoracic and abdominal aorta by 2D spiral cine DENSE MRI.

Authors:  John S Wilson; Xiaodong Zhong; Jackson B Hair; W Robert Taylor; John Oshinski
Journal:  J Biomech Eng       Date:  2018-07-20       Impact factor: 2.097

4.  In vivo quantification of murine aortic cyclic strain, motion, and curvature: implications for abdominal aortic aneurysm growth.

Authors:  Craig J Goergen; Kyla N Barr; Diem T Huynh; Jeffrey R Eastham-Anderson; Gilwoo Choi; Maj Hedehus; Ronald L Dalman; Andrew J Connolly; Charles A Taylor; Philip S Tsao; Joan M Greve
Journal:  J Magn Reson Imaging       Date:  2010-10       Impact factor: 4.813

5.  Plastic strains during stent deployment have a critical influence on the rate of corrosion in absorbable magnesium stents.

Authors:  Emmet Galvin; Christy Cummins; Shoichiro Yoshihara; Bryan J Mac Donald; Caitríona Lally
Journal:  Med Biol Eng Comput       Date:  2016-10-26       Impact factor: 2.602

6.  Measuring aortic pulse wave velocity using high-field cardiovascular magnetic resonance: comparison of techniques.

Authors:  El-Sayed H Ibrahim; Kevin R Johnson; Alan B Miller; Jean M Shaffer; Richard D White
Journal:  J Cardiovasc Magn Reson       Date:  2010-05-11       Impact factor: 5.364

7.  Estimation of nonlinear mechanical properties of vascular tissues via elastography.

Authors:  Reza Karimi; Ting Zhu; Brett E Bouma; Mohammad R Kaazempur Mofrad
Journal:  Cardiovasc Eng       Date:  2008-12

8.  MR elastography of the human abdominal aorta: a preliminary study.

Authors:  Lei Xu; Jun Chen; Kevin J Glaser; Meng Yin; Phillip J Rossman; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2013-01-31       Impact factor: 4.813

9.  Circumferential and longitudinal cyclic strain of the human thoracic aorta: age-related changes.

Authors:  Tina M Morrison; Gilwoo Choi; Christopher K Zarins; Charles A Taylor
Journal:  J Vasc Surg       Date:  2009-04       Impact factor: 4.268

Review 10.  The role of geometric and biomechanical factors in abdominal aortic aneurysm rupture risk assessment.

Authors:  Samarth S Raut; Santanu Chandra; Judy Shum; Ender A Finol
Journal:  Ann Biomed Eng       Date:  2013-03-19       Impact factor: 3.934

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.