Scratches on the metal bearing surface of metal-on-polyethylene total joint replacements have been found to appreciably accelerate abrasive/adhesive wear of polyethylene, and constitute a source of the considerable variability of wear rate seen within clinical cohorts. Scratch orientation with respect to the local direction of relative surface sliding is presumably a factor affecting instantaneous debris liberation during articulation. A three-dimensional local finite element model was developed, of orientation-specific polyethylene articulation with a scratched metal counterface, to explore continuum-level stress/strain parameters potentially correlating with the orientation dependence of scratch wear in a corresponding physical experiment. Computed maximum stress values exceeded the yield strength of ultra-high molecular weight polyethylene (UHMWPE) for all scratch orientations but did not vary appreciably among scratch orientations. Two continuum-level parameters judged most consistent overall with the direction dependence of experimental wear were (1) cumulative compressive total normal strain in the direction of loading, and (2) maximum instantaneous compressive total normal strain transverse to the sliding direction. Such stress/strain metrics could be useful in global computational models of wear acceleration, as surrogates to incorporate anisotropy of local metal surface roughening.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19045548      PMCID: PMC2593842          DOI: 10.1115/1.2939273

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  22 in total

1.  The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement.

Authors:  A P Elfick; R M Hall; I M Pinder; A Unsworth
Journal:  J Biomed Mater Res       Date:  1999

2.  Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.

Authors:  M M Endo; P S Barbour; D C Barton; J Fisher; J L Tipper; E Ingham; M H Stone
Journal:  Biomed Mater Eng       Date:  2001       Impact factor: 1.300

3.  Quantification of third-body damage and its effect on UHMWPE wear with different types of femoral head.

Authors:  H Minakawa; M H Stone; B M Wroblewski; J G Lancaster; E Ingham; J Fisher
Journal:  J Bone Joint Surg Br       Date:  1998-09

4.  Analysis of prosthetic femoral heads retrieved at autopsy.

Authors:  C J Sychterz; C A Engh; S W Swope; D E McNulty; C A Engh
Journal:  Clin Orthop Relat Res       Date:  1999-01       Impact factor: 4.176

5.  The origin of submicron polyethylene wear debris in total hip arthroplasty.

Authors:  H A McKellop; P Campbell; S H Park; T P Schmalzried; P Grigoris; H C Amstutz; A Sarmiento
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

6.  Surface damage to cobalt-chrome femoral head prostheses.

Authors:  M Jasty; C R Bragdon; K Lee; A Hanson; W H Harris
Journal:  J Bone Joint Surg Br       Date:  1994-01

7.  Wear characteristics of UHMW polyethylene: a method for accurately measuring extremely low wear rates.

Authors:  H McKellop; I C Clarke; K L Markolf; H C Amstutz
Journal:  J Biomed Mater Res       Date:  1978-11

8.  The Frank Stinchfield Award. 3-Dimensional sliding/contact computational simulation of total hip wear.

Authors:  T A Maxian; T D Brown; D R Pedersen; J J Callaghan
Journal:  Clin Orthop Relat Res       Date:  1996-12       Impact factor: 4.176

9.  Local head roughening as a factor contributing to variability of total hip wear: a finite element analysis.

Authors:  Thomas D Brown; Kristofer J Stewart; John C Nieman; Douglas R Pedersen; John J Callaghan
Journal:  J Biomech Eng       Date:  2002-12       Impact factor: 2.097

10.  Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.

Authors:  M Mirghany; Z M Jin
Journal:  Proc Inst Mech Eng H       Date:  2004       Impact factor: 1.617

View more
  2 in total

Review 1.  2009 Nicolas Andry Award: clinical biomechanics of third body acceleration of total hip wear.

Authors:  Thomas D Brown; Hannah J Lundberg; Douglas R Pedersen; John J Callaghan
Journal:  Clin Orthop Relat Res       Date:  2009-04-28       Impact factor: 4.176

2.  A novel formulation for scratch-based wear modelling in total hip arthroplasty.

Authors:  Karen M Kruger; Nishant M Tikekar; Anneliese D Heiner; Thomas E Baer; John J Lannutti; John J Callaghan; Thomas D Brown
Journal:  Comput Methods Biomech Biomed Engin       Date:  2013-01-10       Impact factor: 1.763

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.