Literature DB >> 11281576

Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene.

M M Endo1, P S Barbour, D C Barton, J Fisher, J L Tipper, E Ingham, M H Stone.   

Abstract

The wear debris generated from ultra high molecular weight polyethylene (UHMWPE) have been recognised as one of the major causes of failure in total hip replacements (THR). It is essential to reduce the wear debris generated from UHMWPE acetabular cups in order to minimise this problem. Debris in the submicron size range is believed to have greater osteolytic potential. It is now known that crosslinked UHMWPE acetabular cups have reduced volumetric wear rates but little is known about the influence of crosslinking on the size and morphology of the wear debris. In this study, the wear of grade GUR 1020 crosslinked (vacuum gamma irradiated), GUR 1120 crosslinked (acetylene enhanced irradiated) and non cross linked (ethylene oxide sterilised) GUR 1020 UHMWPE was compared in multidirectional pin-on-plate wear tests under three different counterface conditions (smooth, isotropically rough and scratched counterfaces). Multidirectional motion was chosen because this motion was closer to the relative motion in the natural hip. From this study, better wear resistance of crosslinked UHMWPE compared with non-crosslinked UHMWPE was demonstrated for the smooth counterface conditions. However, in the rough and scratched counterface conditions, the vacuum gamma irradiated crosslinked material produced significantly higher wear rates than the non-crosslinked material. The analysis of the wear debris showed that the majority of the volume of the acetylene enhanced crosslinked UHMWPE wear debris was in the most biologically active size range (0.1 to 0.5 microm). In contrast, the non-crosslinked material and the vacuum gamma irradiated crosslinked material had a greater proportion of the volume of the debris in the larger size ranges which are less biologically active. This has important implications for its osteolytic potential.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11281576

Source DB:  PubMed          Journal:  Biomed Mater Eng        ISSN: 0959-2989            Impact factor:   1.300


  11 in total

1.  The John Charnley Award: an accurate and sensitive method to separate, display, and characterize wear debris: part 1: polyethylene particles.

Authors:  Fabrizio Billi; Paul Benya; Aaron Kavanaugh; John Adams; Edward Ebramzadeh; Harry McKellop
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Wear of crosslinked polyethylene under different tribological conditions.

Authors:  Alison Galvin; Lu Kang; Joanne Tipper; Martin Stone; Eileen Ingham; Zhongmin Jin; John Fisher
Journal:  J Mater Sci Mater Med       Date:  2006-03       Impact factor: 3.896

3.  Field variable associations with scratch orientation dependence of UHMWPE wear: a finite element analysis.

Authors:  Matthew C Paul; Liam P Glennon; Thomas E Baer; Thomas D Brown
Journal:  J Biomech Eng       Date:  2008-12       Impact factor: 2.097

4.  Effects of episodic subluxation events on third body ingress and embedment in the THA bearing surface.

Authors:  Anneliese D Heiner; Hannah J Lundberg; Thomas E Baer; Douglas R Pedersen; John J Callaghan; Thomas D Brown
Journal:  J Biomech       Date:  2008-06-17       Impact factor: 2.712

5.  Characteristics of highly cross-linked polyethylene wear debris in vivo.

Authors:  Ryan M Baxter; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

6.  The John Charnley Award: Highly crosslinked polyethylene in total hip arthroplasty decreases long-term wear: a double-blind randomized trial.

Authors:  Siôn Glyn-Jones; Geraint E R Thomas; Patrick Garfjeld-Roberts; Roger Gundle; Adrian Taylor; Peter McLardy-Smith; David W Murray
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

7.  Scratching vulnerability of conventional vs highly cross-linked polyethylene liners because of large embedded third-body particles.

Authors:  Anneliese D Heiner; Alison L Galvin; John Fisher; John J Callaghan; Thomas D Brown
Journal:  J Arthroplasty       Date:  2011-11-23       Impact factor: 4.757

8.  Sliding direction dependence of polyethylene wear for metal counterface traverse of severe scratches.

Authors:  Liam P Glennon; Thomas E Baer; James A Martin; William D Lack; Thomas D Brown
Journal:  J Biomech Eng       Date:  2008-10       Impact factor: 2.097

Review 9.  How has the introduction of new bearing surfaces altered the biological reactions to byproducts of wear and modularity?

Authors:  Paul H Wooley
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

10.  Analysis of wear, wear particles, and reduced inflammatory potential of vitamin E ultrahigh-molecular-weight polyethylene for use in total joint replacement.

Authors:  C L Bladen; S Teramura; S L Russell; K Fujiwara; J Fisher; E Ingham; N Tomita; J L Tipper
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.