Literature DB >> 10490687

The influence of femoral head surface roughness on the wear of ultrahigh molecular weight polyethylene sockets in cementless total hip replacement.

A P Elfick1, R M Hall, I M Pinder, A Unsworth.   

Abstract

A theoretical relationship was recently proposed relating the wear behavior of polymetric bearing materials articulating against hard counterfaces.(1) This model attempts to predict the influence of surface roughness on wear. Laboratory-based studies have been used to establish the validity of these relationships, but their application to the clinical situation has not been investigated fully. Forty-two retrieved PCA hip joints have been assessed. The total wear volume was calculated from the penetration measured using the shadowgraph method, and roughness of the articulating surfaces was recorded using noncontacting profilometry. The roughness of the explanted femoral heads was observed to increase (median S(a) - 10. 35 nm worn region, 3.05 nm peripheral region), while that of the acetabular liner fell dramatically (median S(a) - 41 nm worn region, 212 nm unworn region). No evidence of a relationship between the topography of the worn regions of the femoral head and that of the acetabular liner could be found. Similarly, the strength of the association between the surface roughness and the clinical wear factor was considerably poorer than that achieved in laboratory experiments. A number of reasons for this observation are proposed. Most deleterious was considered to be the inability of the roughness parameters to describe the damaging features of the surface adequately. Uncertainty as to when the surface of the component degrades during its life serves to introduce further doubt as to the application of the wear models in the clinical environment. In conclusion, this study fails to provide clinical evidence to substantiate the relationship between surface finish and wear rate. The adoption of standardized measurement parameters and techniques would facilitate the direct comparison of joint types and the selection of the most advantageous materials. Copyright 1999 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10490687     DOI: 10.1002/(sici)1097-4636(1999)48:5<712::aid-jbm17>3.0.co;2-r

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  4 in total

1.  Field variable associations with scratch orientation dependence of UHMWPE wear: a finite element analysis.

Authors:  Matthew C Paul; Liam P Glennon; Thomas E Baer; Thomas D Brown
Journal:  J Biomech Eng       Date:  2008-12       Impact factor: 2.097

2.  Wear testing of a DJOA finger prosthesis in vitro.

Authors:  Thomas J Joyce
Journal:  J Mater Sci Mater Med       Date:  2010-02-11       Impact factor: 3.896

3.  How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  J Mater Sci Mater Med       Date:  2014-07-12       Impact factor: 3.896

4.  Manufacturing conditioned roughness and wear of biomedical oxide ceramics for all-ceramic knee implants.

Authors:  Anke Turger; Jens Köhler; Berend Denkena; Tomas A Correa; Christoph Becher; Christof Hurschler
Journal:  Biomed Eng Online       Date:  2013-08-29       Impact factor: 2.819

  4 in total