Literature DB >> 26390678

Performance and Safety of an Integrated Portable Extracorporeal Life Support System for Adults.

Cory M Alwardt, Donald S Wilson, Michelle L Alore, Louis A Lanza, Patrick A Devaleria, Octavio E Pajaro.   

Abstract

Extracorporeal membrane oxygenation (ECMO) is indicated when conventional measures fail to support a patient during cardiac or respiratory failure. Due to the complicated nature of ECMO, patients often require transport to a tertiary care center. This study retrospectively compared the performance of the Cardiohelp™ (Maquet) life support system with a previously used ECMO circuit when transporting adult patients on venoarterial ECMO between facilities. Two ECMO circuits were compared for performance: 1) the Cardiohelp™ (Maquet) life support system and 2) the "standard" circuit consisting of a Thoratec CentriMag centrifugal pump, Maquet Quadrox-D oxygenator, and a Terumo CDI-500 in-line blood gas analyzer. After analyzing data from 16 patients (eight patients supported with each ECMO system), no differences in patient demographics, percentage of patients successfully weaned from ECMO, percentage of patients surviving to discharge, duration supported on the initial ECMO system, or total duration of ECMO were noted. No patient deaths were related to circuit failure or circuit disruptions in either group. Analysis of the performance of the ECMO circuits and the resulting patient status showed few significant differences between ECMO groups (Cardiohelp™ vs. standard circuit) and time points (the first 8 hours vs. a 24-hour time point). The statistically significant differences were not concerning in terms of appropriate medical support or patient safety. Of interest, the transmembrane pressure was significantly lower for the Cardiohelp™ module vs. the standard oxygenator during the first 8 hours (20.1 [5.3] vs. 37.1 [7.1] mmHg; p < .001) and at 24 hours (21.3 [3.8] vs. 34.8 [7.9] mmHg; p = .001). The Cardiohelp™ portable life support system provides safe and reliable support for adult patients on ECMO during interhospital patient transport as compared to the standard circuit.

Entities:  

Mesh:

Year:  2015        PMID: 26390678      PMCID: PMC4566819     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  13 in total

1.  Portable miniaturized extracorporeal membrane oxygenation systems for H1N1-related severe acute respiratory distress syndrome: a case series.

Authors:  Roberto Roncon-Albuquerque; Carla Basílio; Paulo Figueiredo; Sofia Silva; Paulo Mergulhão; Carlos Alves; Rui Veiga; Salomé Castelo-Branco; Lúcia Paiva; Lurdes Santos; Teresa Honrado; Celeste Dias; Teresa Oliveira; António Sarmento; Ana Maria Mota; José Artur Paiva
Journal:  J Crit Care       Date:  2012-03-03       Impact factor: 3.425

2.  First experience with the new portable extracorporeal membrane oxygenation system Cardiohelp for severe respiratory failure in adults.

Authors:  A Haneya; A Philipp; M Foltan; D Camboni; T Müeller; T Bein; C Schmid; M Lubnow
Journal:  Perfusion       Date:  2012-01-16       Impact factor: 1.972

3.  A traveling team concept to expedite the transfer and management of unstable patients in cardiopulmonary shock.

Authors:  Dawn E Jaroszewski; Thomas Kleisli; Linda Staley; Christopher Pierce; Robert Scott; David Eric Steidley; Patrick DeValeria; Francisco A Arabia
Journal:  J Heart Lung Transplant       Date:  2011-01-15       Impact factor: 10.247

4.  Pressure drop, shear stress, and activation of leukocytes during cardiopulmonary bypass: a comparison between hollow fiber and flat sheet membrane oxygenators.

Authors:  Y J Gu; P W Boonstra; R Graaff; A A Rijnsburger; H Mungroop; W van Oeveren
Journal:  Artif Organs       Date:  2000-01       Impact factor: 3.094

5.  Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model.

Authors:  J Dubois; L Jamaer; U Mees; J- L Pauwels; F Briers; J Lehaen; M Hendrikx
Journal:  Perfusion       Date:  2004       Impact factor: 1.972

6.  First experience with the ultra compact mobile extracorporeal membrane oxygenation system Cardiohelp in interhospital transport.

Authors:  Alois Philipp; Matthias Arlt; Matthias Amann; Dirk Lunz; Thomas Müller; Michael Hilker; Bernhard Graf; Christof Schmid
Journal:  Interact Cardiovasc Thorac Surg       Date:  2011-03-08

7.  Efficiency in extracorporeal membrane oxygenation-cellular deposits on polymethylpentene membranes increase resistance to blood flow and reduce gas exchange capacity.

Authors:  Karla Lehle; Alois Philipp; Otto Gleich; Andreas Holzamer; Thomas Müller; Thomas Bein; Christof Schmid
Journal:  ASAIO J       Date:  2008 Nov-Dec       Impact factor: 2.872

8.  Extracorporeal Life Support Organization Registry Report 2012.

Authors:  Matthew L Paden; Steven A Conrad; Peter T Rycus; Ravi R Thiagarajan
Journal:  ASAIO J       Date:  2013 May-Jun       Impact factor: 2.872

9.  Regional perfusion during venoarterial extracorporeal membrane oxygenation: a case report and educational modules on the concept of dual circulations.

Authors:  Cory M Alwardt; Bhavesh M Patel; Amelia Lowell; Jeff Dobberpuhl; Jeffrey B Riley; Patrick A DeValeria
Journal:  J Extra Corpor Technol       Date:  2013-09

10.  Bridge to decision: SWAT team approach used by Mayo Clinic Arizona's cardiac transport team.

Authors:  Linda L Staley; Jeff Dobberpuhl; Christopher N Pierce; Robert L Scott; Dawn E Jaroszewski; Francisco A Arabia
Journal:  Prog Transplant       Date:  2010-06       Impact factor: 1.065

View more
  5 in total

1.  Iatrogenic Extracorporeal Membrane Oxygenator Rupture: Successful Management of a Unique Crisis.

Authors:  Kaushalendra Rathore; Garry Smith; Mark Newman
Journal:  J Extra Corpor Technol       Date:  2020-09

Review 2.  Remote cannulation and extracorporeal membrane oxygenation transport is safe in a newly established program.

Authors:  David S Grenda; Vanessa Moll; Craig M Kalin; James M Blum
Journal:  Ann Transl Med       Date:  2017-02

Review 3.  Development of a new interfacility extracorporeal membrane oxygenation transport program for pediatric lung transplantation evaluation.

Authors:  W Joshua Frazier; Edward G Shepherd; Samantha W Gee
Journal:  Ann Transl Med       Date:  2017-02

Review 4.  Real-Time Monitoring of Blood Parameters in the Intensive Care Unit: State-of-the-Art and Perspectives.

Authors:  Rebecca Bockholt; Shaleen Paschke; Lars Heubner; Bergoi Ibarlucea; Alexander Laupp; Željko Janićijević; Stephanie Klinghammer; Sascha Balakin; Manfred F Maitz; Carsten Werner; Gianaurelio Cuniberti; Larysa Baraban; Peter Markus Spieth
Journal:  J Clin Med       Date:  2022-04-25       Impact factor: 4.964

5.  Computational fluid dynamics analysis and experimental hemolytic performance of three clinical centrifugal blood pumps: Revolution, Rotaflow and CentriMag.

Authors:  Dong Han; Joshua L Leibowitz; Lu Han; Shigang Wang; Ge He; Bartley P Griffith; Zhongjun J Wu
Journal:  Med Nov Technol Devices       Date:  2022-06-19
  5 in total