Literature DB >> 19030855

Image-derived input functions for PET brain studies.

Jurgen E M Mourik1, Mark Lubberink, Alie Schuitemaker, Nelleke Tolboom, Bart N M van Berckel, Adriaan A Lammertsma, Ronald Boellaard.   

Abstract

PURPOSE: To assess the robustness of a previously introduced method to obtain accurate image-derived input functions (IDIF) for three other tracers.
METHODS: Dynamic PET and online blood data of five repeat [(11)C]PIB (Pittsburgh Compound-B) ([(11)C]PIB), six repeat (R)-[(11)C]verapamil, and ten single (R)-[(11)C]PK11195 studies were used. IDIFs were extracted from partial volume corrected scans using the four hottest pixels per plane method. Results obtained with IDIFs were compared with those using standard online measured arterial input functions (BSIF). IDIFs were used both with and without calibration based on manual blood samples.
RESULTS: For (R)-[(11)C]verapamil, accurate IDIFs were obtained using noncalibrated IDIFs (slope 0.96+/-0.17; R (2) 0.92+/-0.07). However, calibration was necessary to obtain IDIFs comparable to the BSIF for both [(11)C]PIB (slope 1.04+/-0.05; R (2) 1.00+/-0.01) and (R)-[(11)C]PK11195 (slope 0.96+/-0.05; R (2) 0.99+/-0.01). The need for calibration may be explained by the sticking property of both tracers, indicating that BSIF may be affected by sticking and therefore may be unreliable.
CONCLUSION: The present study shows that a previously proposed method to extract IDIFs is suitable for analysing [(11)C]PIB, (R)-[(11)C]verapamil and (R)-[(11)C]PK11195 studies, thereby obviating the need for online arterial sampling.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19030855     DOI: 10.1007/s00259-008-0986-8

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  19 in total

1.  Characteristics of a new fully programmable blood sampling device for monitoring blood radioactivity during PET.

Authors:  R Boellaard; A van Lingen; S C van Balen; B G Hoving; A A Lammertsma
Journal:  Eur J Nucl Med       Date:  2001-01

2.  Graphical analysis of PET data applied to reversible and irreversible tracers.

Authors:  J Logan
Journal:  Nucl Med Biol       Date:  2000-10       Impact factor: 2.408

3.  Evaluation of tracer kinetic models for quantification of P-glycoprotein function using (R)-[11C]verapamil and PET.

Authors:  Mark Lubberink; Gert Luurtsema; Bart N M van Berckel; Ronald Boellaard; Rolf Toornvliet; Albert D Windhorst; Eric J F Franssen; Adriaan A Lammertsma
Journal:  J Cereb Blood Flow Metab       Date:  2006-06-07       Impact factor: 6.200

4.  Evaluation of methods for generating parametric (R-[11C]PK11195 binding images.

Authors:  Alie Schuitemaker; Bart N M van Berckel; Marc A Kropholler; Reina W Kloet; Cees Jonker; Philip Scheltens; Adriaan A Lammertsma; Ronald Boellaard
Journal:  J Cereb Blood Flow Metab       Date:  2007-02-21       Impact factor: 6.200

5.  Partial volume corrected image derived input functions for dynamic PET brain studies: methodology and validation for [11C]flumazenil.

Authors:  Jurgen E M Mourik; Mark Lubberink; Ursula M H Klumpers; Emile F Comans; Adriaan A Lammertsma; Ronald Boellaard
Journal:  Neuroimage       Date:  2007-11-28       Impact factor: 6.556

6.  Simplified reference tissue model for PET receptor studies.

Authors:  A A Lammertsma; S P Hume
Journal:  Neuroimage       Date:  1996-12       Impact factor: 6.556

7.  Simultaneous correction for tracer arrival delay and dispersion in CBF measurements by the H215O autoradiographic method and dynamic PET.

Authors:  E Meyer
Journal:  J Nucl Med       Date:  1989-06       Impact factor: 10.057

8.  Pulseless arm after brachial-artery catheterisation.

Authors:  H I Machleder; J P Sweeney; W F Barker
Journal:  Lancet       Date:  1972-02-19       Impact factor: 79.321

9.  Comparison of methods for analysis of clinical [11C]raclopride studies.

Authors:  A A Lammertsma; C J Bench; S P Hume; S Osman; K Gunn; D J Brooks; R S Frackowiak
Journal:  J Cereb Blood Flow Metab       Date:  1996-01       Impact factor: 6.200

10.  Deposition of Alzheimer's beta-amyloid is inversely correlated with P-glycoprotein expression in the brains of elderly non-demented humans.

Authors:  Silke Vogelgesang; Ingolf Cascorbi; Eike Schroeder; Jens Pahnke; Heyo K Kroemer; Werner Siegmund; Christiane Kunert-Keil; Lary C Walker; Rolf W Warzok
Journal:  Pharmacogenetics       Date:  2002-10
View more
  23 in total

1.  Minimally invasive input function for 2-18F-fluoro-A-85380 brain PET studies.

Authors:  Paolo Zanotti-Fregonara; Renaud Maroy; Marie-Anne Peyronneau; Régine Trebossen; Michel Bottlaender
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-01-10       Impact factor: 9.236

Review 2.  Amyloid imaging with PET: methodological issues and correlative studies.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-06       Impact factor: 9.236

Review 3.  Image-derived input function for brain PET studies: many challenges and few opportunities.

Authors:  Paolo Zanotti-Fregonara; Kewei Chen; Jeih-San Liow; Masahiro Fujita; Robert B Innis
Journal:  J Cereb Blood Flow Metab       Date:  2011-08-03       Impact factor: 6.200

4.  Image-derived input function in dynamic human PET/CT: methodology and validation with 11C-acetate and 18F-fluorothioheptadecanoic acid in muscle and 18F-fluorodeoxyglucose in brain.

Authors:  Etienne Croteau; Eric Lavallée; Sébastien M Labbe; Laurent Hubert; Fabien Pifferi; Jacques A Rousseau; Stephen C Cunnane; André C Carpentier; Roger Lecomte; François Bénard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-05-02       Impact factor: 9.236

Review 5.  PET amyloid-beta imaging in preclinical Alzheimer's disease.

Authors:  Andrei G Vlassenko; Tammie L S Benzinger; John C Morris
Journal:  Biochim Biophys Acta       Date:  2011-11-12

6.  Image-derived input function in PET brain studies: blood-based methods are resistant to motion artifacts.

Authors:  Paolo Zanotti-Fregonara; Jeih-San Liow; Claude Comtat; Sami S Zoghbi; Yi Zhang; Victor W Pike; Masahiro Fujita; Robert B Innis
Journal:  Nucl Med Commun       Date:  2012-09       Impact factor: 1.690

7.  Compensation for spill-in and spill-out partial volume effects in cardiac PET imaging.

Authors:  Yong Du; Igal Madar; Martin J Stumpf; Xing Rong; George S K Fung; Eric C Frey
Journal:  J Nucl Cardiol       Date:  2012-11-14       Impact factor: 5.952

8.  In vivo validation of reconstruction-based resolution recovery for human brain studies.

Authors:  Jurgen E M Mourik; Mark Lubberink; Floris H P van Velden; Reina W Kloet; Bart N M van Berckel; Adriaan A Lammertsma; Ronald Boellaard
Journal:  J Cereb Blood Flow Metab       Date:  2009-10-21       Impact factor: 6.200

9.  Off-line motion correction methods for multi-frame PET data.

Authors:  Jurgen E M Mourik; Mark Lubberink; Floris H P van Velden; Adriaan A Lammertsma; Ronald Boellaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-12       Impact factor: 9.236

10.  Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney.

Authors:  Tao Feng; Benjamin M W Tsui; Xin Li; Melin Vranesic; Martin A Lodge; Nedim C M Gulaldi; Zsolt Szabo
Journal:  Med Phys       Date:  2015-11       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.