Literature DB >> 19028742

Wide-field digital retinal imaging versus binocular indirect ophthalmoscopy for retinopathy of prematurity screening: a two-observer prospective, randomised comparison.

C Dhaliwal1, E Wright, C Graham, N McIntosh, B W Fleck.   

Abstract

AIM: To compare the diagnostic accuracy of wide-field digital retinal imaging (WFDRI) with the current "gold standard" of binocular indirect ophthalmoscopy (BIO) for retinopathy of prematurity (ROP) screening examinations.
METHODS: A consecutive series of premature infants undergoing ROP screening at Edinburgh Royal Infirmary were eligible for recruitment into this prospective, randomised, comparative study. Infants were screened using both WFDRI (Retcam II with neonatal lens) and BIO by two paediatric ophthalmologists who were randomised to the examination technique. Both examiners documented their clinical findings and management plans in a masked fashion. WFDRI eye findings were compared with those of BIO.
RESULTS: A total of 81 infants were recruited, and information from 245 eye examinations was analysed. The sensitivity of WFDRI in detecting any stage of ROP, stage 3 ROP and "plus" disease was 60%, 57% and 80%, respectively, and specificity 91%, 98% and 98%, respectively. The proportional agreement between WFDRI and BIO was 0.96 for detecting stage 3 disease and 0.97 for detecting "plus" disease. There was very good agreement on management decisions (kappa 0.85).
CONCLUSION: When used in a routine ROP screening setting, a randomised comparison of WFDRI and BIO, WFDRI showed relatively poor sensitivity in detecting mild forms of ROP in the retinal periphery. This resulted in difficulty in making decisions to discharge infants from the screening programme. Sensitivity was better for more severe forms of ROP, but at present WFDRI should be regarded as an adjunct to, rather than a replacement for, BIO in routine ROP screening.

Entities:  

Mesh:

Year:  2008        PMID: 19028742     DOI: 10.1136/bjo.2008.148908

Source DB:  PubMed          Journal:  Br J Ophthalmol        ISSN: 0007-1161            Impact factor:   4.638


  21 in total

1.  Detection of clinically significant retinopathy of prematurity using wide-angle digital retinal photography: a report by the American Academy of Ophthalmology.

Authors:  Michael F Chiang; Michele Melia; Angela N Buffenn; Scott R Lambert; Franco M Recchia; Jennifer L Simpson; Michael B Yang
Journal:  Ophthalmology       Date:  2012-04-27       Impact factor: 12.079

2.  Where is the junction of zone 2 and zone 3 temporal retina in RetCam images of acute retinopathy of prematurity?

Authors:  B W Fleck
Journal:  Eye (Lond)       Date:  2015-03-27       Impact factor: 3.775

Review 3.  Adenosine receptors and caffeine in retinopathy of prematurity.

Authors:  Jiang-Fan Chen; Shuya Zhang; Rong Zhou; Zhenlang Lin; Xiaohong Cai; Jing Lin; Yuqing Huo; Xiaoling Liu
Journal:  Mol Aspects Med       Date:  2017-01-11

4.  Alternative methods for the screening of retinopathy of prematurity: binocular indirect ophthalmoscopy vs wide-field digital retinal imaging.

Authors:  M A Sekeroglu; E Hekimoglu; H T Sekeroglu; U Arslan
Journal:  Eye (Lond)       Date:  2013-06-14       Impact factor: 3.775

5.  Telemedicine approaches to evaluating acute-phase retinopathy of prematurity: study design.

Authors: 
Journal:  Ophthalmic Epidemiol       Date:  2014-06-23       Impact factor: 1.648

Review 6.  A comprehensive review of diagnostic imaging technologies to evaluate the retina and the optic disk.

Authors:  Asima Bajwa; Rabia Aman; Ashvini K Reddy
Journal:  Int Ophthalmol       Date:  2015-06-05       Impact factor: 2.031

7.  Caffeine preferentially protects against oxygen-induced retinopathy.

Authors:  Shuya Zhang; Rong Zhou; Bo Li; Haiyan Li; Yanyan Wang; Xuejiao Gu; Lingyun Tang; Cun Wang; Dingjuan Zhong; Yuanyuan Ge; Yuqing Huo; Jing Lin; Xiao-Ling Liu; Jiang-Fan Chen
Journal:  FASEB J       Date:  2017-04-18       Impact factor: 5.191

8.  Risk Score for Predicting Treatment-Requiring Retinopathy of Prematurity (ROP) in the Telemedicine Approaches to Evaluating Acute-Phase ROP Study.

Authors:  Gui-Shuang Ying; Deborah VanderVeen; Ebenezer Daniel; Graham E Quinn; Agnieshka Baumritter
Journal:  Ophthalmology       Date:  2016-08-02       Impact factor: 12.079

9.  Impact of number and quality of retinal images in a telemedicine screening program for ROP: results from the e-ROP study.

Authors:  David Morrison; Erick D Bothun; Gui-Shuang Ying; Ebenezer Daniel; Agnieshka Baumritter; Graham Quinn
Journal:  J AAPOS       Date:  2016-10-01       Impact factor: 1.220

10.  Trans-pars-planar illumination enables a 200° ultra-wide field pediatric fundus camera for easy examination of the retina.

Authors:  Devrim Toslak; Felix Chau; Muhammet Kazim Erol; Changgeng Liu; R V Paul Chan; Taeyoon Son; Xincheng Yao
Journal:  Biomed Opt Express       Date:  2019-12-05       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.