Literature DB >> 32010500

Trans-pars-planar illumination enables a 200° ultra-wide field pediatric fundus camera for easy examination of the retina.

Devrim Toslak1,2, Felix Chau3, Muhammet Kazim Erol2, Changgeng Liu1, R V Paul Chan3, Taeyoon Son1,4, Xincheng Yao1,3.   

Abstract

This study is to test the feasibility of using trans-pars-planar illumination for ultra-wide field pediatric fundus photography. Fundus examination of the peripheral retina is essential for clinical management of pediatric eye diseases. However, current pediatric fundus cameras with traditional trans-pupillary illumination provide a limited field of view (FOV), making it difficult to access the peripheral retina adequately for a comprehensive assessment of eye conditions. Here, we report the first demonstration of trans-pars-planar illumination in ultra-wide field pediatric fundus photography. For proof-of-concept validation, all off-the-shelf optical components were selected to construct a lab prototype pediatric camera (PedCam). By freeing the entire pupil for imaging purpose only, the trans-pars-planar illumination enables a 200° FOV PedCam, allowing easy visualization of both the central and peripheral retina up to the ora serrata. A low-cost, easy-to-use ultra-wide field PedCam provides a unique opportunity to foster affordable telemedicine in rural and underserved areas.
© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Entities:  

Year:  2019        PMID: 32010500      PMCID: PMC6968751          DOI: 10.1364/BOE.11.000068

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  32 in total

1.  Optimal parameters for retinal illumination and imaging in fundus cameras.

Authors:  E DeHoog; J Schwiegerling
Journal:  Appl Opt       Date:  2008-12-20       Impact factor: 1.980

2.  Optical properties of human sclera, and their consequences for transscleral laser applications.

Authors:  A Vogel; C Dlugos; R Nuffer; R Birngruber
Journal:  Lasers Surg Med       Date:  1991       Impact factor: 4.025

3.  Comparative study of RetCamRetCam II vs. binocular ophthalmoscopy in a screening program for retinopathy of prematurity.

Authors:  P Tejada-Palacios; L Zarratea; M Moral; J de la Cruz-Bértolo
Journal:  Arch Soc Esp Oftalmol       Date:  2015-03-25

4.  Non-contact ultra-widefield imaging of retinopathy of prematurity using the Optos dual wavelength scanning laser ophthalmoscope.

Authors:  C K Patel; T H M Fung; M M K Muqit; D J Mordant; J Brett; L Smith; E Adams
Journal:  Eye (Lond)       Date:  2013-03-22       Impact factor: 3.775

5.  The ora serrata in the adult human eye.

Authors:  B R Straatsma; M B Landers; A E Kreiger
Journal:  Arch Ophthalmol       Date:  1968-07

6.  Optimizing hand-held spectral domain optical coherence tomography imaging for neonates, infants, and children.

Authors:  Ramiro S Maldonado; Joseph A Izatt; Neeru Sarin; David K Wallace; Sharon Freedman; C Michael Cotten; Cynthia A Toth
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-01-13       Impact factor: 4.799

Review 7.  Evaluation of Visunex Medical's PanoCam(TM) LT and PanoCam(TM) Pro wide-field imaging systems for the screening of ROP in newborn infants.

Authors:  Edward H Wood; Andrew A Moshfeghi; Eric D Nudleman; Darius M Moshfeghi
Journal:  Expert Rev Med Devices       Date:  2016-08       Impact factor: 3.166

Review 8.  Retinopathy of prematurity: the need for prevention.

Authors:  Raffael Liegl; Ann Hellström; Lois Eh Smith
Journal:  Eye Brain       Date:  2016-05-20

9.  Findings of perinatal ocular examination performed on 3573, healthy full-term newborns.

Authors:  Li-Hong Li; Na Li; Jun-Yang Zhao; Ping Fei; Guo-ming Zhang; Jian-bo Mao; Paul J Rychwalski
Journal:  Br J Ophthalmol       Date:  2013-02-20       Impact factor: 4.638

Review 10.  Preterm-associated visual impairment and estimates of retinopathy of prematurity at regional and global levels for 2010.

Authors:  Hannah Blencowe; Joy E Lawn; Thomas Vazquez; Alistair Fielder; Clare Gilbert
Journal:  Pediatr Res       Date:  2013-12       Impact factor: 3.756

View more
  5 in total

1.  Portable ultra-widefield fundus camera for multispectral imaging of the retina and choroid.

Authors:  Devrim Toslak; Taeyoon Son; Muhammet Kazim Erol; Hoonsup Kim; Tae-Hoon Kim; R V Paul Chan; Xincheng Yao
Journal:  Biomed Opt Express       Date:  2020-10-12       Impact factor: 3.732

2.  Developing portable widefield fundus camera for teleophthalmology: Technical challenges and potential solutions.

Authors:  Xincheng Yao; Taeyoon Son; Jiechao Ma
Journal:  Exp Biol Med (Maywood)       Date:  2021-12-08

3.  Measuring ocular torsion and its variations using different nonmydriatic fundus photographic methods.

Authors:  Hyunkyoo Kang; Sang Jae Lee; Hyun Jin Shin; Andrew G Lee
Journal:  PLoS One       Date:  2020-12-22       Impact factor: 3.240

4.  Light color efficiency-balanced trans-palpebral illumination for widefield fundus photography of the retina and choroid.

Authors:  Taeyoon Son; Jiechao Ma; Devrim Toslak; Alfa Rossi; Hoonsup Kim; R V Paul Chan; Xincheng Yao
Journal:  Sci Rep       Date:  2022-08-16       Impact factor: 4.996

5.  Impact of illumination spectrum and eye pigmentation on image quality from a fundus camera using transscleral illumination.

Authors:  Alexey Stepanov; Jostein Thorstensen; Jon Tschudi
Journal:  J Biomed Opt       Date:  2021-07       Impact factor: 3.170

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.