Literature DB >> 19025948

Simulation study of susceptibility gradients leading to focal myocardial signal loss.

Douglas J Anderson1, Jeffrey M Dendy, Cynthia B Paschal.   

Abstract

PURPOSE: To assess the cause of a "bite"-shaped signal void artifact often seen in 1.5 Tesla (T) and 3T gradient echo MR images in myocardium along the infero-apical border of the heart, MRI simulation was used to conduct experiments impossible in reality. Two previous studies attempting to explain the origin of this artifact came to different conclusions. One suggested deoxygenated blood in the posterior vein of the left ventricle (PVLV) leads to a susceptibility gradient that causes the artifact. The other suggested the difference in susceptibility between lung tissue and myocardium was responsible. This study assessed the relative effect of each possible cause.
MATERIALS AND METHODS: Anthropometric phantoms were developed for use with a previously reported MRI simulator. The images were simulated at 3T with gradient echo scans using TE = 4 ms, TR = 25 ms, and theta = 25 degrees .
RESULTS: The simulations indicate that both susceptibility differences can lead to signal losses in the area of the artifact with contributions from the PVLV being more localized while lung tissue effects are stronger but more spatially distributed.
CONCLUSION: The data support the conclusion that both differences together, rather than one or the other, are responsible for the artifact. (c) 2008 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2008        PMID: 19025948      PMCID: PMC2987697          DOI: 10.1002/jmri.21619

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  30 in total

1.  T2* and proton density measurement of normal human lung parenchyma using submillisecond echo time gradient echo magnetic resonance imaging.

Authors:  H Hatabu; D C Alsop; J Listerud; M Bonnet; W B Gefter
Journal:  Eur J Radiol       Date:  1999-03       Impact factor: 3.528

Review 2.  Cardiac magnetic resonance imaging.

Authors:  G J Heatlie; K Pointon
Journal:  Postgrad Med J       Date:  2004-01       Impact factor: 2.401

3.  Real-time cardiac MRI at 3 tesla.

Authors:  Krishna S Nayak; Charles H Cunningham; Juan M Santos; John M Pauly
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

4.  MRI simulator with object-specific field map calculations.

Authors:  Duane A Yoder; Yansong Zhao; Cynthia B Paschal; J Michael Fitzpatrick
Journal:  Magn Reson Imaging       Date:  2004-04       Impact factor: 2.546

5.  Quantitation of lung sealing in the survival swine model.

Authors:  Michael V Tirabassi; Gregory T Banever; David B Tashjian; Kevin P Moriarty
Journal:  J Pediatr Surg       Date:  2004-03       Impact factor: 2.545

Review 6.  Assessment of cardiac function by CMR.

Authors:  Guillem Pons-Lladó
Journal:  Eur Radiol       Date:  2005-02       Impact factor: 5.315

7.  Respiratory reordered UNFOLD perfusion imaging.

Authors:  Nicholas A Ablitt; Peter D Gatehouse; David N Firmin; Guang-Zhong Yang
Journal:  J Magn Reson Imaging       Date:  2004-11       Impact factor: 4.813

8.  MR susceptibility misregistration correction.

Authors:  T S Sumanaweera; G H Glover; T O Binford; J R Adler
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

9.  A technique for accurate magnetic resonance imaging in the presence of field inhomogeneities.

Authors:  H Chang; J M Fitzpatrick
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

10.  Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements.

Authors:  C M Wacker; M Bock; A W Hartlep; G Beck; G van Kaick; G Ertl; W R Bauer; L R Schad
Journal:  Magn Reson Med       Date:  1999-04       Impact factor: 4.668

View more
  3 in total

1.  Myocardial Tissue Oxygenation and Microvascular Blood Volume Measurement Using a Contrast Blood Oxygenation Level-Dependent Imaging Model.

Authors:  Jeffrey M Dendy; Sean G Hughes; Jonathan H Soslow; Daniel E Clark; Cynthia B Paschal; John C Gore
Journal:  Invest Radiol       Date:  2022-04-13       Impact factor: 10.065

2.  Improved in vivo measurement of myocardial transverse relaxation with 3 Tesla magnetic resonance imaging.

Authors:  Jared Guthrie Cobb; Cynthia B Paschal
Journal:  J Magn Reson Imaging       Date:  2009-09       Impact factor: 4.813

Review 3.  Virtual clinical trials in medical imaging: a review.

Authors:  Ehsan Abadi; William P Segars; Benjamin M W Tsui; Paul E Kinahan; Nick Bottenus; Alejandro F Frangi; Andrew Maidment; Joseph Lo; Ehsan Samei
Journal:  J Med Imaging (Bellingham)       Date:  2020-04-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.