Literature DB >> 18218412

MR susceptibility misregistration correction.

T S Sumanaweera1, G H Glover, T O Binford, J R Adler.   

Abstract

The authors present a new in vivo method to correct the nonlinear, object-shape-dependent and material-dependent spatial distortion in magnetic resonance (MR) images caused by magnetic susceptibility variations. This distortion across the air/tissue interface before and after the correction is quantified using a phantom. The results are compared to the distortion-free computed tomography (CT) images of the same phantom by fusing CT and MR images using fiducials, with a registration accuracy of better than a millimeter. The distortion at the bone/tissue boundary is negligible compared to the typical MRI (MR imaging) resolution of 1 mm, while that at the air/tissue boundary creates displacements of about 2 mm (for G(x) 3.13 mT/m). This is a significant value if MRI is to provide highly accurate geometric measurements, as in the case of target localization for stereotaxic surgery. The correction scheme provides MR images with accuracy similar to that of CT: 1 mm. A new method to estimate the magnetic susceptibility of materials from MR images is presented. The magnetic susceptibility of cortical bone is measured using a SQUID magnetometer, and is found to be -8.86 ppm (with respect to air), which is quite similar to that of tissue (-9 ppm).

Year:  1993        PMID: 18218412     DOI: 10.1109/42.232253

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  12 in total

Review 1.  Functional MRI for radiotherapy dose painting.

Authors:  Uulke A van der Heide; Antonetta C Houweling; Greetje Groenendaal; Regina G H Beets-Tan; Philippe Lambin
Journal:  Magn Reson Imaging       Date:  2012-07-06       Impact factor: 2.546

2.  An in vivo automated shimming method taking into account shim current constraints.

Authors:  H Wen; F A Jaffer
Journal:  Magn Reson Med       Date:  1995-12       Impact factor: 4.668

Review 3.  Current trends and challenges in MRI acquisitions to investigate brain function.

Authors:  Bradley P Sutton; Cheng Ouyang; Dimitrios C Karampinos; Gregory A Miller
Journal:  Int J Psychophysiol       Date:  2009-02-21       Impact factor: 2.997

4.  Distortion inherent to magnetic resonance imaging can lead to geometric miss in radiosurgery planning.

Authors:  Tyler M Seibert; Nathan S White; Gwe-Ya Kim; Vitali Moiseenko; Carrie R McDonald; Nikdokht Farid; Hauke Bartsch; Joshua Kuperman; Roshan Karunamuni; Deborah Marshall; Dominic Holland; Parag Sanghvi; Daniel R Simpson; Arno J Mundt; Anders M Dale; Jona A Hattangadi-Gluth
Journal:  Pract Radiat Oncol       Date:  2016-06-01

5.  In vivo validation of reconstruction-based resolution recovery for human brain studies.

Authors:  Jurgen E M Mourik; Mark Lubberink; Floris H P van Velden; Reina W Kloet; Bart N M van Berckel; Adriaan A Lammertsma; Ronald Boellaard
Journal:  J Cereb Blood Flow Metab       Date:  2009-10-21       Impact factor: 6.200

6.  Robust time-shifted spoke pulse design in the presence of large B0 variations with simultaneous reduction of through-plane dephasing, B1+ effects, and the specific absorption rate using parallel transmission.

Authors:  Bastien Guérin; Jason P Stockmann; Mehran Baboli; Angel Torrado-Carvajal; Andrew V Stenger; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2015-10-07       Impact factor: 4.668

Review 7.  [Treatment planning with functional MRI].

Authors:  P Georg; P Andrzejewski; K Pinker; D Georg
Journal:  Radiologe       Date:  2015-12       Impact factor: 0.635

8.  Simulation study of susceptibility gradients leading to focal myocardial signal loss.

Authors:  Douglas J Anderson; Jeffrey M Dendy; Cynthia B Paschal
Journal:  J Magn Reson Imaging       Date:  2008-12       Impact factor: 4.813

9.  Volume parcellation for improved dynamic shimming.

Authors:  Michael Poole; Richard Bowtell
Journal:  MAGMA       Date:  2008-01-08       Impact factor: 2.310

10.  Pitfalls in precision stereotactic surgery.

Authors:  Ludvic Zrinzo
Journal:  Surg Neurol Int       Date:  2012-01-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.