OBJECTIVE: To obtain T2* and proton density measurements of normal human lung parenchyma in vivo using submillisecond echo time (TE) gradient echo (GRE) magnetic resonance (MR) imaging.
MATERIALS AND METHODS: Six normal volunteers were scanned using a 1.5-T system equipped with a prototype enhanced gradient (GE Signa, Waukausha, WI). Images were obtained during breath-holding with acquisition times of 7-16 s. Multiple TEs ranging from 0.7 to 2.5 ms were tested. Linear regression was performed on the logarithmic plots of signal intensity versus TE, yielding measurements of T2* and proton density relative to chest wall muscle. Measurements in supine and prone position were compared, and effects of the level of lung inflation on lung signal were also evaluated.
RESULTS: The signal from the lung parenchyma diminished exponentially with prolongation of TE. The measured T2* in six normal volunteers ranged from 0.89 to 2.18 ms (1.43 +/- 0.41 ms, mean +/- S.D.). The measured relative proton density values ranged between 0.21 and 0.45 (0.29 +/- 0.08, mean +/- S.D.). Calculated T2* values of 1.46 +/- 0.50, 1.01 +/- 0.29 and 1.52 +/- 0.18 ms, and calculated relative proton densities of 0.20 +/- 0.03, 0.32 +/- 0.13 and 0.35 +/- 0.10 were obtained from the anterior, middle and posterior portions of the supine right lung, respectively. The anterior-posterior proton density gradient was reversed in the prone position. There was a pronounced increase in signal from lung parenchyma at maximum expiration compared with maximum inspiration. The ultrashort TE GRE technique yielded images demonstrating signal from lung parenchyma with minimal motion-induced noise.
CONCLUSION: Quantitative in vivo measurements of lung T2* and relative proton density in conjunction with high-signal parenchymal images can be obtained using a set of very rapid breath-hold images with a recently developed ultrashort TE GRE sequence.

Entities:  

Mesh:

Year:  1999        PMID: 10399610     DOI: 10.1016/s0720-048x(98)00169-7

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  53 in total

1.  Feasibility of combining MR perfusion, angiography, and 3He ventilation imaging for evaluation of lung function in a porcine model.

Authors:  Cheng Hong; Jason C Leawoods; Dmitriy A Yablonskiy; John R Leyendecker; Kyongtae T Bae; Thomas K Pilgram; Pamela K Woodard; Mark S Conradi; Jie Zheng
Journal:  Acad Radiol       Date:  2005-02       Impact factor: 3.173

2.  Vertical gradients in regional lung density and perfusion in the supine human lung: the Slinky effect.

Authors:  Susan R Hopkins; A Cortney Henderson; David L Levin; Kei Yamada; Tatsuya Arai; Richard B Buxton; G Kim Prisk
Journal:  J Appl Physiol (1985)       Date:  2007-03-29

3.  Pulmonary perfusion in the prone and supine postures in the normal human lung.

Authors:  G Kim Prisk; Kei Yamada; A Cortney Henderson; Tatsuya J Arai; David L Levin; Richard B Buxton; Susan R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2007-06-14

4.  Pulmonary perfusion heterogeneity is increased by sustained, heavy exercise in humans.

Authors:  K J Burnham; T J Arai; D J Dubowitz; A C Henderson; S Holverda; R B Buxton; G K Prisk; S R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2009-09-10

5.  Comparison of lung imaging using three-dimensional ultrashort echo time and zero echo time sequences: preliminary study.

Authors:  Kyungsoo Bae; Kyung Nyeo Jeon; Moon Jung Hwang; Joon Sung Lee; Ji Young Ha; Kyeong Hwa Ryu; Ho Cheol Kim
Journal:  Eur Radiol       Date:  2018-12-13       Impact factor: 5.315

6.  3D flow-independent peripheral vessel wall imaging using T(2)-prepared phase-sensitive inversion-recovery steady-state free precession.

Authors:  Jingsi Xie; Xiaoming Bi; Zhaoyang Fan; Himanshu Bhat; Saurabh Shah; Sven Zuehlsdorff; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2010-08       Impact factor: 4.813

7.  T2 mapping of CT remodelling patterns in interstitial lung disease.

Authors:  Maria T A Buzan; Monika Eichinger; Michael Kreuter; Hans-Ulrich Kauczor; Felix J Herth; Arne Warth; Carmen Monica Pop; Claus Peter Heussel; Julien Dinkel
Journal:  Eur Radiol       Date:  2015-06-03       Impact factor: 5.315

8.  Assessment of regional lung function with multivolume (1)H MR imaging in health and obstructive lung disease: comparison with (3)He MR imaging.

Authors:  Francesca Pennati; James D Quirk; Dmitriy A Yablonskiy; Mario Castro; Andrea Aliverti; Jason C Woods
Journal:  Radiology       Date:  2014-06-15       Impact factor: 11.105

9.  Hypoxic pulmonary vasoconstriction does not contribute to pulmonary blood flow heterogeneity in normoxia in normal supine humans.

Authors:  T J Arai; A C Henderson; D J Dubowitz; D L Levin; P J Friedman; R B Buxton; G K Prisk; S R Hopkins
Journal:  J Appl Physiol (1985)       Date:  2008-12-04

10.  Retrospective respiratory self-gating and removal of bulk motion in pulmonary UTE MRI of neonates and adults.

Authors:  Nara S Higano; Andrew D Hahn; Jean A Tkach; Xuefeng Cao; Laura L Walkup; Robert P Thomen; Stephanie L Merhar; Paul S Kingma; Sean B Fain; Jason C Woods
Journal:  Magn Reson Med       Date:  2016-03-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.