Literature DB >> 19023378

Experimental confirmation of potential swept source optical coherence tomography performance limitations.

Kathy Zheng1, Bin Liu, Chuanyong Huang, Mark E Brezinski.   

Abstract

Optical coherence tomography (OCT) has demonstrated considerable potential for a wide range of medical applications. Initial work was done in the time domain OCT (TD-OCT) approach, but recent interest has been generated with spectral domain OCT (SD-OCT) approaches. While SD-OCT offers higher data acquisition rates and no movable parts, we recently pointed out theoretical inferior aspects to its performance relative to TD-OCT. In this paper we focus on specific limitations of swept source OCT (SS-OCT), as this is the more versatile of the two SD-OCT embodiments. We present experimental evidence of reduced imaging penetration, increased low frequency noise, higher multiple scattering (which can be worsened still via aliasing), increased need to control the distance from the sample, and saturation of central bandwidth frequencies. We conclude that for scenarios where the dynamic range is relatively low (e.g., retina), the distance from the sample is relatively constant, or high acquisition rates are needed, SS-OCT has a role. However, when penetration remains important in the setting of a relatively high dynamic range, acquisition rates above video rate are not needed, or the distance to the tissue is not constant, TD-OCT may be the superior approach.

Entities:  

Mesh:

Year:  2008        PMID: 19023378      PMCID: PMC2640108          DOI: 10.1364/ao.47.006151

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  24 in total

1.  Monte Carlo simulation of an optical coherence tomography signal in homogeneous turbid media.

Authors:  G Yao; L V Wang
Journal:  Phys Med Biol       Date:  1999-09       Impact factor: 3.609

2.  Analysis of optical coherence tomography systems based on the extended Huygens-Fresnel principle.

Authors:  L Thrane; H T Yura; P E Andersen
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-03       Impact factor: 2.129

3.  Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies.

Authors:  C Pitris; C Jesser; S A Boppart; D Stamper; M E Brezinski; J G Fujimoto
Journal:  J Gastroenterol       Date:  2000       Impact factor: 7.527

4.  Optical coherence tomography of the esophagus and proximal stomach in health and disease.

Authors:  G Zuccaro; N Gladkova; J Vargo; F Feldchtein; E Zagaynova; D Conwell; G Falk; J Goldblum; J Dumot; J Ponsky; G Gelikonov; B Davros; E Donchenko; J Richter
Journal:  Am J Gastroenterol       Date:  2001-09       Impact factor: 10.864

5.  Removal of a mirror image and enhancement of the signal-to-noise ratio in Fourier-domain optical coherence tomography using an electro-optic phase modulator.

Authors:  Jun Zhang; J Stuart Nelson; Zhongping Chen
Journal:  Opt Lett       Date:  2005-01-15       Impact factor: 3.776

6.  Full range complex spectral optical coherence tomography technique in eye imaging.

Authors:  M Wojtkowski; A Kowalczyk; R Leitgeb; A F Fercher
Journal:  Opt Lett       Date:  2002-08-15       Impact factor: 3.776

7.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography.

Authors:  Michael Choma; Marinko Sarunic; Changhuei Yang; Joseph Izatt
Journal:  Opt Express       Date:  2003-09-08       Impact factor: 3.894

8.  Theoretical and practical considerations on detection performance of time domain, Fourier domain, and swept source optical coherence tomography.

Authors:  Bin Liu; Mark E Brezinski
Journal:  J Biomed Opt       Date:  2007 Jul-Aug       Impact factor: 3.170

9.  Optical coherence tomography for optical biopsy. Properties and demonstration of vascular pathology.

Authors:  M E Brezinski; G J Tearney; B E Bouma; J A Izatt; M R Hee; E A Swanson; J F Southern; J G Fujimoto
Journal:  Circulation       Date:  1996-03-15       Impact factor: 29.690

Review 10.  Scaffolds for articular cartilage repair.

Authors:  Sally R Frenkel; Paul E Di Cesare
Journal:  Ann Biomed Eng       Date:  2004-01       Impact factor: 3.934

View more
  4 in total

1.  Linear and planar reflection artifacts on swept-source and spectral-domain optical coherence tomography due to hyperreflective crystalline deposits.

Authors:  Serena Fragiotta; Pedro Fernández-Avellaneda; Mark P Breazzano; Lawrence A Yannuzzi; Christine A Curcio; K Bailey Freund
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2019-12-26       Impact factor: 3.117

2.  Real-time and high-performance calibration method for high-speed swept-source optical coherence tomography.

Authors:  Ehsan Azimi; Bin Liu; Mark E Brezinski
Journal:  J Biomed Opt       Date:  2010 Jan-Feb       Impact factor: 3.170

Review 3.  Optical imaging techniques for point-of-care diagnostics.

Authors:  Hongying Zhu; Serhan O Isikman; Onur Mudanyali; Alon Greenbaum; Aydogan Ozcan
Journal:  Lab Chip       Date:  2012-10-09       Impact factor: 6.799

4.  Current OCT Approaches Do Not Reliably Identify TCFAs.

Authors:  Mark E Brezinski; Kishore J Harjai
Journal:  J Clin Exp Cardiolog       Date:  2014-12-04
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.