The reliability of three-dimensional kinematic gait measurements: a systematic review.

Jennifer L McGinley1, Richard Baker, Rory Wolfe, Meg E Morris.   

Abstract

BACKGROUND/AIM: Three-dimensional kinematic measures of gait are routinely used in clinical gait analysis and provide a key outcome measure for gait research and clinical practice. This systematic review identifies and evaluates current evidence for the inter-session and inter-assessor reliability of three-dimensional kinematic gait analysis (3DGA) data.
METHOD: A targeted search strategy identified reports that fulfilled the search criteria. The quality of full-text reports were tabulated and evaluated for quality using a customised critical appraisal tool.
RESULTS: Fifteen full manuscripts and eight abstracts were included. Studies addressed both within-assessor and between-assessor reliability, with most examining healthy adults. Four full-text reports evaluated reliability in people with gait pathologies. The highest reliability indices occurred in the hip and knee in the sagittal plane, with lowest errors in pelvic rotation and obliquity and hip abduction. Lowest reliability and highest error frequently occurred in the hip and knee transverse plane. Methodological quality varied, with key limitations in sample descriptions and strategies for statistical analysis. Reported reliability indices and error magnitudes varied across gait variables and studies. Most studies providing estimates of data error reported values (S.D. or S.E.) of less than 5 degrees , with the exception of hip and knee rotation.
CONCLUSION: This review provides evidence that clinically acceptable errors are possible in gait analysis. Variability between studies, however, suggests that they are not always achieved.

Entities:  

Mesh:

Year:  2008        PMID: 19013070     DOI: 10.1016/j.gaitpost.2008.09.003

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  148 in total

1.  Local anaesthetics use does not suppress muscle activity following an ankle injection.

Authors:  David A Stone; John P Abt; Anthony J House; Jonathan S Akins; Jonathan J Pederson; Karen A Keenan; Scott M Lephart
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-04-07       Impact factor: 4.342

2.  Repeatability of electromyography recordings and muscle synergies during gait among children with cerebral palsy.

Authors:  Katherine M Steele; Meghan E Munger; Keshia M Peters; Benjamin R Shuman; Michael H Schwartz
Journal:  Gait Posture       Date:  2018-10-22       Impact factor: 2.840

3.  Inertial Sensors in Swimming: Detection of Stroke Phases through 3D Wrist Trajectory.

Authors:  Matteo Cortesi; Andrea Giovanardi; Giorgio Gatta; Anna L Mangia; Sandro Bartolomei; Silvia Fantozzi
Journal:  J Sports Sci Med       Date:  2019-08-01       Impact factor: 2.988

4.  Real-time visual feedback for gait retraining: toward application in knee osteoarthritis.

Authors:  Josien C van den Noort; Frans Steenbrink; Sanne Roeles; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2014-12-06       Impact factor: 2.602

Review 5.  Spasticity Measurement.

Authors:  Belgin Petek Balci
Journal:  Noro Psikiyatr Ars       Date:  2018       Impact factor: 1.339

6.  Random forest-based classsification and analysis of hemiplegia gait using low-cost depth cameras.

Authors:  Guoliang Luo; Yean Zhu; Rui Wang; Yang Tong; Wei Lu; Haolun Wang
Journal:  Med Biol Eng Comput       Date:  2019-12-18       Impact factor: 2.602

7.  Hamstring tendon anterior cruciate ligament reconstruction: does gracilis tendon harvest matter?

Authors:  Björn Barenius; Webster Kate Webster; Jodie McClelland; Julian Feller
Journal:  Int Orthop       Date:  2012-10-11       Impact factor: 3.075

8.  Reliability and precision of 3D wireless measurement of scapular kinematics.

Authors:  Josien C van den Noort; Suzanne H Wiertsema; Karin M C Hekman; Casper P Schönhuth; Joost Dekker; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2014-09-06       Impact factor: 2.602

9.  Gait analysis in children with cerebral palsy via inertial and magnetic sensors.

Authors:  Josien C van den Noort; Alberto Ferrari; Andrea G Cutti; Jules G Becher; Jaap Harlaar
Journal:  Med Biol Eng Comput       Date:  2012-12-09       Impact factor: 2.602

10.  A comparison of foot arch measurement reliability using both digital photography and calliper methods.

Authors:  Michael B Pohl; Lindsay Farr
Journal:  J Foot Ankle Res       Date:  2010-07-14       Impact factor: 2.303

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.