Literature DB >> 19011166

Ex vivo surface and mechanical properties of coated orthodontic archwires.

Firas Elayyan1, Nick Silikas, David Bearn.   

Abstract

This study examined the mechanical and physical properties of retrieved coated nickel-titanium (NiTi) archwires compared with unused samples. Ultraesthetic 0.016 inch coated archwires (G&H(R) Wire Company) were investigated. Ten as-received wires were subjected to a three-point bending test using conventional and self-ligating bracket systems. Surface roughness of the coating was measured with a contact stylus profilometer. Optical and scanning electron microscopes were used to assess surface topography. Ten archwires were used in vivo for a period of between 4 and 6 weeks. Retrieved archwires were subjected to the same tests. The percentage of the remaining coating was calculated using digital photography. Coated archwires were used in vivo for a mean period of 33 days. Differences between the mean values of the as-received and retrieved archwires were determined using t-tests. In the three-point bending test, with conventional elastomeric ligation, retrieved wires produced a lower unloading force (P < 0.001). Both retrieved and as-received coated archwires produced zero values of unloading force when deflected for 4 mm. When tested using a self-ligating bracket system, retrieved and as-received coated archwires produced the same amount of force (P > 0.05). With surface profilometry, all measured roughness parameters (except R(sm)) had greater surface roughness for the retrieved coated archwires (P < 0.05). Under microscopy, retrieved coated archwires showed discolouration, ditching, and delamination. Only 75 per cent of the coating was present in retrieved coated archwires. Retrieved coated archwires produced lower unloading force values than as-received coated archwires with conventional ligation. Surface roughness of coated archwires increased after use. Coated archwires have a low aesthetic value, with 25 per cent of the coating lost within 33 days in vivo.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 19011166     DOI: 10.1093/ejo/cjn057

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  27 in total

1.  Comparison of the Load-Deflection Characteristics of Aesthetic and Conventional Super Elastic Ni-Ti Orthodontic Arch Wires in Conventional and Metal-Insert Ceramic Brackets.

Authors:  Hosseinagha Aghili; Soghra Yassaei; Neda Joshan; Nemat Hoseini
Journal:  J Clin Diagn Res       Date:  2016-12-01

2.  Comparison of frictional resistance between self-ligating and conventional brackets tied with elastomeric and metal ligature in orthodontic archwires.

Authors:  Vanessa Vieira Leite; Murilo Baena Lopes; Alcides Gonini Júnior; Marcio Rodrigues de Almeida; Sandra Kiss Moura; Renato Rodrigues de Almeida
Journal:  Dental Press J Orthod       Date:  2014 May-Jun

3.  Friction behavior of self-ligating and conventional brackets with different ligature systems.

Authors:  Alexandra Szczupakowski; Susanne Reimann; Cornelius Dirk; Ludger Keilig; Anna Weber; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-05-24       Impact factor: 1.938

4.  Mechanical properties of different esthetic and conventional orthodontic wires in bending tests : An in vitro study.

Authors:  Ahmad Alobeid; Cornelius Dirk; Susanne Reimann; Tarek El-Bialy; Andreas Jäger; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-12-09       Impact factor: 1.938

5.  Comparison of frictional forces between aesthetic orthodontic coated wires and self-ligation brackets.

Authors:  Yunmi Kim; Jung-Yul Cha; Chung-Ju Hwang; Hyung Seog Yu; Seon Gun Tahk
Journal:  Korean J Orthod       Date:  2014-07-24       Impact factor: 1.372

6.  Mechanical properties of orthodontic wires covered with a polyether ether ketone tube.

Authors:  Nobukazu Shirakawa; Toshio Iwata; Shinjiro Miyake; Takero Otuka; So Koizumi; Toshitugu Kawata
Journal:  Angle Orthod       Date:  2018-03-21       Impact factor: 2.079

7.  Relationship between friction force and orthodontic force at the leveling stage using a coated wire.

Authors:  Masaki Murayama; Yasuhiro Namura; Takahiko Tamura; Hiroaki Iwai; Noriyoshi Shimizu
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

8.  Color stability and fluorescence of different orthodontic esthetic archwires.

Authors:  Dayanne Lopes da Silva; Claudia Trindade Mattos; Marcus Vinicius Almeida de Araújo; Antônio Carlos de Oliveira Ruellas
Journal:  Angle Orthod       Date:  2012-05-14       Impact factor: 2.079

9.  Effect of coating on properties of esthetic orthodontic nickel-titanium wires.

Authors:  Masahiro Iijima; Takeshi Muguruma; William Brantley; Han-Cheol Choe; Susumu Nakagaki; Satish B Alapati; Itaru Mizoguchi
Journal:  Angle Orthod       Date:  2011-08-09       Impact factor: 2.079

10.  Effects of intraoral aging on surface properties of coated nickel-titanium archwires.

Authors:  Roberto Rongo; Gianluca Ametrano; Antonio Gloria; Gianrico Spagnuolo; Angela Galeotti; Sergio Paduano; Rosa Valletta; Vincenzo D'Antò
Journal:  Angle Orthod       Date:  2013-12-05       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.