N Fukuda1, H Tanaka, Y Shoyama.
Abstract
The ratio of hapten and bovine serum albumin in an antigenconjugate was determined by matrix-assisted laserdesorption/ionization time-of-flight mass spectrometry. Ahybridoma secreting monoclonal antibody against ginsenosideRg(1) was produced by fusing sprenocytes immunized with aginsenoside Rg(1)-bovine serum albumin conjugate withHAT-sensitive mouse myeloma cell line, P3-X63-Ag8-653. A very smallcross-reaction appeared with ginsenoside Re. The full measuringrange of the assay extends from 0.3 mug ml(-1) to 10 mug ml(-1) ofginsenoside Rg(1).Entities:
Year: 2000 PMID: 19003395 PMCID: PMC3449635 DOI: 10.1023/A:1008162703957
Source DB: PubMed Journal: Cytotechnology ISSN: 0920-9069 Impact factor: 2.058