Literature DB >> 19001653

3.0-T MR imaging of the abdomen: comparison with 1.5 T.

Kevin J Chang1, Ihab R Kamel, Katarzyna J Macura, David A Bluemke.   

Abstract

Three-tesla magnetic resonance (MR) imaging offers substantially higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than 1.5-T MR imaging does, which can be used to improve image resolution and shorten imaging time. Because of these increases in SNR and CNR, as well as changes in T1 and T2 relaxation times, an increase in magnetic susceptibility, and an increase in chemical shift effect, many abdominal applications can benefit from 3.0-T imaging. Increased CNR obtained with a gadolinium-based contrast agent improves lesion conspicuity, requires less intravenous contrast material, and improves MR angiography by increasing spatial and temporal resolution. Increased SNR improves fluid conspicuity and resolution for applications such as MR cholangiopancreatography. Increased chemical shift effect also improves spectral resolution for MR spectroscopy. Several potential problems remain for abdominal imaging at 3.0 T. Limitations on energy deposition may require compromises in pulse sequence timing and flip angles. These compromises result in prolonged imaging time and altered image contrast. Magnetic susceptibility and chemical shift artifacts are worsened, but they may be counteracted by shortening echo time, performing parallel imaging, and increasing bandwidth. Radiofrequency field inhomogeneity is also a major concern in imaging larger fields of view and often leads to standing wave effects and large local variations in signal intensity. Many issues related to MR device compatibility and safety have yet to be addressed at 3.0 T. A 3.0-T MR imaging system has a higher initial cost and a higher cost of upkeep than a 1.5-T system does.

Entities:  

Mesh:

Year:  2008        PMID: 19001653     DOI: 10.1148/rg.287075154

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  52 in total

1.  Small (≤ 2 cm) hepatocellular carcinoma in patients with chronic liver disease: comparison of gadoxetic acid-enhanced 3.0 T MRI and multiphasic 64-multirow detector CT.

Authors:  J Hwang; S H Kim; M W Lee; J Y Lee
Journal:  Br J Radiol       Date:  2011-12-13       Impact factor: 3.039

Review 2.  MRI in Crohn's disease--current and future clinical applications.

Authors:  Gionata Fiorino; Cristiana Bonifacio; Alberto Malesci; Luca Balzarini; Silvio Danese
Journal:  Nat Rev Gastroenterol Hepatol       Date:  2011-11-22       Impact factor: 46.802

3.  Unenhanced calf MR angiography at 3.0 T using electrocardiography-gated partial-fourier fast spin echo imaging with variable flip angle.

Authors:  Dan Li; Jiang Lin; Fuhua Yan; Qingyuan Wu; Weiwei Lv; Yan San; Hong Yun
Journal:  Eur Radiol       Date:  2010-12-14       Impact factor: 5.315

4.  Comparative study of image quality between axial T2-weighted BLADE and turbo spin-echo MRI of the upper abdomen on 3.0 T.

Authors:  Lin Zhang; ChunMei Tian; PeiYuan Wang; Liang Chen; XiJin Mao; ShanShan Wang; Xu Wang; JingMin Dong; Bin Wang
Journal:  Jpn J Radiol       Date:  2015-08-02       Impact factor: 2.374

5.  3.0 Tesla magnetic resonance imaging: A new standard in liver imaging?

Authors:  Rossano Girometti
Journal:  World J Hepatol       Date:  2015-07-28

6.  Breast MRI at 7 Tesla with a bilateral coil and robust fat suppression.

Authors:  Ryan Brown; Pippa Storey; Christian Geppert; KellyAnne McGorty; Ana Paula Klautau Leite; James Babb; Daniel K Sodickson; Graham C Wiggins; Linda Moy
Journal:  J Magn Reson Imaging       Date:  2013-10-07       Impact factor: 4.813

Review 7.  [New developments in MRI of the liver].

Authors:  N Bastati-Huber; H Prosch; S Baroud; S Magnaldi; W Schima; A Ba-Ssalamah
Journal:  Radiologe       Date:  2011-08       Impact factor: 0.635

Review 8.  Image-quality optimization and artifact reduction in fetal magnetic resonance imaging.

Authors:  Fedel Machado-Rivas; Camilo Jaimes; John E Kirsch; Michael S Gee
Journal:  Pediatr Radiol       Date:  2020-11-30

9.  Seven-Tesla MRI of the female pelvis.

Authors:  Lale Umutlu; Oliver Kraff; Anja Fischer; Sonja Kinner; Stefan Maderwald; Kai Nassenstein; Felix Nensa; Johannes Grüneisen; Stephan Orzada; Andreas K Bitz; Michael Forsting; Mark E Ladd; Thomas C Lauenstein
Journal:  Eur Radiol       Date:  2013-05-04       Impact factor: 5.315

Review 10.  Magnetic resonance evaluations of biliary malignancy and condition at high-risk for biliary malignancy: Current status.

Authors:  Reiji Sugita
Journal:  World J Hepatol       Date:  2013-12-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.