Real-time three-dimensional intracardiac echocardiography.

E D Light1, S F Idriss, P D Wolf, S W Smith.   

Abstract

Using catheter-mounted 2-D array transducers, we have obtained real-time 3-D intracardiac ultrasound (US) images. We have constructed several transducers with 64 channels inside a 12 French catheter lumen operating at 5 MHz. The transducer configuration may be side-scanning or beveled, with respect to the long axis of the catheter lumen. We have also included six electrodes to acquire simultaneous electrocardiograms. Using an open-chest sheep model, we inserted the catheter into the cardiac chambers to study the utility of in vivo intracardiac 3-D scanning. Images obtained include a cardiac four-chamber view, mitral valve, pulmonic valve, tricuspid valve, interatrial septum, interventricular septum and ventricular volumes. We have also imaged two electrophysiological interventional devices in the right atrium, performed an in vitro ablation study, and viewed the pulmonary veins in vitro.

Entities:  

Mesh:

Year:  2001        PMID: 11597357     DOI: 10.1016/s0301-5629(01)00421-5

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Real-time 3-d intracranial ultrasound with an endoscopic matrix array transducer.

Authors:  Edward D Light; Srinivasan Mukundan; Patrick D Wolf; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2007-05-03       Impact factor: 2.998

2.  Clinical advantage of real-time three-dimensional transesophageal echocardiography for transcatheter closure of multiple atrial septal defects.

Authors:  Manabu Taniguchi; Teiji Akagi; Yasufumi Kijima; Shunji Sano
Journal:  Int J Cardiovasc Imaging       Date:  2013-04-23       Impact factor: 2.357

3.  Real-time 3-D ultrasound guidance of interventional devices.

Authors:  Edward D Light; John F Angle; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-09       Impact factor: 2.725

4.  Experimental studies with a 9F forward-looking intracardiac imaging and ablation catheter.

Authors:  Douglas N Stephens; Matthew O'Donnell; Kai Thomenius; Aaron Dentinger; Douglas Wildes; Peter Chen; K Kirk Shung; Jonathan Cannata; Pierre Khuri-Yakub; Omer Oralkan; Aman Mahajan; Kalyanam Shivkumar; David J Sahn
Journal:  J Ultrasound Med       Date:  2009-02       Impact factor: 2.153

5.  Assessment of normal tricuspid valve anatomy in adults by real-time three-dimensional echocardiography.

Authors:  Ashraf M Anwar; Marcel L Geleijnse; Osama I I Soliman; Jackie S McGhie; René Frowijn; Attila Nemes; Annemien E van den Bosch; Tjebbe W Galema; Folkert J Ten Cate
Journal:  Int J Cardiovasc Imaging       Date:  2007-02-23       Impact factor: 2.357

6.  Experimental 3-D Ultrasound Imaging with 2-D Sparse Arrays using Focused and Diverging Waves.

Authors:  Emmanuel Roux; François Varray; Lorena Petrusca; Christian Cachard; Piero Tortoli; Hervé Liebgott
Journal:  Sci Rep       Date:  2018-06-14       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.