Literature DB >> 18977634

Long-term remodeling in proximal femur around a hydroxyapatite-coated anatomic stem: ten years densitometric follow-up.

Juan J Panisello1, Luis Herrero, Vicente Canales, Antonio Herrera, Angel A Martínez, Jesús Mateo.   

Abstract

Bone remodeling after a hip arthroplasty has been quantified with dual energy x-ray absorptiometry, usually for short-term follow-up. We used this technique to determine the long-term remodeling produced by a hydroxyapatite-coated, anatomic stem. Eighty patients with unilateral hip osteoarthritis were included in the study. The contralateral, healthy hip was taken as control. Bilateral dual energy x-ray absorptiometry scans were done before the surgery, at 15 days, and 1 and 10 years postoperatively. There was a decrease of bone mineral density in zones 1 and 7, which ranged from 12.2% to 27.3% at the end of the first year. There were no changes in zones 1 to 6 from the 1st to the 10th year, but there was a late decrease, up to 42.9%, in zone 7. The changes of bone mineral density promoted by this stem occurred in the first postoperative year. Late loss was seen only in area 7.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18977634     DOI: 10.1016/j.arth.2007.12.017

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Study of bone remodeling of two models of femoral cementless stems by means of DEXA and finite elements.

Authors:  Luis Gracia; Elena Ibarz; Sergio Puértolas; José Cegoñino; Fernando López-Prats; Juan J Panisello; Antonio Herrera
Journal:  Biomed Eng Online       Date:  2010-05-28       Impact factor: 2.819

2.  Extended sagittal saw cut significantly reduces fracture load in cementless unicompartmental knee arthroplasty compared to cemented tibia plateaus: an experimental cadaver study.

Authors:  J B Seeger; D Haas; S Jäger; E Röhner; S Tohtz; M Clarius
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-10-15       Impact factor: 4.342

3.  Applications of finite element simulation in orthopedic and trauma surgery.

Authors:  Antonio Herrera; Elena Ibarz; José Cegoñino; Antonio Lobo-Escolar; Sergio Puértolas; Enrique López; Jesús Mateo; Luis Gracia
Journal:  World J Orthop       Date:  2012-04-18

4.  Is there any difference between tapered titanium stems with similar geometry and hydroxyapatite coating?

Authors:  G Cinotti; G Mazzotta; F Romana Ripani; G La Torre; G Giannicola
Journal:  Musculoskelet Surg       Date:  2019-01-08

5.  Development of periprosthetic bone mass density around the cementless Metha® short hip stem during three year follow up-a prospective radiological and clinical study.

Authors:  Laura Augustin; Sarah Boller; Cathrein Bobach; Alexander Jahnke; Gafar Adam Ahmed; Markus Rickert; Bernd Alexander Ishaque
Journal:  Int Orthop       Date:  2018-09-03       Impact factor: 3.075

6.  Bone remodeling around stable uncemented titanium stems during the second decade after total hip arthroplasty: a DXA study at 12 and 17 years.

Authors:  C Merle; M R Streit; C Volz; M Pritsch; T Gotterbarm; P R Aldinger
Journal:  Osteoporos Int       Date:  2010-11-23       Impact factor: 4.507

7.  Periprosthetic bone loss after insertion of an uncemented, customized femoral stem and an uncemented anatomical stem. A randomized DXA study with 5-year follow-up.

Authors:  Mona Nysted; Pål Benum; Jomar Klaksvik; Olav Foss; Arild Aamodt
Journal:  Acta Orthop       Date:  2011-06-14       Impact factor: 3.717

8.  Cementless hydroxyapatite coated hip prostheses.

Authors:  Antonio Herrera; Jesús Mateo; Jorge Gil-Albarova; Antonio Lobo-Escolar; Elena Ibarz; Sergio Gabarre; Yolanda Más; Luis Gracia
Journal:  Biomed Res Int       Date:  2015-02-23       Impact factor: 3.411

9.  Continuous periprosthetic bone loss but preserved stability for a collum femoris-preserving stem: follow-up of a prospective cohort study of 21 patients with dualenergy X-ray absorptiometry and radiostereometric analysis with minimum 8 years of follow-up.

Authors:  Andreas Nyström; Demostenis Kiritopoulos; Hans Mallmin; Stergios Lazarinis
Journal:  Acta Orthop       Date:  2022-01-03       Impact factor: 3.717

  9 in total