The effect of breast compression on mass conspicuity in digital mammography.

Robert S Saunders1, Ehsan Samei.   

Abstract

This study analyzed how the inherent quality of diagnostic information in digital mammography could be affected by breast compression. A digital mammography system was modeled using a Monte Carlo algorithm based on the Penelope program, which has been successfully used to model several medical imaging systems. First, the Monte Carlo program was validated against previous measurements and simulations. Once validated, the Monte Carlo software modeled a digital mammography system by tracking photons through a voxelized software breast phantom, containing anatomical structures and breast masses, and following photons until they were absorbed by a selenium-based flat-panel detector. Simulations were performed for two compression conditions (standard compression and 12.5% reduced compression) and three photon flux conditions (constant flux, constant detector signal, and constant glandular dose). The results showed that reduced compression led to higher scatter fractions, as expected. For the constant photon flux condition, decreased compression also reduced glandular dose. For constant glandular dose, the SdNR for a 4 cm breast was 0.60 +/- 0.11 and 0.62 +/- 0.11 under standard and reduced compressions, respectively. For the 6 cm case with constant glandular dose, the SdNR was 0.50 +/- 0.11 and 0.49 +/- 0.10 under standard and reduced compressions, respectively. The results suggest that if a particular imaging system can handle an approximately 10% increase in total tube output and 10% decrease in detector signal, breast compression can be reduced by about 12% in terms of breast thickness with little impact on image quality or dose.

Entities:  

Mesh:

Year:  2008        PMID: 18975694     DOI: 10.1118/1.2977600

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  MCAT to XCAT: The Evolution of 4-D Computerized Phantoms for Imaging Research: Computer models that take account of body movements promise to provide evaluation and improvement of medical imaging devices and technology.

Authors:  W Paul Segars; Benjamin M W Tsui
Journal:  Proc IEEE Inst Electr Electron Eng       Date:  2009-12       Impact factor: 10.961

2.  Effects of Reduced Compression in Digital Breast Tomosynthesis on Pain, Anxiety, and Image Quality.

Authors:  Siti Aishah Abdullah Suhaimi; Afifah Mohamed; Mahadir Ahmad; Kanaga Kumari Chelliah
Journal:  Malays J Med Sci       Date:  2015-11

3.  Contrast detail phantom comparison on a commercially available unit. Digital breast tomosynthesis (DBT) versus full-field digital mammography (FFDM).

Authors:  Marco Bertolini; Andrea Nitrosi; Giovanni Borasi; Andrea Botti; Davide Tassoni; Roberto Sghedoni; Giulio Zuccoli
Journal:  J Digit Imaging       Date:  2011-02       Impact factor: 4.056

4.  Pain-preventing strategies in mammography: an observational study of simultaneously recorded pain and breast mechanics throughout the entire breast compression cycle.

Authors:  Jerry E de Groot; Mireille J M Broeders; Cornelis A Grimbergen; Gerard J den Heeten
Journal:  BMC Womens Health       Date:  2015-03-15       Impact factor: 2.809

5.  Influence of breast compression pressure on the performance of population-based mammography screening.

Authors:  Katharina Holland; Ioannis Sechopoulos; Ritse M Mann; Gerard J den Heeten; Carla H van Gils; Nico Karssemeijer
Journal:  Breast Cancer Res       Date:  2017-11-28       Impact factor: 6.466

6.  Mammographic compression in Asian women.

Authors:  Susie Lau; Yang Faridah Abdul Aziz; Kwan Hoong Ng
Journal:  PLoS One       Date:  2017-04-18       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.