Literature DB >> 18975681

Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Reshma Munbodh1, Zhe Chen, David A Jaffray, Douglas J Moseley, Jonathan P S Knisely, James S Duncan.   

Abstract

In prostate radiotherapy, setup errors with respect to the patient's bony anatomy can be reduced by aligning 2D megavoltage (MV) portal images acquired during treatment to a reference 3D kilovoltage (kV) CT acquired for treatment planning purposes. The purpose of this study was to evaluate a fully automated 2D-3D registration algorithm to quantify setup errors in 3D through the alignment of line-enhanced portal images and digitally reconstructed radiographs computed from the CT. The line-enhanced images were obtained by correlating the images with a filter bank of short line segments, or "sticks" at different orientations. The proposed methods were validated on (1) accurately collected gold-standard data consisting of a 3D kV cone-beam CT scan of an anthropomorphic phantom of the pelvis and 2D MV portal images in the anterior-posterior (AP) view acquired at 15 different poses and (2) a conventional 3D kV CT scan and weekly 2D MV AP portal images of a patient over 8 weeks. The mean (and standard deviation) of the absolute registration error for rotations around the right-lateral (RL), inferior-superior (IS), and posterior-anterior (PA) axes were 0.212 degree (0.214 degree), 0.055 degree (0.033 degree) and 0.041 degree (0.039 degree), respectively. The corresponding registration errors for translations along the RL, IS, and PA axes were 0.161 (0.131) mm, 0.096 (0.033) mm, and 0.612 (0.485) mm. The mean (and standard deviation) of the total registration error was 0.778 (0.543) mm. Registration on the patient images was successful in all eight cases as determined visually. The results indicate that it is feasible to automatically enhance features in MV portal images of the pelvis for use within a completely automated 2D-3D registration framework for the accurate determination of patient setup errors. They also indicate that it is feasible to estimate all six transformation parameters from a 3D CT of the pelvis and a single portal image in the AP view.

Entities:  

Mesh:

Year:  2008        PMID: 18975681      PMCID: PMC3910153          DOI: 10.1118/1.2975143

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  37 in total

1.  A minimax entropy registration framework for patient setup verification in radiotherapy.

Authors:  R Bansal; L Staib; Z Chen; A Rangarajan; J Knisely; R Nath; J Duncan
Journal:  Comput Aided Surg       Date:  1999

2.  3-D/2-D registration of CT and MR to X-ray images.

Authors:  Dejan Tomazevic; Bostjan Likar; Tomaz Slivnik; Franjo Pernus
Journal:  IEEE Trans Med Imaging       Date:  2003-11       Impact factor: 10.048

3.  A new algorithm for the registration of portal images to planning images in the verification of radiotherapy, as validated in prostate treatments.

Authors:  Mark Jobse; Jaap Davelaar; Emile Hendriks; Rob Kattevilder; Hans Reiber; Berend Stoel
Journal:  Med Phys       Date:  2003-09       Impact factor: 4.071

4.  Evaluation of cost functions for gray value matching of two-dimensional images in radiotherapy.

Authors:  Niels Dekker; Lennert S Ploeger; Marcel van Herk
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

5.  Automatic registration of portal images and volumetric CT for patient positioning in radiation therapy.

Authors:  Ali Khamene; Peter Bloch; Wolfgang Wein; Michelle Svatos; Frank Sauer
Journal:  Med Image Anal       Date:  2005-09-08       Impact factor: 8.545

6.  Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.

Authors:  Reshma Munbodh; David A Jaffray; Douglas J Moseley; Zhe Chen; Jonathan P S Knisely; Pascal Cathier; James S Duncan
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

7.  A simple algorithm for planar image registration in radiation therapy.

Authors:  J Cai; J C Chu; V A Saxena; L H Lanzl
Journal:  Med Phys       Date:  1998-06       Impact factor: 4.071

8.  Least-squares fitting of two 3-d point sets.

Authors:  K S Arun; T S Huang; S D Blostein
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  1987-05       Impact factor: 6.226

9.  Three-dimensional verification of patient placement during radiotherapy using portal images.

Authors:  J Bijhold
Journal:  Med Phys       Date:  1993 Mar-Apr       Impact factor: 4.071

10.  Patient setup error measurement using 3D intensity-based image registration techniques.

Authors:  Sébastien Clippe; David Sarrut; Claude Malet; Serge Miguet; Chantal Ginestet; Christian Carrie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

View more
  2 in total

1.  Registration of clinical volumes to beams-eye-view images for real-time tracking.

Authors:  Jonathan H Bryant; Joerg Rottmann; John H Lewis; Pankaj Mishra; Paul J Keall; Ross I Berbeco
Journal:  Med Phys       Date:  2014-12       Impact factor: 4.071

2.  C-arm Positioning Using Virtual Fluoroscopy for Image-Guided Surgery.

Authors:  T De Silva; J Punnoose; A Uneri; J Goerres; M Jacobson; M D Ketcha; A Manbachi; S Vogt; G Kleinszig; A J Khanna; J-P Wolinksy; G Osgood; J H Siewerdsen
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.