Literature DB >> 12772984

Evaluation of cost functions for gray value matching of two-dimensional images in radiotherapy.

Niels Dekker1, Lennert S Ploeger, Marcel van Herk.   

Abstract

In external beam radiotherapy, portal imaging is applied for verification of the patient setup. Current automatic methods for portal image registration, which are often based on segmentation of anatomical structures, are especially successful for images of the pelvic region. For portal images of more complicated anatomical structures, e.g., lung, these techniques are less successful. It is desirable to have a method for image registration that is applicable for a wide range of treatment sites. In this study, a registration method for two-dimensional (2D) registration of portal and reference images based on intensity values was tested on portal images of various anatomical sites. Tests were performed with and without preprocessing (unsharp mask filtering followed by histogram equalization) for 96 image pairs and six cost functions. The images were obtained from treatments of the rectum, salivary gland, brain, prostate, and lung. To get insight into the behavior of the various cost functions, cost function values were computed for each portal image for 20,000 transformations of the corresponding reference image, translating the reference image in a range of +/- 1 cm and rotating +/- 10 degrees with respect to the clinical match. The automatic match was defined as the transformation associated with the global minimum (found by an exhaustive search). Without preprocessing, the registration reliability was low (less than 27%). With preprocessing, about 90% of the matches were successful, with a difference with our gold standard (manual registration) of about 1 mm and 1 degree SD. All tested cost functions performed similarly. However, the number of local minima using mutual information was larger than for the other tested cost functions. A cost function based on the mean product of the corresponding pixel values had the least number of local minima. In conclusion, gray value based registration of portal images is applicable for a wide range of treatment sites. However, pre-processing of the images is essential.

Entities:  

Mesh:

Year:  2003        PMID: 12772984     DOI: 10.1118/1.1567272

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Automated 2D-3D registration of a radiograph and a cone beam CT using line-segment enhancement.

Authors:  Reshma Munbodh; David A Jaffray; Douglas J Moseley; Zhe Chen; Jonathan P S Knisely; Pascal Cathier; James S Duncan
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

2.  A frequency-based approach to locate common structure for 2D-3D intensity-based registration of setup images in prostate radiotherapy.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

3.  Automated 2D-3D registration of portal images and CT data using line-segment enhancement.

Authors:  Reshma Munbodh; Zhe Chen; David A Jaffray; Douglas J Moseley; Jonathan P S Knisely; James S Duncan
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

4.  Evaluating the effect of image preprocessing on an information-theoretic CAD system in mammography.

Authors:  Georgia D Tourassi; Robert Ike; Swatee Singh; Brian Harrawood
Journal:  Acad Radiol       Date:  2008-05       Impact factor: 3.173

5.  An automatic correction method for the heel effect in digitized mammography images.

Authors:  Marcelo Zanchetta do Nascimento; Annie France Frère; Fernao Germano
Journal:  J Digit Imaging       Date:  2007-09-11       Impact factor: 4.056

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.