Literature DB >> 18969211

An initial-rate potentiometric method for the determination of uric acid using a fluoride ion-selective electrode.

Farzad Deyhimi1, Rahman Salamat-Ahangari.   

Abstract

The principle of a general potentiometric method based on Emerson-Trinder reaction for the assay of various hydrogen peroxide generating systems is reported. Emerson-Trinder reaction, habitually employed as a spectrophotometric indicator reaction, is exploited in this method as a potentiometric indicator reaction. This method is based on the detection of F(-) ions, liberated from the oxidation of a fluorophenol compound used as hydrogen-donor in Emerson-Trinder reaction, by a fluoride ion-selective electrode. The ability and usefulness of this method are illustrated by an initial-rate potentiometric determination of uric acid in aqueous and human serum samples, for which, initial-rate reaction progress curves, linear calibration curve, within-day precisions, upper and lower detection limits, and also its analytical recovery were reported.

Entities:  

Year:  2003        PMID: 18969211     DOI: 10.1016/S0039-9140(03)00309-6

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Degradation studies of transparent conductive electrodes on electroactive poly(vinylidene fluoride) for uric acid measurements.

Authors:  Vanessa F Cardoso; Pedro Martins; Gabriela Botelho; Luis Rebouta; Senentxu Lanceros-Méndez; Graca Minas
Journal:  Sci Technol Adv Mater       Date:  2010-10-19       Impact factor: 8.090

2.  Determination of glucose using a coupled-enzymatic reaction with new fluoride selective optical sensing polymeric film coated in microtiter plate wells.

Authors:  Hisham S M Abd-Rabboh; Mark E Meyerhoff
Journal:  Talanta       Date:  2007-05-15       Impact factor: 6.057

3.  A potentiometric indirect uric acid sensor based on ZnO nanoflakes and immobilized uricase.

Authors:  Syed M Usman Ali; Zafar Hussain Ibupoto; Muhammad Kashif; Uda Hashim; Magnus Willander
Journal:  Sensors (Basel)       Date:  2012-03-01       Impact factor: 3.576

4.  Synthesis of Heart/Dumbbell-Like CuO Functional Nanostructures for the Development of Uric Acid Biosensor.

Authors:  Zafar Hussain Ibupoto; Aneela Tahira; Hamid Raza; Gulzar Ali; Aftab Ahmed Khand; Nabila Shah Jilani; Arfana Begum Mallah; Cong Yu; Magnus Willander
Journal:  Materials (Basel)       Date:  2018-08-08       Impact factor: 3.623

5.  Fluoride Burden of Aluminum Plant Workers.

Authors:  Jun Tu; Ke-Jian Liu; Long-Ju Ran; Xing-Ping Pan
Journal:  Iran J Public Health       Date:  2015-04       Impact factor: 1.429

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.