Literature DB >> 26056678

Fluoride Burden of Aluminum Plant Workers.

Jun Tu1, Ke-Jian Liu2, Long-Ju Ran1, Xing-Ping Pan1.   

Abstract

Entities:  

Year:  2015        PMID: 26056678      PMCID: PMC4441972     

Source DB:  PubMed          Journal:  Iran J Public Health        ISSN: 2251-6085            Impact factor:   1.429


× No keyword cloud information.

Dear Editor-in-Chief

Fluoride (F), a powerful oxidizing agent, is used in a variety of industries in China. Health problems among industrial workers due to F poisoning are on the rise. Long-term F exposure, together with varieties of relevant factors, leads to high F burden [blood fluoride (BF), urinary fluoride (UF)], which can finally result in F bone injury (1). As F burden is the major cause of F bone injury, to prevent the F bone injury, we have to control the F burden to a moderate level. The purpose of the present study was to examine the F burden and relevant factors of aluminum plant workers, and provide the basis for the early prevention of F bone injury. Overall, 300 subjects, 20 to 50 of age, were randomly selected from workshops of an aluminum plant, who have been working in their present position for 5 years or longer. We conducted a face-to-face questionnaire for the 300 subjects. After finishing the questionnaire, only 279 subjects were included in our study. The participating subjects signed informed consent forms. Blood samples were collected from a brachial vein within a few minutes after the end of the shift. Urine samples were collected as follows: just before the afternoon half-shift, the workers were asked to empty their bladders; then a sample of urine was collected at the end of the shift, just after blood drawing. Blood and urine samples were kept refrigerated until analysis. Air samples were collected from 6 different points in each workshop 16 times per day, for two consecutive days. The levels of BF and UF were determined by fluoride ion-selective electrode method. Levels of AF were determined by filter sampling and fluoride ion-selective electrode method (2, 3). This study was approved by the Institutional Ethical Boards of Tongji Medical College, Wuhan China, and had been performed in accordance with the ethical standards laid down in the 1964 Declaration of Helsinki and its later amendments. Statistical analyses were performed using SPSS 16.0 statistical software. The highest AF was observed in aluminum electrolytic workshop (2.31±1.01mg/m3), followed by aluminum pole workshop (0.36±0.10mg/m3), the lowest observed in the office area (0.11±0.09mg/m3). The differences among the three workshops were significant (P<0.01).Means and standard deviations of BF and UF levels are presented in Table 1, for workers classified by different factors. Results showed that BF of aluminum electrolytic workers were significantly higher than that of aluminum pole workers and that of office workers (P<0.01); BF of aluminum pole workers were significantly higher than that of office workers (P<0.01). UF of aluminum electrolytic workers were significantly higher than that of aluminum pole workers and that of office workers (P<0.01); UF of aluminum pole workers were significantly higher than that of office workers (P<0.01). Age, Working history, smoking and alcohol consumption did not significantly affect the BF and UF levels (P>0.05).
Table 1:

BF and UF levels (mean ± SD, mg/L) in relation to different factors

FactorsnBFa(mean ± SD)UFa(mean ± SD)
All subjects2790.20±0.064.49±4.49
Work category
1. Office workers (af: 0.11±0.09mg/m3)940.06±0.021.32±0.87
2. Aluminum pole workers (af: 0.36±0.10mg/m3)900.12±0.03 b2.85±1.94 b
3. Aluminum electrolytic workers (af: 2. 31±1.01mg/m3)950.21±0.06bc7.13±5.72bc
Age(yr)
1. <30890.20±0.056.92±5.62
2. 30∼401020.19±0.055.92±4.68
3. >40880.22±0.075.82±5.52
Working history(yr)
1. <10920.21±0.065.78±5.28
2. 10∼201130.19±0.054.20±4.18
3. >20740.22±0.074.65±4.04
Smoking
1. Never smoker990.20±0.054.61±4.80
2. Non-daily smoker690.19±0.063.17±1.99
3. Daily smoker1110.20±0.064.61±4.49
Alcohol consumption
1. Never consumer620.20±0.064.55±4.92
2. Non-daily consumer1010.20±0.064.25±4.24
3. Daily consumer1160.20±0.055.06±4.66

BF, blood fluoride level; UF, urinary fluoride level;

compare with work category 1, P<0.01 by ANOVA;

compare with work category 2, P<0.01 by ANOVA

BF and UF levels (mean ± SD, mg/L) in relation to different factors BF, blood fluoride level; UF, urinary fluoride level; compare with work category 1, P<0.01 by ANOVA; compare with work category 2, P<0.01 by ANOVA BF and UF levels of aluminum electrolytic and aluminum pole workshop workers were significantly higher (P<0.01), which were due to higher level of AF in the workshop. Since the large-scale use of cryolite, which is rich in F and could emit a lot of F into the air (4), the levels of AF in the aluminum electrolytic and aluminum pole workshop were significantly higher than the office area, (P<0.01). As the AF level increased, the BF and UF levels increased too. Related studies have shown that F bone injury is mainly caused by high F burden (5), so reduce the AF of the workplace contribute to the prevention of F bone injury. Meanwhile enhancing the operations of the personal protection of workers, workshop monitoring and occupational health care of the workers are still necessary. To sum up, our study found that due to AF, the work category could affect the F burden indirectly. Some appropriate measures were presented to reduce AF and prevent F bone injury. However, the relevant factors of F burden in our study are not comprehensive enough, and thus, our survey need further in-depth study.
  4 in total

1.  [Survey of morbidity of industrial fluorosis in workers exposed to electrolytic aluminum].

Authors:  Sheng-jun Zhang
Journal:  Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi       Date:  2007-02

2.  Incidence of skeletal deformities in endemic fluorosis.

Authors:  Shashi A; Kumar M; Bhardwaj M
Journal:  Trop Doct       Date:  2008-10       Impact factor: 0.731

3.  Rapid method for the determination of trace fluoride and activation of ion-selective electrode.

Authors:  Sheng-xun Shi; Zhi-guang Zhu; Ran Suo; Chun Wang
Journal:  Anal Sci       Date:  2003-05       Impact factor: 2.081

4.  An initial-rate potentiometric method for the determination of uric acid using a fluoride ion-selective electrode.

Authors:  Farzad Deyhimi; Rahman Salamat-Ahangari
Journal:  Talanta       Date:  2003-11-12       Impact factor: 6.057

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.