Literature DB >> 18963275

Sample contamination as a source of error in trace-element analysis of biological samples.

J Versieck1, F Barbier, R Cornelis, J Hoste.   

Abstract

Trace-element levels estimated by different investigators are often disparate. It is becoming increasingly evident that sample contamination may explain some of the discrepancies. A method has been developed for the direct estimation of potential errors. This shows that extraneous additions occurring during sample collection and preparation may give rise to grossly misleading results on subsequent analysis.

Year:  1982        PMID: 18963275     DOI: 10.1016/0039-9140(82)80238-5

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  8 in total

1.  Systemic titanium levels in rabbits with a titanium implant in the absence of wear.

Authors:  P D Bianco; P Ducheyne; J M Cuckler
Journal:  J Mater Sci Mater Med       Date:  1997-09       Impact factor: 3.896

2.  Accuracy of biological trace-element determinations.

Authors:  J Versieck; L Vanballenberghe; A De Kesel; D Van Renterghem
Journal:  Biol Trace Elem Res       Date:  1987-04       Impact factor: 3.738

3.  Urinary and blood manganese in occupationally nonexposed populations and in manual metal arc welders of mild steel.

Authors:  J Järvisalo; M Olkinuora; M Kiilunen; H Kivistö; P Ristola; A Tossavainen; A Aitio
Journal:  Int Arch Occup Environ Health       Date:  1992       Impact factor: 3.015

Review 4.  Considerations for measuring iron in post-mortem tissue of Parkinson's disease patients.

Authors:  Dominic J Hare; Manfred Gerlach; Peter Riederer
Journal:  J Neural Transm (Vienna)       Date:  2012-09-13       Impact factor: 3.575

5.  Technical Considerations for Sampling and Sample Preparation of Biomedical Samples for Trace Element Analysis.

Authors:  Robert M Parr
Journal:  J Res Natl Bur Stand (1977)       Date:  1986 Mar-Apr

6.  The Collection and Preparation of Human Blood Plasma or Serum for Trace Element Analysis.

Authors:  J Versieck
Journal:  J Res Natl Bur Stand (1977)       Date:  1986 Mar-Apr

Review 7.  Neutron activation analysis for the determination of trace elements in biological materials.

Authors:  J Versieck
Journal:  Biol Trace Elem Res       Date:  1994       Impact factor: 3.738

8.  Importance of Preanalytical Factors in Measuring Cr and Co Levels in Human Whole Blood: Contamination Control, Proper Sample Collection and Long-Term Storage Stability.

Authors:  Yuliya L Sommer; Cynthia D Ward; Joaudimir Castro Georgi; Po-Yung Cheng; Robert L Jones
Journal:  J Anal Toxicol       Date:  2021-03-12       Impact factor: 3.367

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.