Literature DB >> 18956180

Clinical and biological assessment of cemented titanium femoral stems: an 11-year experience.

Patrick Boyer1, Jean-Yves Lazennec, Joel Poupon, Marc-Antoine Rousseau, Philippe Ravaud, Yves Catonné.   

Abstract

This study prospectively assessed the outcome of 134 cemented titanium stems and serum ion levels. The stems were polished (0.1 microm Ra) with circular cross section. At the end point, only one stem revision was performed for aseptic loosening, and two were planned due to subsidence greater than 5 mm. Non-progressive radiolucencies in zones 1 and 7 were observed in 16 hips at the cement-bone interface without osteolysis. Median serum titanium concentrations were below the detection limit (30 nmol/l) except in patients with failed stems. The overall stem survival rate was 97.7% at nine years, which is comparable to other series of cemented stems. The protective layer of titanium oxide coating the stem and a thick cement mantle may help resist aseptic loosening. In addition, satisfactory monitoring of the stem was reached using titanium serum level determination.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18956180      PMCID: PMC2899120          DOI: 10.1007/s00264-008-0678-9

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  26 in total

1.  Serum titanium level for diagnosis of a failed, metal-backed patellar component.

Authors:  S S Leopold; R A Berger; L Patterson; A K Skipor; R M Urban; J J Jacobs
Journal:  J Arthroplasty       Date:  2000-10       Impact factor: 4.757

2.  Osteolysis in cemented titanium alloy hip prosthesis.

Authors:  E Schöll; S Eggli; R Ganz
Journal:  J Arthroplasty       Date:  2000-08       Impact factor: 4.757

Review 3.  Potential of coatings in total hip replacement.

Authors:  Reijo Lappalainen; Seppo S Santavirta
Journal:  Clin Orthop Relat Res       Date:  2005-01       Impact factor: 4.176

4.  Factors affecting cement strains near the tip of a cemented femoral component.

Authors:  D M Estok; T E Orr; W H Harris
Journal:  J Arthroplasty       Date:  1997-01       Impact factor: 4.757

Review 5.  Osteolysis and particle disease in hip replacement. A review.

Authors:  W H Harris
Journal:  Acta Orthop Scand       Date:  1994-02

Review 6.  Early failure of modern cemented stems.

Authors:  R L Barrack
Journal:  J Arthroplasty       Date:  2000-12       Impact factor: 4.757

Review 7.  Can metal levels be used to monitor metal-on-metal hip arthroplasties?

Authors:  Joshua J Jacobs; Anastasia K Skipor; Patricia A Campbell; Nadim J Hallab; Robert M Urban; Harlan C Amstutz
Journal:  J Arthroplasty       Date:  2004-12       Impact factor: 4.757

8.  Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study.

Authors:  J J Jacobs; A K Skipor; L M Patterson; N J Hallab; W G Paprosky; J Black; J O Galante
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

9.  [10-year actuarial analysis of a cohort of 156 total hip prostheses of a cemented polished aluminum/polyethylene alloy].

Authors:  S Le Mouel; J Allain; D Goutallier
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1998-07

Review 10.  Titanium as the material of choice for cementless femoral components in total hip arthroplasty.

Authors:  W C Head; D J Bauk; R H Emerson
Journal:  Clin Orthop Relat Res       Date:  1995-02       Impact factor: 4.176

View more
  3 in total

1.  Coordinating retrieval and register studies improves postmarket surveillance.

Authors:  Peter Ellison; Geir Hallan; Paul Johan Høl; Nils Roar Gjerdet; Leif I Havelin
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  Secondary cement injection technique reduces pulmonary embolism in total hip arthroplasty.

Authors:  Florian Schmidutz; Tobias Düll; Ole Voges; Thomas Grupp; Peter Müller; Volkmar Jansson
Journal:  Int Orthop       Date:  2012-04-15       Impact factor: 3.075

3.  Outcome and serum ion determination up to 11 years after implantation of a cemented metal-on-metal hip prosthesis.

Authors:  Jean-Yves Lazennec; Patrick Boyer; Joel Poupon; Marc-Antoine Rousseau; Carine Roy; Philippe Ravaud; Yves Catonné
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.