Literature DB >> 18950930

Acoustic and kinetic behaviour of definity in mice exposed to high frequency ultrasound.

Shawn Stapleton1, Heather Goodman, Yu-Qing Zhou, Emmanuel Cherin, R Mark Henkelman, Peter N Burns, F Stuart Foster.   

Abstract

Microbubble contrast agents have shown clinical potential for characterising blood flow using 1 to 10 MHz ultrasound; however, scaling their use for similar applications in the mouse with high frequency ultrasound (20 to 60 MHz) has not been addressed. The goal was to determine the utility of microbubbles for mouse imaging with 30 MHz ultrasound by investigating their attenuation and backscatter characteristics as a function of concentration in vitro and dose response in vivo. The agent was exposed to a 30 MHz, 20% bandwidth pulse with a peak negative pressure of 244 kPa. In vitro results showed that the attenuation and backscatter increased linearly for concentrations between 2.8 x 10(6) and 28 x 10(6) bubbles per mL of deionized water. In vivo experiments where performed in the jugular vein of CD-1 mice and time intensity curves were acquired for doses between 10 and 100 microL kg(-1). These doses corresponded to the range of concentrations used in vitro. In vivo results showed that the peak enhancement of the agent increased linearly for doses between 10 and 60 microL kg(-1), the duration of enhancement varied between 200 to 300 s and the integrated enhancement (area under the curve) increased linearly up to 100 microL kg(-1). A maximum enhancement of 13 dB over the blood pool was observed for a dose of 100 microL kg(-1). The intra- and inter-mouse variabilities were 10% to 40% and indicate that further optimisations are required. These results suggest that quantitative contrast flow studies in the mouse using high frequency ultrasound are possible for doses between 10 and 60 microL kg(-1).

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18950930     DOI: 10.1016/j.ultrasmedbio.2008.08.010

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  10 in total

1.  On the Relationship between Dynamic Contrast-Enhanced Ultrasound Parameters and the Underlying Vascular Architecture Extracted from Acoustic Angiography.

Authors:  Anastasiia Panfilova; Sarah E Shelton; Cristina Caresio; Ruud J G van Sloun; Filippo Molinari; Hessel Wijkstra; Paul A Dayton; Massimo Mischi
Journal:  Ultrasound Med Biol       Date:  2018-11-30       Impact factor: 2.998

2.  Estimating concentration of ultrasound contrast agents with backscatter coefficients: experimental and theoretical aspects.

Authors:  Scott M Leithem; Roberto J Lavarello; William D O'Brien; Michael L Oelze
Journal:  J Acoust Soc Am       Date:  2012-03       Impact factor: 1.840

3.  Effect of microbubble size on fundamental mode high frequency ultrasound imaging in mice.

Authors:  Shashank Sirsi; Jameel Feshitan; James Kwan; Shunichi Homma; Mark Borden
Journal:  Ultrasound Med Biol       Date:  2010-05-05       Impact factor: 2.998

4.  High-Frequency Multipulse, Plane-Wave Acoustic Contrast Imaging.

Authors:  Jeffrey A Ketterling; Ronald H Silverman
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-12-16       Impact factor: 2.725

5.  Dependence of the reversibility of focused- ultrasound-induced blood-brain barrier opening on pressure and pulse length in vivo.

Authors:  Gesthimani Samiotaki; Elisa E Konofagou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-11       Impact factor: 2.725

6.  Broadband attenuation measurements of phospholipid-shelled ultrasound contrast agents.

Authors:  Jason L Raymond; Kevin J Haworth; Kenneth B Bader; Kirthi Radhakrishnan; Joseph K Griffin; Shao-Ling Huang; David D McPherson; Christy K Holland
Journal:  Ultrasound Med Biol       Date:  2013-11-19       Impact factor: 2.998

7.  Reproducibility of Contrast-Enhanced Ultrasound in Mice with Controlled Injection.

Authors:  Alexandre Dizeux; Thomas Payen; Guillaume Barrois; Delphine Le Guillou Buffello; S Lori Bridal
Journal:  Mol Imaging Biol       Date:  2016-10       Impact factor: 3.488

8.  The effect of inhaled gases on ultrasound contrast agent longevity in vivo.

Authors:  Malak Itani; Robert F Mattrey
Journal:  Mol Imaging Biol       Date:  2012-02       Impact factor: 3.488

9.  Circulating Magnetic Microbubbles for Localized Real-Time Control of Drug Delivery by Ultrasonography-Guided Magnetic Targeting and Ultrasound.

Authors:  Beata Chertok; Robert Langer
Journal:  Theranostics       Date:  2018-01-01       Impact factor: 11.556

10.  In vitro acoustic characterization of three phospholipid ultrasound contrast agents from 12 to 43 MHz.

Authors:  Chao Sun; Vassilis Sboros; Mairead B Butler; Carmel M Moran
Journal:  Ultrasound Med Biol       Date:  2013-12-19       Impact factor: 2.998

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.