Literature DB >> 1894868

Patterns in visual interpretation of coronary arteriograms as detected by quantitative coronary arteriography.

R M Fleming1, R L Kirkeeide, R W Smalling, K L Gould.   

Abstract

In part 1 of a three-part study, 14 novice readers and 6 experienced cardiologists interpreted phantom images of known stenosis severity. No difference between the interpretations of experienced and novice readers was detectable. Visual estimates of "moderately" severe stenosis were 30% higher than actual percent diameter stenosis. In part 2 of the study, visual interpretation of percent diameter stenosis from 212 stenoses on 241 arteriograms was compared with quantitative coronary arteriographic assessment. The visual analysis overestimated disease severity in arteries with greater than or equal to 50% diameter stenosis (except for right coronary lesions) and underestimated severity in all arteries with less than 50% diameter stenosis. Of the 241 arteriograms, 40 had quantitative and visual analysis of all three coronary arteries for assessment of significant disease. In only 62% of the cases did visual and quantitative methods agree on the presence of severe disease; visual estimates diagnosed significantly (p less than 0.05) more three-vessel disease. In part 3 of the study, comparison of percent diameter stenosis by visual estimate with quantitative coronary arteriographic assessment before and after balloon angioplasty of 38 stenoses showed that visual interpretation significantly (p less than 0.001) overestimated initial lesion severity and underestimated stenosis severity after angioplasty.

Entities:  

Mesh:

Year:  1991        PMID: 1894868     DOI: 10.1016/0735-1097(91)90752-u

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  25 in total

1.  Adaptive edge localisation approach for quantitative coronary analysis.

Authors:  A S Al-Fahoum
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602

2.  Restenosis after coronary angioplasty: a proposal of new comparative approaches based on quantitative angiography.

Authors:  P W Serruys; D P Foley; P J de Feyter
Journal:  Br Heart J       Date:  1992-10

3.  Lossy JPEG compression in quantitative angiography: the role of X-ray quantum noise.

Authors:  Johannes Peter Fritsch; Rüdiger Brennecke
Journal:  J Digit Imaging       Date:  2011-06       Impact factor: 4.056

4.  The absence of coronary calcification does not exclude obstructive coronary artery disease or the need for revascularization in patients referred for conventional coronary angiography.

Authors:  Ilan Gottlieb; Julie M Miller; Armin Arbab-Zadeh; Marc Dewey; Melvin E Clouse; Leonardo Sara; Hiroyuki Niinuma; David E Bush; Narinder Paul; Andrea L Vavere; John Texter; Jeffery Brinker; João A C Lima; Carlos E Rochitte
Journal:  J Am Coll Cardiol       Date:  2010-02-16       Impact factor: 24.094

Review 5.  Novel QCA methodologies and angiographic scores.

Authors:  Vivian G Ng; Alexandra J Lansky
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-20       Impact factor: 2.357

6.  An analogue laser optical disc in comparison with cinefilm for visual analysis of coronary narrowings before and after coronary angioplasty.

Authors:  S A Chamuleau; J J Piek; W B Hanekamp; Y E Appelman; K T Koch; R J Peters; W E Kok; G Bloemhard; G A la Rivière; G K David
Journal:  Int J Card Imaging       Date:  1998-02

Review 7.  MR first pass imaging: quantitative assessment of transmural perfusion and collateral flow.

Authors:  M Jerosch-Herold; N Wilke
Journal:  Int J Card Imaging       Date:  1997-06

8.  Impact of two formulas to calculate percentage diameter stenosis of coronary lesions: from stenosis models (phantom lesion model) to actual clinical lesions.

Authors:  Alexandre Hideo-Kajita; Samuel Wopperer; Solomon S Beyene; Yael F Meirovich; Gebremedhin D Melaku; Kayode O Kuku; Echo J Brathwaite; Yuichi Ozaki; Kazuhiro Dan; Rebecca Torguson; Ron Waksman; Hector M Garcia-Garcia
Journal:  Int J Cardiovasc Imaging       Date:  2019-07-27       Impact factor: 2.357

9.  Coronary CT angiography using 64 detector rows: methods and design of the multi-centre trial CORE-64.

Authors:  Julie M Miller; Marc Dewey; Andrea L Vavere; Carlos E Rochitte; Hiroyuki Niinuma; Armin Arbab-Zadeh; Narinder Paul; John Hoe; Albert de Roos; Kunihiro Yoshioka; Pedro A Lemos; David E Bush; Albert C Lardo; John Texter; Jeffery Brinker; Christopher Cox; Melvin E Clouse; João A C Lima
Journal:  Eur Radiol       Date:  2008-11-08       Impact factor: 5.315

Review 10.  Coronary computed tomographic angiography (CCTA) in community hospitals: "current and emerging role".

Authors:  Rakesh K Sharma; Donald J Voelker; Rajiv K Sharma; Vibhuti N Singh; Girish Bhatt; Mathilde Moazazi; Teresa Nash; Hanumanth K Reddy
Journal:  Vasc Health Risk Manag       Date:  2010-05-25
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.