Abstract

A report is presented on experience with the use of 54 plates, without primary bone grafts, after resections for malignant tumours involving the continuity of the mandible, in 52 patients. There were complications in 27 cases: postoperative infection or soft tissue dehiscence occurred 20 times, chronic soft tissue perforation once, screw loosening twice, and plate fracture four times. Adjuvant radiotherapy and/or chemotherapy had no effect on the incidence of the complications. Seventeen of the plates (a good 30%) had to be removed prematurely due to the complications. Major deformity did not always occur if relative stabilization had developed through cicatrix formation. Thirty-seven plates (barely 70%) remained: in 19 cases until the death of the patient, in 3 cases until recurrence, in 12 cases until bone grafting, and in 3 cases they were still in situ up to 65 months. In principle, reconstruction plates have proven themselves. However, application and soft tissue coverage need great care and a great deal of experience.

Entities:  

Mesh:

Year:  1991        PMID: 1894736     DOI: 10.1016/s1010-5182(05)80546-3

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  8 in total

1.  Reconstruction of osteomyelitis defects of the craniofacial skeleton.

Authors:  Gary E Decesare; Frederic W-B Deleyiannis; Joseph E Losee
Journal:  Semin Plast Surg       Date:  2009-05       Impact factor: 2.314

2.  [Computer assisted chewing power in patients with segmental resection of the mandible].

Authors:  P Maurer; H Pistner; J Schubert
Journal:  Mund Kiefer Gesichtschir       Date:  2006-01

3.  Salvage Secondary Reconstruction of the Mandible with Vascularized Fibula Flap.

Authors:  Dinesh Kadam
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2019-03-29

4.  Biomechanical In Vitro Study on the Stability of Patient-Specific CAD/CAM Mandibular Reconstruction Plates: A Comparison Between Selective Laser Melted, Milled, and Hand-Bent Plates.

Authors:  Robin Kasper; Karsten Winter; Sebastian Pietzka; Alexander Schramm; Frank Wilde
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2020-08-28

Review 5.  Hardware Removal in Craniomaxillofacial Trauma: A Systematic Review of the Literature and Management Algorithm.

Authors:  Thomas J Cahill; Rikesh Gandhi; Alexander C Allori; Jeffrey R Marcus; David Powers; Detlev Erdmann; Scott T Hollenbeck; Howard Levinson
Journal:  Ann Plast Surg       Date:  2015-11       Impact factor: 1.539

6.  The Epidemiology, treatment, and complication of ameloblastoma in East-Indonesia: 6 years retrospective study.

Authors:  M Ruslin; F-N Hendra; A Vojdani; D Hardjosantoso; M Gazali; A Tajrin; J Wolff; T Forouzanfar
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2018-01-01

7.  The Value of Three-Dimensional Modeling on Repositioning and Soft Tissue Filling in Microsurgical Reconstruction of Secondary Mandibular Defects: A Retrospective Study.

Authors:  Ioannis Tilaveridis; Glykeria Pantazi; Gregory Venetis; Konstantinos Ditsios; Christos Angelopoulos; Konstantinos Antoniades
Journal:  Cureus       Date:  2022-02-17

Review 8.  Patient-specific finite element models of the human mandible: Lack of consensus on current set-ups.

Authors:  Bram Barteld Jan Merema; Joep Kraeima; Haye H Glas; Fred K L Spijkervet; Max J H Witjes
Journal:  Oral Dis       Date:  2020-07-09       Impact factor: 3.511