Measuring energy response for RTQA radiochromic film to improve quality assurance procedures.

M J Butson1, T Cheung, P K N Yu.   

Abstract

RTQA Gafchromic, radiochromic film is assessed for its radiation energy dependence in photon beams ranging from superficial to megavoltage energies. RTQA radiochromic film has uses in radiation quality assurance procedures due to its auto development and visualisation properties. These properties allow for immediate comparison of x-ray alignment and coincidence not available with radiographic films. Results show that the RTQA film produces an energy dependant darkening to x-rays which results in x-ray energies of 69 keV photon equivalent (150 kVp) to produce 2.14 times the optical density to dose ratio of a 6MV x-ray beam. The following dose ratio's (normalized to 1 at 150 kVp) provide the same net optical density change for RTQA film. 1.47-50 kVp : 1.21-75 kVp : 1.09-100 kVp : 1.01-125 kVp: 1.00-150 kVp : 1.03-200 kVp : 1.07-250 kVp : 2.14-6 MVp : 2.14 10 MVp. Although the film is not designed to be used as a quantitative measure of radiation it is still useful to know its energy response at differing x-ray energies to expose the film to the appropriate dose to provide optimal darkening characteristics for a given QA test at the appropriate energy. Our results have shown that a 0.3 optical density change with RTQA film provides a colour change level useable for accurate alignment procedures

Entities:  

Mesh:

Year:  2008        PMID: 18946978     DOI: 10.1007/bf03179345

Source DB:  PubMed          Journal:  Australas Phys Eng Sci Med        ISSN: 0158-9938            Impact factor:   1.430


  3 in total

1.  Acceptance, commissioning and clinical use of the WOmed T-200 kilovoltage X-ray therapy unit.

Authors:  Maria M Aspradakis; Paolo Zucchetti
Journal:  Br J Radiol       Date:  2015-07-30       Impact factor: 3.039

2.  Wax boluses and accuracy of EBT and RTQA radiochromic film detectors in radiotherapy with the JINR Phasotron proton beam.

Authors:  Dorota Maria Borowicz; Julian Malicki; Gennady Mytsin; Konstantin Shipulin
Journal:  Rep Pract Oncol Radiother       Date:  2013-07-02

3.  Monte Carlo-based investigation of absorbed-dose energy dependence of radiochromic films in high energy brachytherapy dosimetry.

Authors:  Mishra Subhalaxmi; T Palani Selvam
Journal:  J Appl Clin Med Phys       Date:  2014-01-06       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.