Literature DB >> 18945620

Improved intra-operative reduction control using a three-dimensional mobile image intensifier - a proximal tibia cadaver study.

T Gösling1, K Klingler, J Geerling, H Shin, M Fehr, C Krettek, T Hüfner.   

Abstract

This study aimed to analyse whether the precision of a three-dimensional mobile image intensifier (ISO-C 3D) differs from conventional two-dimensional fluoroscopy and high resolution CT scan in a fracture model of the proximal tibia. A depression fracture of the medial plateau (AO/OTA 41-B2.3) was created in 12 formalin-fixed, human cadaver knees. The cartilage of the depression could be positioned above (+1mm, +2mm), below (-1mm, -2mm), or in line with the joint surface. Fluoroscopy, computed tomography (CT) scans, and ISO-C 3D scans (four different protocols: 100 images, 66 images, 50 images, and 33 images) were done for each fracture level. Three independent observers assessed each imaging set. The difference between the estimated reduction and the real reduction was used for statistical analysis. Our hypothesis was that no differences in the precision exist between the imaging techniques (p<0.05). The conventional image intensifier group (0.7 mm+/-0.67) showed significantly higher deviations than the CT group (0.3 mm+/-0.43; p<0.001) and significantly higher deviations than all ISO-C 3D groups (0.4-0.5 mm; p<0.001). Of the ISO-C 3D groups, only the scan protocol with the lowest number of images (0.5 mm+/-0.51) showed significantly lower precision than the CT group (p<0.001). It was concluded that the three-dimensional mobile image intensifier showed higher precision in reduction assessment in a fracture model of the tibial plateau compared to fluoroscopy. High resolution CT scans should remain the standard for post-operative assessment of reduction outside the operating theatre.

Entities:  

Mesh:

Year:  2008        PMID: 18945620     DOI: 10.1016/j.knee.2008.07.012

Source DB:  PubMed          Journal:  Knee        ISSN: 0968-0160            Impact factor:   2.199


  8 in total

1.  Three-column classification and Schatzker classification: a three- and two-dimensional computed tomography characterisation and analysis of tibial plateau fractures.

Authors:  Sheethal Prasad Patange Subba Rao; James Lewis; Ziad Haddad; Vishal Paringe; Khitish Mohanty
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-09-08

Review 2.  [Intraoperative 3D imaging : Diagnostic accuracy and therapeutic benefits].

Authors:  D Stengel; M Wich; A Ekkernkamp; N Spranger
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

Review 3.  [3D safety in osteosynthesis adjacent to joints].

Authors:  J Franke; S Y Vetter; N Beisemann; B Swartman; P A Grützner; M Schnetzke
Journal:  Unfallchirurg       Date:  2016-10       Impact factor: 1.000

4.  Assessment of two 3-D fluoroscopic systems for articular fracture reduction: a cadaver study.

Authors:  Yoram A Weil; Meir Liebergall; Rami Mosheiff; Syndie B Singer; Leo Joskowicz; Amal Khoury
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-02-06       Impact factor: 2.924

5.  Intraoperative 3D imaging in the treatment of elbow fractures--a retrospective analysis of indications, intraoperative revision rates, and implications in 36 cases.

Authors:  Marc Schnetzke; Julia Fuchs; Sven Y Vetter; Nils Beisemann; Holger Keil; Paul-Alfred Grützner; Jochen Franke
Journal:  BMC Med Imaging       Date:  2016-03-18       Impact factor: 1.930

6.  Intraoperative 3D imaging in intraarticular tibial plateau fractures - Does it help to improve the patients' outcomes?

Authors:  F Souleiman; R Henkelmann; U Spiegl; P Hepp; J Theopold; J Fakler
Journal:  J Orthop Surg Res       Date:  2021-05-05       Impact factor: 2.359

7.  The morphological features of different Schatzker types of tibial plateau fractures: a three-dimensional computed tomography study.

Authors:  Pengbo Chen; Hao Shen; Wei Wang; Binbin Ni; Zhiyuan Fan; Hua Lu
Journal:  J Orthop Surg Res       Date:  2016-08-27       Impact factor: 2.359

8.  Comparison between three-dimensional CT and conventional radiography in proximal tibia morphology.

Authors:  Yijie Zhang; Yanxi Chen; Minfei Qiang; Kun Zhang; Haobo Li; Yuchen Jiang; Xiaoyang Jia
Journal:  Medicine (Baltimore)       Date:  2018-07       Impact factor: 1.889

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.