Literature DB >> 24013813

Three-column classification and Schatzker classification: a three- and two-dimensional computed tomography characterisation and analysis of tibial plateau fractures.

Sheethal Prasad Patange Subba Rao1, James Lewis, Ziad Haddad, Vishal Paringe, Khitish Mohanty.   

Abstract

OBJECTIVE: The aim of the study was to evaluate inter-observer reliability and intra-observer reproducibility between the three-column classification and Schatzker classification systems using 2D and 3D CT models.
MATERIALS AND METHODS: Fifty-two consecutive patients with tibial plateau fractures were evaluated by five orthopaedic surgeons. All patients were classified into Schatzker and three-column classification systems using x-rays and 2D and 3D CT images. The inter-observer reliability was evaluated in the first round and the intra-observer reliability was determined during the second round 2 weeks later.
RESULTS: The average intra-observer reproducibility for the three-column classification was from substantial to excellent in all sub classifications, as compared with Schatzker classification. The inter-observer kappa values increased from substantial to excellent in three-column classification and to moderate in Schatzker classification The average values for three-column classification for all the categories are as follows: (I-III) k2D = 0.718, 95% CI 0.554-0.864, p < 0.0001 and average 3D = 0.874, 95% CI 0.754-0.890, p < 0.0001. For Schatzker classification system, the average values for all six categories are as follows: (I-VI) k2D = 0.536, 95% CI 0.365-0.685, p < 0.0001 and average k3D = 0.552 95% CI 0.405-0.700, p < 0.0001. The values are statistically significant.
CONCLUSION: Statistically significant inter-observer values in both rounds were noted with the three-column classification, making it statistically an excellent agreement. The intra-observer reproducibility for the three-column classification improved as compared with the Schatzker classification. The three-column classification seems to be an effective way to characterise and classify fractures of tibial plateau.

Entities:  

Mesh:

Year:  2013        PMID: 24013813     DOI: 10.1007/s00590-013-1308-9

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  31 in total

1.  Interobserver and intraobserver variation in classification systems for fractures of the distal humerus.

Authors:  A M Wainwright; J R Williams; A J Carr
Journal:  J Bone Joint Surg Br       Date:  2000-07

2.  AO or Schatzker? How reliable is classification of tibial plateau fractures?

Authors:  N P Walton; S Harish; C Roberts; C Blundell
Journal:  Arch Orthop Trauma Surg       Date:  2003-08-12       Impact factor: 3.067

3.  Bicondylar tibial plateau fractures managed with the Sheffield Hybrid Fixator. Biomechanical study and operative technique.

Authors:  A M Ali; L Yang; M Hashmi; M Saleh
Journal:  Injury       Date:  2001-12       Impact factor: 2.586

4.  Interobserver reliability and intraobserver reproducibility of the modified Ficat classification system of osteonecrosis of the femoral head.

Authors:  S W Smith; R A Meyer; P M Connor; S E Smith; E N Hanley
Journal:  J Bone Joint Surg Am       Date:  1996-11       Impact factor: 5.284

5.  [Preoperative computerized tomography diagnosis of fractures of the tibial plateau].

Authors:  W Hackl; J Riedl; M Reichkendler; K P Benedetto; M Freund; R Bale
Journal:  Unfallchirurg       Date:  2001-06       Impact factor: 1.000

6.  Estimation of pretraumatic femoral antetorsion in bilateral femoral shaft fractures.

Authors:  Musa Citak; Mustafa Citak; Daniel Kendoff; Padhraig F O'Loughlin; Frank Tavassol; Michael Jagodzinski; Christian Krettek; Tobias Hüfner
Journal:  Skeletal Radiol       Date:  2009-07-17       Impact factor: 2.199

Review 7.  High-energy fractures of the tibial plateau.

Authors:  J T Watson
Journal:  Orthop Clin North Am       Date:  1994-10       Impact factor: 2.472

8.  Evaluation of tibial plateau fractures: efficacy of MR imaging compared with CT.

Authors:  L Kode; J M Lieberman; A O Motta; J H Wilber; A Vasen; R Yagan
Journal:  AJR Am J Roentgenol       Date:  1994-07       Impact factor: 3.959

9.  Improved intra-operative reduction control using a three-dimensional mobile image intensifier - a proximal tibia cadaver study.

Authors:  T Gösling; K Klingler; J Geerling; H Shin; M Fehr; C Krettek; T Hüfner
Journal:  Knee       Date:  2008-10-21       Impact factor: 2.199

Review 10.  Tibial plateau fractures. Management and expected results.

Authors:  H Tscherne; P Lobenhoffer
Journal:  Clin Orthop Relat Res       Date:  1993-07       Impact factor: 4.176

View more
  6 in total

1.  Are there four tibia plateau columns?

Authors:  Harm Hoekstra
Journal:  Int Orthop       Date:  2017-08-21       Impact factor: 3.075

2.  The best cited articles of the European Journal of Orthopaedic Surgery and Traumatology (EJOST): a bibliometric analysis.

Authors:  Andreas F Mavrogenis; Panayiotis D Megaloikonomos; Cyril Mauffrey; Marius M Scarlat; Patrick Simon; Kazuhiro Hasegawa; Samo K Fokter; Pierre Kehr
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-02-14

3.  Recent progress in the diagnosis and treatment of posterior tibial plateau fractures.

Authors:  Hongwei Chen; Shimin Chang; Jun Pan
Journal:  Int J Clin Exp Med       Date:  2015-04-15

4.  Importance of CT Scan in Predicting the Outcomes of Tibial Plateau Fractures: A Retrospective Study of 216 Patients over 10 Years' Time.

Authors:  Lorenzo Milani; Silvana Ferrari
Journal:  Indian J Orthop       Date:  2021-09-20       Impact factor: 1.033

5.  Reliability and repeatability of tibial plateau fracture assessment with an injury mechanism-based concept.

Authors:  B-B Zhang; H Sun; Y Zhan; Q-F He; Y Zhu; Y-K Wang; C-F Luo
Journal:  Bone Joint Res       Date:  2019-09-03       Impact factor: 5.853

6.  Three-Dimensional Reconstruction Modeling of the Spatial Displacement, Extent and Rotational Orientation of Undisplaced Femoral Neck Fractures.

Authors:  Xin Fu; Gui-Jun Xu; Zhi-Jun Li; Chang-Ling Du; Zhe Han; Tao Zhang; Xinlong Ma
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.