Literature DB >> 18931875

Patient dose reference levels for interventional radiology: a national approach.

Eliseo Vano1, R Sanchez, J M Fernandez, J J Gallego, J F Verdu, M Gonzalez de Garay, A Azpiazu, A Segarra, M T Hernandez, M Canis, F Diaz, F Moreno, J Palmero.   

Abstract

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm(2) for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm(2) for lower limb arteriography (685 cases), 89 Gy cm(2) for renal arteriography (55 cases), 80 Gy cm(2) for biliary drainage (205 cases), 289 Gy cm(2) for hepatic chemoembolization (151 cases), 94 Gy cm(2) for iliac stent (70 cases), and 236 Gy cm(2) for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

Entities:  

Mesh:

Year:  2008        PMID: 18931875     DOI: 10.1007/s00270-008-9439-9

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  13 in total

1.  Patient radiation doses and reference levels in pediatric interventional radiology.

Authors:  Bouchra Habib Geryes; Adeline Bak; Julie Lachaux; Augustin Ozanne; Nathalie Boddaert; Francis Brunelle; Olivier Naggara; Guillaume Saliou
Journal:  Eur Radiol       Date:  2017-02-16       Impact factor: 5.315

2.  Reference levels for patient radiation doses in interventional radiology: proposed initial values for U.S. practice.

Authors:  Donald L Miller; Deukwoo Kwon; Grant H Bonavia
Journal:  Radiology       Date:  2009-09-29       Impact factor: 11.105

3.  Reference air kerma and kerma-area product as estimators of peak skin dose for fluoroscopically guided interventions.

Authors:  Deukwoo Kwon; Mark P Little; Donald L Miller
Journal:  Med Phys       Date:  2011-07       Impact factor: 4.071

4.  Effective-dose estimation in interventional radiological procedures.

Authors:  Maria D Falco; Salvatore Masala; Matteo Stefanini; Paolo Bagalà; Daniele Morosetti; Eros Calabria; Alessia Tonnetti; Gianluca Verona-Rinati
Journal:  Radiol Phys Technol       Date:  2018-03-08

5.  Proposed achievable levels of dose and impact of dose-reduction systems for thrombectomy in acute ischemic stroke: an international, multicentric, retrospective study in 1096 patients.

Authors:  Adrien Guenego; Pascal J Mosimann; Vitor Mendes Pereira; Patrick Nicholson; Kevin Zuber; Jean Albert Lotterie; Tomas Dobrocky; David G Marcellus; Jean Marc Olivot; Michel Piotin; Jan Gralla; Robert Fahed; Max Wintermark; Jeremy J Heit; Christophe Cognard
Journal:  Eur Radiol       Date:  2019-03-22       Impact factor: 5.315

6.  Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

Authors:  R Ruiz-Cruces; E Vano; F Carrera-Magariño; F Moreno-Rodriguez; M M Soler-Cantos; M Canis-Lopez; J Hernández-Armas; F J Diaz-Romero; F Rosales-Espizua; J M Fernandez-Soto; R Sanchez-Casanueva; A Martin-Palanca; M Perez-Martinez; A Gil-Agudo; M A Zarca-Diaz; V Parra-Osorio; J J Muñoz Ruiz-Canela; T Moreno-Sanchez; A Lopez-Medina; C Moreno-Saiz; P Galan-Montenegro; J J Gallego-Beuter; M Gonzalez-de-Garay; J C Zapata-Jimenez; J M Pastor-Vega; S Cañete
Journal:  Eur Radiol       Date:  2016-07-06       Impact factor: 5.315

7.  Evaluation of Radiation Exposure on Physicians During Angioplasty for Hemodialysis Access Dysfunction.

Authors:  Po-Sen Huang; Zhih-Cherng Chen; Kuo-Ting Tang; Wei-Ting Chang
Journal:  Acta Cardiol Sin       Date:  2019-01       Impact factor: 2.672

8.  Evaluation of radiation dose to patients undergoing interventional radiology procedures at Ramathibodi Hospital, Thailand.

Authors:  J Urairat; S Asavaphatiboon; S Singhara Na Ayuthaya; N Pongnapang
Journal:  Biomed Imaging Interv J       Date:  2011-07-01

9.  Radiation-induced noncancer risks in interventional cardiology: optimisation of procedures and staff and patient dose reduction.

Authors:  Zhonghua Sun; Aini AbAziz; Ahmad Khairuddin Md Yusof
Journal:  Biomed Res Int       Date:  2013-08-20       Impact factor: 3.411

10.  A comparison of two peak skin dose metrics calculated by patient dose management systems: implications for clinical management.

Authors:  Alisha Coates; Andy Rogers
Journal:  Br J Radiol       Date:  2021-05-13       Impact factor: 3.039

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.