Literature DB >> 18931643

Audiologic outcomes with the penetrating electrode auditory brainstem implant.

Steven R Otto1, Robert V Shannon, Eric P Wilkinson, William E Hitselberger, Douglas B McCreery, Jean K Moore, Derald E Brackmann.   

Abstract

OBJECTIVE: The penetrating electrode auditory brainstem implant (PABI) is an extension of auditory brainstem implant (ABI) technology originally developed for individuals deafened by neurofibromatosis type 2. Whereas the conventional ABI uses surface electrodes on the cochlear nuclei, the PABI uses 8 or 10 penetrating microelectrodes in conjunction with a separate array of 10 or 12 surface electrodes. The goals of the PABI were to use microstimulation to reduce threshold current levels, increase the range of pitch percepts, and improve electrode selectivity and speech recognition. PATIENTS AND PROTOCOL: In a prospective clinical trial, 10 individuals, all with neurofibromatosis type 2, received a PABI after vestibular schwannoma removal via a translabyrinthine approach. All study participants met strict requirements for informed consent as part of a Food and Drug Administration clinical trial. Approximately 8 weeks after implantation, PABI devices were activated and tested at our tertiary clinical and research facility. Mean follow-up time was 33.8 months. STUDY
DESIGN: Using a single-subject design, we measured thresholds and dynamic ranges, electrode-specific pitch percepts, and speech perception performance at regular intervals.
RESULTS: Penetrating electrodes produced auditory thresholds at substantially lower charge levels than surface electrodes, a wide range of electrode-specific pitch sensations, and minimal cross-electrode interference and could be used in speech maps either alone or in combination with surface electrodes. However, less than 25% of penetrating electrodes resulted in auditory sensations, whereas more than 60% of surface electrodes were effective. Even after more than 3 years of experience, patients using penetrating electrodes did not achieve improved speech recognition compared with those using surface electrode ABIs. In patients with usable penetrating electrodes, City University of New York Sentence Test scores with sound and visual information were 61.6% in the PABI group and 64.7% in a surface ABI cohort (p = not significant).
CONCLUSION: The PABI met the goals of lower threshold, increased pitch range, and high selectivity, but these properties did not result in improved speech recognition.

Entities:  

Mesh:

Year:  2008        PMID: 18931643     DOI: 10.1097/MAO.0b013e31818becb4

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  19 in total

Review 1.  Auditory midbrain implant: a review.

Authors:  Hubert H Lim; Minoo Lenarz; Thomas Lenarz
Journal:  Trends Amplif       Date:  2009-09

2.  Primary auditory cortical responses to electrical stimulation of the thalamus.

Authors:  Craig A Atencio; Jonathan Y Shih; Christoph E Schreiner; Steven W Cheung
Journal:  J Neurophysiol       Date:  2013-12-11       Impact factor: 2.714

3.  Responses of neurons in the feline inferior colliculus to modulated electrical stimuli applied on and within the ventral cochlear nucleus; Implications for an advanced auditory brainstem implant.

Authors:  Douglas McCreery; Kamal Yadev; Martin Han
Journal:  Hear Res       Date:  2018-03-09       Impact factor: 3.208

4.  Options and strategies for hearing restoration in pediatric neurofibromatosis type 2.

Authors:  Hossein Mahboubi; William H Slattery; Gautam U Mehta; Gregory P Lekovic
Journal:  Childs Nerv Syst       Date:  2020-06-21       Impact factor: 1.475

5.  Robust penetrating microelectrodes for neural interfaces realized by titanium micromachining.

Authors:  Patrick T McCarthy; Kevin J Otto; Masaru P Rao
Journal:  Biomed Microdevices       Date:  2011-06       Impact factor: 2.838

Review 6.  Advances in auditory prostheses.

Authors:  Robert V Shannon
Journal:  Curr Opin Neurol       Date:  2012-02       Impact factor: 5.710

Review 7.  Auditory implant research at the House Ear Institute 1989-2013.

Authors:  Robert V Shannon
Journal:  Hear Res       Date:  2014-11-17       Impact factor: 3.208

8.  In vivo validation of custom-designed silicon-based microelectrode arrays for long-term neural recording and stimulation.

Authors:  Martin Han; Panya S Manoonkitiwongsa; Cindy X Wang; Douglas B McCreery
Journal:  IEEE Trans Biomed Eng       Date:  2011-10-18       Impact factor: 4.538

9.  Conducting polymer electrodes for auditory brainstem implants.

Authors:  Amélie A Guex; Nicolas Vachicouras; Ariel E Hight; M Christian Brown; Daniel J Lee; Stéphanie P Lacour
Journal:  J Mater Chem B       Date:  2015       Impact factor: 6.331

Review 10.  Beyond cochlear implants: awakening the deafened brain.

Authors:  David R Moore; Robert V Shannon
Journal:  Nat Neurosci       Date:  2009-05-26       Impact factor: 24.884

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.