Responses of neurons in the feline inferior colliculus to modulated electrical stimuli applied on and within the ventral cochlear nucleus; Implications for an advanced auditory brainstem implant.

Douglas McCreery1, Kamal Yadev2, Martin Han3.   

Abstract

Auditory brainstem implants (ABIs) can restore useful hearing to persons with deafness who cannot benefit from cochlear implants. However, the quality of hearing restored by ABIs rarely is comparable to that provided by cochlear implants in persons for whom those are appropriate. In an animal model, we evaluated elements of a prototype of an ABI in which the functions of macroelectrodes on the surface of the dorsal cochlear nucleus would be integrated with the function of multiple penetrating microelectrodes implanted into the ventral cochlear nucleus. The surface electrodes would convey most of the range of loudness percepts while the intranuclear microelectrodes would sharpen and focus pitch percepts. In the present study, stimulating electrodes were implanted chronically on the surface of the animal's dorsal cochlear nucleus (DCN) and also within their ventral cochlear nucleus (VCN). Recording microelectrodes were implanted into the central nucleus of the inferior colliculus (ICC). The electrical stimuli were sinusoidally modulated stimulus pulse trains applied on the DCN and within the VCN. Temporal encoding of neuronal responses was quantified as vector strength (VS) and as full-cycle rate of neuronal activity in the ICC. VS and full-cycle AP rate were measured for 4 stimulation modes; continuous and transient amplitude modulation of the stimulus pulse trains, each delivered via the macroelectrode on the surface of the DCN and then by the intranuclear penetrating microelectrodes. In the proposed clinical device the functions of the surface and intranuclear microelectrodes could best be integrated if there is minimal variation in the neuronal responses across the range of modulation depth, modulation frequencies, and across the four stimulation modes. In this study VS did vary as much as 34% across modulation frequency and modulation depth within a stimulation mode, and up to 40% between modulation modes. However, these intra- and inter-mode variances differed for different stimulation rates, and at 500 Hz the inter-mode differences in VS and across the range of modulation frequencies and modulation depths was<Roman> = </Roman>24% and the intra-modal differences were<Roman> = </Roman>15%. The findings were generally similar for rate encoding of modulation depth, although the depth of transient amplitude modulation delivered by the surface electrode was weakly encoded as full-cycle rate. Overall, our findings support the concept of a clinical ABI that employs surface stimulation and intranuclear microstimulation in an integrated manner.
Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Auditory brainstem implants; Cochlear nucleus; Inferior colliculus; Microelectrodes; Neuronal coding of modulation

Mesh:

Year:  2018        PMID: 29573880      PMCID: PMC5940528          DOI: 10.1016/j.heares.2018.03.009

Source DB:  PubMed          Journal:  Hear Res        ISSN: 0378-5955            Impact factor:   3.208


  70 in total

1.  Twenty-year report of the first auditory brain stem nucleus implant.

Authors:  W F House; W E Hitselberger
Journal:  Ann Otol Rhinol Laryngol       Date:  2001-02       Impact factor: 1.547

2.  Loudness balance between electric and acoustic stimulation.

Authors:  F G Zeng; R V Shannon
Journal:  Hear Res       Date:  1992-07       Impact factor: 3.208

3.  The representation of amplitude modulations in the mammalian auditory midbrain.

Authors:  Bjarne Krebs; Nicholas A Lesica; Benedikt Grothe
Journal:  J Neurophysiol       Date:  2008-07-09       Impact factor: 2.714

4.  Hearing by cochlear nucleus stimulation in humans.

Authors:  B J Edgerton; W F House; W Hitselberger
Journal:  Ann Otol Rhinol Laryngol Suppl       Date:  1982 Mar-Apr

5.  Chronic microstimulation in the feline ventral cochlear nucleus: physiologic and histologic effects.

Authors:  D B McCreery; T G Yuen; L A Bullara
Journal:  Hear Res       Date:  2000-11       Impact factor: 3.208

6.  Update on long-term results with auditory brainstem implants in NF2 patients.

Authors:  Sangeeta Maini; Mauricio A Cohen; Rod Hollow; Robert Briggs
Journal:  Cochlear Implants Int       Date:  2009

Review 7.  Auditory brainstem implants.

Authors:  Marc S Schwartz; Steven R Otto; Robert V Shannon; William E Hitselberger; Derald E Brackmann
Journal:  Neurotherapeutics       Date:  2008-01       Impact factor: 7.620

8.  The human auditory brain stem: a comparative view.

Authors:  J K Moore
Journal:  Hear Res       Date:  1987       Impact factor: 3.208

9.  Direct electrical stimulation of the cochlear nucleus: surface vs. penetrating stimulation.

Authors:  H K el-Kashlan; J K Niparko; R A Altschuler; J M Miller
Journal:  Otolaryngol Head Neck Surg       Date:  1991-10       Impact factor: 3.497

10.  Auditory brainstem implant part II: subjective assessment of functional outcome.

Authors:  Minoo Lenarz; Cordula Matthies; Anke Lesinski-Schiedat; Carolin Frohne; Urte Rost; Angelika Illg; Rolf D Battmer; Madjid Samii; Thomas Lenarz
Journal:  Otol Neurotol       Date:  2002-09       Impact factor: 2.311

View more
  9 in total

1.  Maximizing Charge Injection Limits of Iridium Oxide Electrodes with a Programmable Anodic Bias Circuit.

Authors:  Alpaslan Ersöz; Insoo Kim; Martin Han
Journal:  Int IEEE EMBS Conf Neural Eng       Date:  2021-06-02

2.  A Diagnostic Circuit for Crosstalk Detection in Microelectrode Arrays.

Authors:  Morgan McNamara; Alpaslan Ersöz; Martin Han
Journal:  Int IEEE EMBS Conf Neural Eng       Date:  2021-06-02

3.  Comparison of Responses to DCN vs. VCN Stimulation in a Mouse Model of the Auditory Brainstem Implant (ABI).

Authors:  Stephen McInturff; Florent-Valéry Coen; Ariel E Hight; Osama Tarabichi; Vivek V Kanumuri; Nicolas Vachicouras; Stéphanie P Lacour; Daniel J Lee; M Christian Brown
Journal:  J Assoc Res Otolaryngol       Date:  2022-04-05

4.  Recessed Traces for Planarized Passivation of Chronic Neural Microelectrodes.

Authors:  Nicholas F Nolta; Pejman Ghelich; Martin Han
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2019-07

5.  Fabrication and modeling of recessed traces for silicon-based neural microelectrodes.

Authors:  Nicholas F Nolta; Pejman Ghelich; Alpaslan Ersöz; Martin Han
Journal:  J Neural Eng       Date:  2020-10-08       Impact factor: 5.379

6.  3D Reconstruction of the Intracortical Volume Around a Hybrid Microelectrode Array.

Authors:  Aparna Nambiar; Nicholas F Nolta; Martin Han
Journal:  Front Neurosci       Date:  2019-04-24       Impact factor: 4.677

7.  Unprotected sidewalls of implantable silicon-based neural probes and conformal coating as a solution.

Authors:  Pejman Ghelich; Nicholas F Nolta; Martin Han
Journal:  Npj Mater Degrad       Date:  2021-02-10

8.  Configuring intracortical microelectrode arrays and stimulus parameters to minimize neuron loss during prolonged intracortical electrical stimulation.

Authors:  Douglas McCreery; Martin Han; Victor Pikov; Carol Miller
Journal:  Brain Stimul       Date:  2021-10-20       Impact factor: 8.955

9.  A portable neurostimulator circuit with anodic bias enhances stimulation injection capacity.

Authors:  Alpaslan Ersöz; Insoo Kim; Martin Han
Journal:  J Neural Eng       Date:  2022-10-05       Impact factor: 5.043

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.